The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors enable greater power density by allowing up to 40A and 600V DC or AC within the same footprint as IEC 620 C13/C14 connectors, which are limited to 10A and 250 VAC. These connectors are suitable for hazardous, low voltage applications and are rated for current interruption for both electronic and electrical loads. Saf-D-Grid provides safety through a first-mate, last-break ground contact and an integral latch to prevent accidental unmating. They are ideal for renewable and alternative energy sources, ensuring system uptime.

Product Attributes

  • Brand: Anderson Power
  • Product Line: Saf-D-Grid
  • Legacy: Builds on SB and Powerpole contact technology
  • Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984
  • Safety Features: First Mate, Last Break Ground Contact, Integral Latch, Hot Plug Rated, Touch Safe / Shock Protection, Arcing Protection
  • Materials: High Temp Nylon 30% Glass (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief
  • Compliance: RoHS compliant

Technical Specifications

Specification Saf-D-Grid 400V Saf-D-Grid 300V (AC Applications)
Voltage Rating (AC/DC): 600V (UL/CSA), 400V (IEC) 600V (UL/CSA), 400V (IEC)
Current Rating (UL 1977): See Table on Page 5 See Table on Page 5
Current Interrupt (AC/DC): 600V (UL/CSA), 400V (IEC) 600V (UL/CSA), 400V (IEC)
Wire Range: 10 AWG to 18 AWG (0.75 mm to 5.5 mm) 10 AWG to 18 AWG (0.75 mm to 5.5 mm)
Operating Temperature: -4 to 176F (-20 to 105C) -4 to 284F (-20 to 105C)
Contact Retention: 20 lb (89N) 20 lb (89N)
Plug Latch Retention: 20 lb (89N) 20 lb (89N)
Panel Latch Retention: 60 lb (267N) 60 lb (267N)
Durability: 5,000 Cycles (no load) 5,000 Cycles (no load)
Receptacle Max Wire Size: 10 AWG (4.0 mm) N/A
Creep and Clearance: 7.0 mm min 7.0 mm min
Max PCB Thickness (PCB contacts): 0.093" (2.4 mm) N/A
Mechanical Shock (IEC 60512-4-6C): 50g 50g
Vibration (IEC 60512-4-6d): 20g 20g
Dielectric Withstanding Voltage: 3300V 3300V
Fault Current Withstand (UL 467): 14 AWG, 300V, 4s (10 AWG, 750V, 4s) 14 AWG, 300V, 4s (10 AWG, 750V, 4s)