Product Overview
The Anderson Power Saf-D-Grid connector system builds upon the established contact technology of SB and Powerpole connectors, offering enhanced features for DC power connections in higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide a safe and efficient power connection for both AC and DC currents, enabling greater power density within the footprint of IEC 620 C13/C14 connectors. They are ideal for applications requiring reliable power in renewable and alternative energy systems, ensuring system uptime.
Key Features and Benefits:
- Compact Design: Connects devices carrying up to 30A and 600V in the footprint of an IEC 620 C13/C14.
- High Power Density: Offers up to 40A and 600V DC or AC within the space of standard IEC 320 C13/14 connectors (limited to 10A and 250 VAC).
- Safety Features: Includes First Mate, Last Break Ground Contact for enhanced safety and Touch Safe / Shock Protection.
- Reliable Connection: Features an Integral Latch (T-Latch) to prevent accidental unmating and Hot Plug rating for current interruption.
- Arcing Protection: Housings contain arcs during mating/unmating under load.
- International Compliance: Meets safety requirements including UL 950 and IEC 60950.
Product Attributes
- Brand: Anderson Power
- Product Line: Saf-D-Grid
- Technology Basis: SB and Powerpole
- Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, IEC 61984, UL 817
- Materials: High Temp Nylon 30% Glass (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief.
- Environmental: RoHS compliant.
Technical Specifications
| Specification | Saf-D-Grid 400V Series | Saf-D-Grid 300V Series |
|---|---|---|
| Voltage Rating (AC/DC) | 600V (UL/CSA), 400V (IEC) | 600V (UL/CSA), 400V (IEC) |
| Current Rating (UL 1977) | See Table on Page 5 | See Table on Page 5 |
| Wire Range | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Operating Temperature | -20 to 105C (-4 to 176F) | -20 to 105C (-4 to 284F) |
| Durability | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Contact Retention | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention | 60 lb (267N) | 60 lb (267N) |
| Dielectric Withstanding Voltage | 3300V | 3300V |
| Creep and Clearance | 7.0 mm min | 7.0 mm min |
| Mechanical Shock | 50g (IEC 60512-4-6C) | 50g (IEC 60512-4-6C) |
| Vibration | 20g (IEC 60512-4-6d) | 20g (IEC 60512-4-6d) |
Receptacle Ratings and Approvals (Selected Models)
| Series | Wire Size | UL 1977 Current Interrupt (300V/400V) | IEC 61984 Current Interrupt (300V/400V) | Disconnect Current (600V) |
|---|---|---|---|---|
| SDG 300 Receptacle Key "A" | 14 AWG | 20A | 20A | 35A |
| SDG 300 Receptacle Key "C" | 10 AWG | 32A | 32A | 55A |
| SDG 400V Flush Mount | 14 AWG | 20A | 20A | 20A |
| SDG 400V Ultra Short | 14 AWG | 20A | 20A | 35A |
| SDG 400V Ultra Short | 10 AWG | 30A | 30A | 30A |
Cable Configurations (Selected Models)
| Part Number | Cable Type | Cordset Length | Voltage Rating (Disconnect AC/DC) | Current Rating (UL,CSA / IEC) | Temperature Rating |
|---|---|---|---|---|---|
| 2035KZ1-BK | Saf-D-Grid 400V 12 AWG ST | 1m | 600V | 25A | 105C |
| 2047KZ1-BK | Saf-D-Grid 400V 2.5mm H05VV-F | 1m | 300V | 25A / 25A | 70C |
| 2058KZ1-BK | Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F | 1m | 300V | 20A / 25A | 75C UL / 70C IEC |
| 2059KN1-BK | Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F to IEC 320 C14 | 1m | 250V | 15A / 10A | 70C |
| 2050KH1-BK | Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F to IEC 320 C20 | 1m | 250V | 16A / 16A | 70C |
| 2351-1200-10 | Saf-D-Grid 300V KEY B 12 AWG SJT | 1m | 300V | 20A | 90C |