compact Anderson Power 2002V1-BK connectors support up to 40A 600V dc ac with hot plug rating and shock protection
Anderson Power Saf-D-Grid Connectors
The Anderson Power Saf-D-Grid connector system builds on the proven contact technology of SB and Powerpole connectors, offering advanced features for DC and hybrid AC/DC power connections. Designed to meet the demands of higher voltage DC or hybrid systems, Saf-D-Grid provides a safe and efficient power connection in a compact footprint comparable to IEC 620 C13/C14 connectors. It is ideal for applications requiring higher power density, enabling up to 40A and 600V DC or AC within the same space as standard IEC 320 C13/14 connectors limited to 10A and 250 VAC. Saf-D-Grid is suitable for hazardous, low voltage applications and meets international safety requirements including UL 950 and IEC 60950.
Key Features and Benefits:
- First Mate, Last Break Ground Contact: Ensures a safe earthing path before power contacts engage.
- Integral Latch: Prevents accidental unmating, maintaining power to critical equipment.
- Hot Plug Rated: Capable of current interruption for both electronic (capacitive) and electrical (resistive) loads.
- Touch Safe / Shock Protection: Minimizes the risk of contact with hazardous voltages, passing UL & IEC finger probe tests.
- Arcing Protection: Housings contain arcs during mating/unmating under load, enhancing personnel safety.
- High Power Density: Delivers more voltage and current than similarly sized IEC 60320 connectors.
- Versatile Application: Suitable for both AC and DC current applications.
Product Attributes:
- Brand: Anderson Power
- Product Line: Saf-D-Grid
- Legacy: Builds on SB and Powerpole connector technology.
- Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, IEC 61984 (specific models), UL817 (cord sets).
- Materials: High Temp Nylon 30% Glass (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief.
- Environmental Compliance: RoHS compliant.
Technical Specifications:
| Specification | Saf-D-Grid 400V | Saf-D-Grid 300V / 300VAC |
|---|---|---|
| Contact Retention | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention | 60 lb (267N) | 60 lb (267N) |
| Durability | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Receptacle Max Wire Size | 10 AWG (4.0 mm) | N/A |
| Creep and Clearance | 7.0 mm min | 7.0 mm min |
| Max PCB Thickness | 0.093" (2.4 mm) | N/A |
| Mechanical Shock (IEC 60512-4-6C) | 50g | 50g |
| Vibration (IEC 60512-4-6d) | 20g | 20g |
| Voltage AC Disconnect (UL) | 600V | N/A |
| Voltage AC Disconnect (IEC) | 400V | N/A |
| Voltage DC Disconnect (UL) | 600V | N/A |
| Voltage DC Disconnect (IEC) | 400V | N/A |
| Voltage AC Current Interrupt (UL) | N/A | 600V |
| Voltage AC Current Interrupt (IEC) | N/A | 400V |
| Voltage DC Current Interrupt (UL) | N/A | 600V |
| Voltage DC Current Interrupt (IEC) | N/A | 400V |
| Wire Range | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Dielectric Withstanding Voltage | 3300V | 3300V |
| Operating Temperature | -4 to 176F (-20 to 105C) | -4 to 284F (-20 to 105C) |
| Fault Current Withstand (UL 467) | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) | 14 AWG, 300V, 4s |
| Housing Material | Polycarbonate UL94 V-0 (All Other Housings) | High Temp Nylon 30% Glass, UL94 V-0, Halogen Free (2006G and 2007G series receptacle housings) |
| Spring Material | Stainless Steel | Stainless Steel |
| Contact Material | Copper/Silver Plate | Copper/Silver Plate |
| Shield Material | Copper/Tin Plate | Copper/Tin Plate |
| Cable/Strain Relief Material | Thermoplastic UL94-V2 | Thermoplastic UL94-V2 |
Model Specific Ratings (Examples):
| Series | Wire Size | UL 1977 Current Rating (Amps) | Current Interrupt (300V/400V) (Amps) | Disconnect (600V) (Amps) |
|---|---|---|---|---|
| SDG 300 Receptacle Key "A" | 14 AWG | 35 | 20 | 25 |
| SDG 400V Flush Mount | 14 AWG | 20 | 20 | 20 |
| SDG 400V Ultra Short | 14 AWG | 21 | 20 | 25 |
| SDG 400V Ultra Short | 10 AWG | 30 | 30 | 30 |
| SAF-D-GRID 400 TO C14 | 14 AWG SJT / 1.5mm H05VV-F | 15A / 10A | 250V | 250V |
| SAF-D-GRID 400 TO C20 | 12 AWG SJT / 2.5mm H05VV-F | 20A / 16A | 250V | 250V |
| NORTH AMERICAN 300V KEY A | 14 AWG SJT | 16A | 300V | 300V |
Cable Configurations:
Available in North American, Metric, Universal, and IEC 320 configurations with various cable types (SJT, H05VV-F), lengths, and voltage/current ratings.
Tooling:
Anderson assembly tooling is required for UL, CSA & other safety agency compliance. Use of unapproved tooling will void connector warranty. Automated and hand tooling are available.
Note: All data subject to change without notice. Refer to product drawings for additional information.
2411220411_Anderson-Power-2002V1-BK_C3096012.pdf