power density Anderson Power 2007G2-BK connectors compatible with IEC 620 C13 C14 footprint standards
Anderson Power Saf-D-Grid Connectors
The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide safe and efficient power connections for both AC and DC currents up to 30A and 600V, fitting within the footprint of an IEC 620 C13/C14. This allows for greater power density compared to standard IEC 320 connectors. Key safety features include a first mate, last break ground contact, integral latch to prevent accidental unmating, hot plug rating for various loads, touch-safe design, and arcing protection. Saf-D-Grid is ideal for applications requiring reliable power in renewable energy systems and other demanding environments.
Product Attributes
- Brand: Anderson Power
- Product Line: Saf-D-Grid
- Legacy: Builds on SB and Powerpole contact technology
- Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984 (where applicable)
- Material (Housings): High Temp Nylon 30% Glass, UL94 V-0, Halogen Free; Polycarbonate UL94 V-0
- Material (Springs): Stainless Steel
- Material (Contacts): Copper/Silver Plate
- Material (Shield): Copper/Tin Plate
- Material (Cable/Strain Relief): Thermoplastic UL94 V-2
- Compliance: RoHS compliant
Technical Specifications
| Specification | Saf-D-Grid 400V | Saf-D-Grid 300V (AC Applications) |
|---|---|---|
| Voltage Rating (AC/DC) | 600V (UL) / 400V (IEC) | 600V (UL) / 400V (IEC) |
| Current Rating (UL 1977) | See Table on Page 5 | See Table on Page 5 |
| Wire Range | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Disconnect Current Interrupt | 600V (UL) / 400V (IEC) | 600V (UL) / 400V (IEC) |
| Dielectric Withstanding Voltage | 3300V | 3300V |
| Operating Temperature | -4 to 176F (-20 to 105C) | -4 to 284F (-20 to 105C) |
| Contact Retention | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention | 60 lb (267N) | 60 lb (267N) |
| Durability | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Max Wire Size (Receptacle) | 10 AWG (4.0 mm) | 10 AWG (4.0 mm) |
| Creep and Clearance | 7.0 mm min | 7.0 mm min |
| Mechanical Shock (IEC 60512-4-6C) | 50g | 50g |
| Vibration (IEC 60512-4-6d) | 20g | 20g |
Model Specific Ratings (Examples)
| Series | Wire Size | UL 1977 Current Rating (Amps) | IEC 61984 Current Rating (Amps) | Disconnect (600V) | Current Interrupt (300V/400V) |
|---|---|---|---|---|---|
| SDG 300 Receptacle Key "A" | 14 AWG | 35 | N/A | 25 | 20 |
| SDG 400V Flush Mount | 14 AWG | 20 | N/A | 20 | 20 |
| SDG 400V Ultra Short | 14 AWG | 21 | 25 | 20 | 20 |
| SDG 400V Ultra Short | 10 AWG | 30 | N/A | 30 | 30 |
Cable Configurations (Examples)
| Part Number | Connector 1 | Cable | Connector 2 | Length | Voltage Rating (Disconnect) | Voltage Rating (Current Interrupt) | Current Rating | Temperature Rating |
|---|---|---|---|---|---|---|---|---|
| 2031KZ1-BK | Saf-D-Grid 400V | 14 AWG ST | None | 1m | 600V | 400V | 16A | 105C |
| 2035KK2-BK | Saf-D-Grid 400V | 12 AWG ST | Saf-D-Grid 400V | 2m | 600V | 400V | 25A | 105C |
| 2047KZ1-BK | Saf-D-Grid 400V | 2.5mm H05VV-F | None | 1m | 300V | 300V | 25A | 70C |
| 2050KN3-BK | Saf-D-Grid 400V | 14 AWG SJT / 1.5mm H05VV-F | IEC 320 C14 | 3m | 250V | 250V | 15A / 10A | 70C |
| 2058KH2-BLUE-BK | Saf-D-Grid 400V | 12 AWG SJT / 2.5mm H05VV-F (BLUE) | IEC 320 C20 (BLUE) | 2m | 250V | 250V | 20A / 16A | 70C |
| 2352-1100-10 | Saf-D-Grid 300V KEY A | 14 AWG SJT | None | 1m | 300V | 300V | 16A | 90C |
2411220411_Anderson-Power-2007G2-BK_C3095940.pdf