Specifications
Mfr. Part #:
2002G5-GRY-BK
Model Number:
2002G5-GRY-BK
Introduction

Product Overview

The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for DC power connections in higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide a safe and efficient power connection for both AC and DC currents, enabling greater power density within the footprint of an IEC 620 C13/C14. Key safety features include a First Mate, Last Break ground contact, integral latch to prevent accidental unmating, hot-plug rating, touch-safe design, and arcing protection, making it ideal for applications where system uptime and safety are critical, particularly in renewable and alternative energy sectors.

Product Attributes

  • Brand: Anderson Power
  • Product Line: Saf-D-Grid
  • Legacy: Builds on SB and Powerpole contact technology
  • Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984
  • Materials: High Temp Nylon 30% Glass (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief
  • Safety Features: First Mate, Last Break Ground Contact, Integral Latch, Hot Plug Rated, Touch Safe / Shock Protection, Arcing Protection
  • Origin: USA (Headquarters)

Technical Specifications

Specification Saf-D-Grid 400V Saf-D-Grid 300VAC
AC/DC Current Rating Up to 30A / 600V DC or AC N/A (Targets AC applications)
Voltage Rating Up to 600V DC or AC Up to 600V AC
IEC Footprint Compatibility IEC 620 C13/C14 IEC 620 C13/C14
UL Rated Disconnect Up to 400V and 30A N/A
Contact Retention 20 lb (89N) 20 lb (89N)
Plug Latch Retention 20 lb (89N) 20 lb (89N)
Panel Latch Retention 60 lb (267N) 60 lb (267N)
Durability 5,000 Cycles (no load) 5,000 Cycles (no load)
Receptacle Max Wire Size 10 AWG (4.0 mm) N/A
Creep and Clearance 7.0 mm min 7.0 mm min
Max PCB Thickness 0.093" (2.4 mm) (for PCB contacts only) N/A
Mechanical Shock (IEC 60512-4-6C) 50g 50g
Vibration (IEC 60512-4-6d) 20g 20g
AC Disconnect Voltage 600V (UL 1977/CSA 22.2), 400V (IEC) 600V (UL 1977/CSA 22.2), 400V (IEC)
DC Disconnect Voltage 600V (UL 1977/CSA 22.2), 400V (IEC) 600V (UL 1977/CSA 22.2), 400V (IEC)
Current Rating (UL 1977) See Table on Page 5 See Table on Page 5
Wire Range 10 AWG to 18 AWG (0.75 mm to 5.5 mm) 10 AWG to 18 AWG (0.75 mm to 5.5 mm)
Dielectric Withstanding Voltage 3300V 3300V
Operating Temperature -4 to 176F (-20 to 105C) -4 to 284F (-20 to 105C)
Fault Current Withstand (UL 467) 14 AWG, 300V, 4s (10 AWG, 750V, 4s) 14 AWG, 300V, 4s

Specific Models and Ratings (Excerpt)

Series Key Wire Size UL 1977 Rating (Amps) IEC 61984 Rating (Amps) Part Number Example
SDG 300 Receptacle A 14 AWG 35 (Disconnect) / 20 (Interrupt) 25 (Disconnect) / 20 (Interrupt) 2316G
SDG 400V Flush Mount N/A 18 AWG 18 (Disconnect) / 12 (Interrupt) 18 (Disconnect) / 12 (Interrupt) 2002
SDG 400V Ultra Short C 10 AWG 30 (Disconnect) / 30 (Interrupt) 32 (Interrupt) 2007
North American 600V Cable N/A 10 AWG ST 30A (Current Interrupt) N/A 2038KK6-BK
Metric Cable N/A 4.0mm H05V2V2-F 32A (Disconnect) / 30A (Interrupt) 300V (Current Interrupt) 2049KK6-BK
Universal Cable N/A 12 AWG SJT / 2.5mm H05VV-F 20A (UL,CSA) / 25A (IEC) 20A (UL,CSA) / 25A (IEC) 2058KK6-BK
Saf-D-Grid 400 to C14 N/A 14 AWG SJT / 1.5mm H05VV-F 15A (UL,CSA) / 10A (IEC) 250V (Disconnect) / 250V (Interrupt) 2059KN3-BLUE-BK
Saf-D-Grid 400 to C20 N/A 12 AWG SJT / 2.5mm H05VV-F 20A (UL,CSA) / 16A (IEC) 250V (Disconnect) / 250V (Interrupt) 2058KH3-RED-BK
300V Keyed for AC Usage A 14 AWG SJT 16A 300V (Current Interrupt) 2352-1100-30