Safe Anderson Power 2005V1 connectors built to meet international safety and certification standards
Anderson Power Saf-D-Grid Connectors
Product Overview
The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering advanced features for Direct Current (DC) and hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide a safe and efficient power connection for applications up to 30A and 600V, fitting within the footprint of an IEC 620 C13/C14. Key features include First Mate, Last Break ground contact for enhanced safety, an integral latch to prevent accidental unmating, hot plug rating for current interruption of various loads, touch-safe design for shock protection, and arcing protection within the housings. These connectors enable greater power density by delivering higher voltage and current within a compact IEC 60320 C13/14 sized system.
Product Attributes
- Brand: Anderson Power
- Product Line: Saf-D-Grid
- Legacy: Builds on SB and Powerpole contact technology
- Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984
- Materials: High Temp Nylon 30% Glass (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief
- Safety Features: First Mate, Last Break Ground Contact, Integral Latch, Hot Plug Rated, Touch Safe / Shock Protection, Arcing Protection
- Color: Black (unless otherwise specified for cable assemblies)
Technical Specifications
| Specification | Saf-D-Grid 400V | Saf-D-Grid 300VAC |
|---|---|---|
| Contact Retention | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention | 60 lb (267N) | 60 lb (267N) |
| Durability | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Receptacle Max Wire Size | 10 AWG (4.0 mm) | N/A |
| Creep and Clearance (min) | 7.0 mm | 7.0 mm |
| Max PCB Thickness (for PCB contacts only) | 0.093" (2.4 mm) | N/A |
| Mechanical Shock (IEC 60512-4-6C) | 50g | 50g |
| Vibration (IEC 60512-4-6d) | 20g | 20g |
| Voltage AC Disconnect (UL) | 600V (UL 1977/CSA 22.2) | 600V (UL 1977/CSA 22.2) |
| Voltage AC Disconnect (IEC) | 400V (IEC) | 400V (IEC) |
| Voltage DC Disconnect (UL) | 600V (UL 1977/CSA 22.2) | 600V (UL 1977/CSA 22.2) |
| Voltage DC Disconnect (IEC) | 400V (IEC) | 400V (IEC) |
| Wire Range | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Dielectric Withstanding Voltage | 3300V | 3300V |
| Operating Temperature | -4 to 176F (-20 to 105C) | -4 to 284F (-20 to 105C) |
| Fault Current Withstand (UL 467) | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) |
Receptacle Ratings and Approvals (Examples)
| Series | Wire Size | UL 1977 Current | Current Interrupt (IEC) | Disconnect (IEC) |
|---|---|---|---|---|
| SDG 400V Ultra Short (2006) | 14 AWG | 20A | 20A | 25A |
| SDG 400V Ultra Short (2007) | 10 AWG | 30A | 30A | 30A |
| SDG 300 Receptacle Key "C" | 10 AWG | 55A | 32A | 32A |
North American 600V Cable Configurations (Examples)
| Part Number | Cable | Cordset Length | Voltage Rating Disconnect (AC) | Current Rating |
|---|---|---|---|---|
| 2035KZ1-BK | 12 AWG ST | 1m | 600V | 25A |
| 2038KK6-BK | 10 AWG ST | 6m | 600V | 30A |
Metric Cable Configurations (Examples)
| Part Number | Cable | Cordset Length | Voltage Rating Disconnect (AC/DC) | Current Rating |
|---|---|---|---|---|
| 2047KZ3-BK | 2.5mm H05VV-F | 3m | 300V | 25A |
| 2049KK6-BK | 4.0mm H05V2V2-F | 6m | 300V | 30A (Current Interrupt) |
Universal Cable Configurations (Examples)
| Part Number | Cable | Cordset Length | Current Rating (UL,CSA / IEC) |
|---|---|---|---|
| 2058KZ2-BK | 12 AWG SJT / 2.5mm H05VV-F | 2m | 20A / 25A |
| 2050KK6-BK | 14 AWG SJT / 1.5mm H05VV-F | 6m | 16A / 16A |
Saf-D-Grid 400 to C14 Cable Configurations (Examples)
| Part Number | Cable | Cordset Length | Voltage Rating Disconnect (AC) | Current Rating (UL,CSA / IEC) |
|---|---|---|---|---|
| 2059KN2-BK | 14 AWG SJT / 1.5mm H05VV-F | 2m | 250V | 15A / 10A |
| 2059KN3-BLUE-BK | 14 AWG SJT / 1.5mm H05VV-F (BLUE) | 3m | 250V | 15A / 10A |
Saf-D-Grid 400 to C20 Cable Configurations (Examples)
| Part Number | Cable | Cordset Length | Voltage Rating Disconnect (AC) | Current Rating (UL,CSA / IEC) |
|---|---|---|---|---|
| 2050KH3-BK | 14 AWG SJT / 1.5mm H05VV-F | 3m | 250V | 16A / 16A |
| 2058KH4R5-RED-BK | 12 AWG SJT / 2.5mm H05VV-F (RED) | 4.5m | 250V | 20A / 16A |
North American 300V Configurations with Keys (Examples)
| Part Number | Key Configuration | Cable | Cordset Length | Current Rating |
|---|---|---|---|---|
| 2352-1100-20 | KEY A | 14 AWG SJT | 2m | 16A |
| 2351-1200-60 | KEY B | 12 AWG SJT | 6m | 20A |
| 2350-1300-30 | KEY C | 10 AWG SJT | 3m | 30A |
2411220411_Anderson-Power-2005V1_C3095920.pdf