| Rated Voltage (MAX) | 50V [AC/DC (effective value) 50Hz] | |
| Rated Current (MAX) | 0.5A | |
| Ambient Temperature Range | -25 ~ +85 | |
| Contact Resistance | 30 m MAX | Mate applicable FPC/FFC and measure by dry circuit, 20mV MAX, 10mA. |
| Insulation Resistance | 500 M MIN | Mate applicable FPC/FFC and apply 500V DC between adjacent terminal or ground. |
| Dielectric Strength | No Breakdown | Mate applicable FPC/FFC and apply 250V AC (virtual value) for 1 minute between adjacent terminal or ground. |
| Locking Force (MAX) | 1.96*n (N) | Insert and extract applicable FFC at the speed rate of 253mm/minute. |
| Withdrawal Force (MIN) | 0.49*n (N) | Insert and extract applicable FFC at the speed rate of 253mm/minute. |
| Terminal/Housing Retention Force (MIN) | 0.25N | Pull the terminal at the speed rate of 25 3mm per minute. |
| Contact Resistance (After Repeated Insertion/Withdrawal) | 60 m MAX | Insertion and withdrawal actuator up to 20 cycles at the speed rate of less than 10 cycles/minute. |
| Temperature Rise | 30 MAX | Carrying rated current load (UL 498). |
| Contact Resistance (After Vibration) | 60 m MAX | Vibration 10-55-10Hz/min, Amplitude: 1.5mm P-P, Duration: 2 hours in each X,Y,Z axes. DC 1mA current. |
| Discontinuity (After Vibration) | 1 ms MAX | Vibration 10-55-10Hz/min, Amplitude: 1.5mm P-P, Duration: 2 hours in each X,Y,Z axes. DC 1mA current. |
| Appearance (After Shock) | No Damage | 490m/s{50G}, 3 strokes in each X,Y,Z axes. DC 1mA current. |
| Discontinuity (After Shock) | 1 ms MAX | 490m/s{50G}, 3 strokes in each X,Y,Z axes. DC 1mA current. |
| Appearance (After Heat Resistance) | No Damage | 852, 96 hours. |
| Contact Resistance (After Heat Resistance) | 60 m MAX | 852, 96 hours. |
| Appearance (After Cold Resistance) | No Damage | -402, 96 hours. |
| Contact Resistance (After Cold Resistance) | 60 m MAX | -402, 96 hours. |
| Appearance (After Humidity) | No Damage | Temperature: 402, Relative Humidity: 90-95%, Duration: 96 Hours. |
| Contact Resistance (After Humidity) | 60 m MAX | Temperature: 402, Relative Humidity: 90-95%, Duration: 96 Hours. |
| Insulation Resistance (After Humidity) | 20 M MIN | Temperature: 402, Relative Humidity: 90-95%, Duration: 96 Hours. |
| Dielectric Strength (After Humidity) | Must meet 4.1.3 | Temperature: 402, Relative Humidity: 90-95%, Duration: 96 Hours. |
| Appearance (After Temperature Cycling) | No Damage | 5 cycles of: a) -553 30 minutes, b) 852 30 minutes. |
| Contact Resistance (After Temperature Cycling) | 60 m MAX | 5 cycles of: a) -553 30 minutes, b) 852 30 minutes. |
| Appearance (After Salt Spray) | No Damage, No Corrosion | 244 hours exposure to a salt spray from the 51% solution at 352. |
| Contact Resistance (After Salt Spray) | 60 m MAX | 244 hours exposure to a salt spray from the 51% solution at 352. |
| Contact Resistance (After SO2 Gas) | 60 m MAX | 24 hours exposure to 50 5ppm. SO2 gas at 402. |
| Appearance (After NH3 Gas) | No Damage | 40 minutes exposure to NH3 gas evaporating from 28% Ammonia solution. |
| Contact Resistance (After NH3 Gas) | 60 m MAX | 40 minutes exposure to NH3 gas evaporating from 28% Ammonia solution. |
| Solder Wetting | 95% or more coverage | Soldering Time: 20.5 sec. Soldering Temperature: 2455, 0.2 mm from terminal tip. |
| Appearance (After Soldering Heat Resistance) | No Damage, No Deformation | Soldering Time: 305 sec. Soldering Temperature: 2455. |