| IEC 60320-1 (C14) | PX0579, PX0580, PX0590, PX0596, PX0575, PX0595, PF0001, PF0002, PF0030, PF0033, PX0575/10/28, PX0575/10/PC, PX0580/28, PX0579/28, PX0580/PC, PX0580/PC/7, PF0001/48, PF0001/PC, PF0002/28, PF0030/28, PF0030/PC, PF0033/10/28 | Flange Fixing, Snap to Panel, PCB Mounting | 2.8/4.8/6.3mm Tabs, Screw Terminals, PC Spills | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +70C | -40C to +70C | <10m | >10 M | 5kV (Contact-Contact), 4kV (Contacts-Panel/Accessible Parts) |
| IEC 60320-1 (C14) - Fused | PF0001, PF0002, PF0030, PF0033, PF0006, PF0007, PF0011, PF0016 | Flange, Snap to Panel, PCB Mounting | Tabs, Screw Terminals, PC Spills | 10A | 250V AC | +70C | -40C to +70C | <10m (<15m incl. Fuseholder) | >10 M | 5.5kV (Contact-Contact), 4kV (Contacts-Panel) |
| IEC 60320-1 (C14) - Twin Fused | PF0030, PF0033 | Flange, Snap to Panel | Tabs, PC Spills | 10A | 250V AC | +70C | -20C to +70C | <15m (per Contact) | >10 M | 6kV (Contact-Contact), 5kV (Contacts-Panel) |
| IEC 60320-1 (C13, C15, C19) | PX0587, PX0588, PX0597, PX0587/SE, PX0585, PX0686, PX0686/SE, PX0685 | Cable Mounting, Side Entry, Right Angle | Screw Terminals | 10A, 16A | 250V AC | +70C | -40C to +70C | <10m | >10 M / >10 M | 4kV to 6kV |
| IEC 60320-1 (C15 & C16) - Hot Condition | PX0597, PX0590, PX0595 | Flange Mount, Snap Fit to Panel | Tabs, Screw Terminals | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +120C | -40C to +70C | <10m | >10 M | 4.5kV to 10kV |
| IEC 60320-1 (C18) - Class II | PX0690, PX0691, PX0705, PX0725 | Flange Mount, Snap Fit to Panel | Tabs, Screw Terminals, PC Spills | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +70C | -40C to +70C | <10m | >10 M | 4kV to 10kV |
| IEC 60320-1 (C18) - Class II Fused | PF0006, PF0007, PF0016 | Flange Mount, Snap Fit to Panel | Tabs | 10A | 250V AC | +70C | -40C to +70C | <10m (<15m incl. Fuseholder) | >10 M | 5.5kV (Contact-Contact), 4kV (Contacts-Panel) |
| IEC 60320-2-2 (F) - Class I | PX0716, PX0675, PX0695, PX0783, PX0793, PX0793/1 | Snap Fit to Panel, Flange Mount, PC Flange Rear Mount | Tabs, Screw Terminals, PC Spills | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +70C | -40C to +70C | <10m | >10 M | 4kV to 9kV |
| IEC 60320-2-2 (H) - Class II | PX0705, PX0725 | Flange Mount, Snap Fit to Panel | Tabs, PC Spills | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +70C | -40C to +70C | <10m | >10 M | 4kV to 9kV |
| IEC 60320-1 (C19 & C20) - Class I | PX0599, PX0596, PX0598 | Cable Mounting, Flange Mount, Snap Fit to Panel | 6.3mm or 4.8mm Tabs, Screw Terminals | 16A | 250V AC (UL/cUL: 20A, 250V AC) | +70C | -40C to +70C | N/A | >5M / >10 M | 1.5kV AC to 3kV AC |