Home > Products > Plugs and Receptacles >Plugs and Receptacles > power connection solutions featuring Anderson Power 2006G4 connectors for DC and hybrid AC DC systems

power connection solutions featuring Anderson Power 2006G4 connectors for DC and hybrid AC DC systems

Manufacturer:
Anderson Power
Description:
Plugs and Receptacles RoHS
Category:
Plugs and Receptacles/Plugs and Receptacles
Specifications
Mfr. Part #:
2006G4
Model Number:
2006G4
Introduction

Anderson Power Saf-D-Grid Connectors

Product Overview
The Anderson Power Saf-D-Grid connector system builds upon the established contact technology of SB and Powerpole connectors, offering advanced features for DC power connections in higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide a safe and efficient power connection for both AC and DC currents, enabling greater power density within the footprint of an IEC 620 C13/C14. Key features include a first-mate, last-break ground contact, integral latch for secure connections, hot-plug rating for various loads, touch-safe design for shock protection, and arcing protection within the housings. These connectors are ideal for applications requiring reliable power in systems where renewable and alternative energy sources are utilized, ensuring system uptime and efficient space utilization.

Product Attributes

  • Brand: Anderson Power
  • Product Line: Saf-D-Grid
  • Legacy Technology: Builds on SB and Powerpole contact technology
  • Certifications: UL rated for disconnect up to 400V and 30A, Meets UL 950 and IEC 60950, RoHS compliant
  • Material (Housings): High Temp Nylon 30% Glass, UL94 V-0, Halogen Free (400V series); Polycarbonate UL94 V-0 (All Other Housings)
  • Material (Springs): Stainless Steel
  • Material (Contacts): Copper/Silver Plate
  • Material (Shield): Copper/Tin Plate
  • Material (Cable/Strain Relief): Thermoplastic UL94 V-2

Technical Specifications

Specification Saf-D-Grid 400V Series Saf-D-Grid 300V Series
AC Voltage Rating (Disconnect): 600V (UL 1977/CSA 22.2)
400V (IEC)
600V (UL 1977/CSA 22.2)
400V (IEC)
DC Voltage Rating (Disconnect): 600V (UL 1977/CSA 22.2)
400V (IEC)
600V (UL 1977/CSA 22.2)
400V (IEC)
Current Rating (UL 1977): See Table on Page 5 See Table on Page 5
Wire Range: 10 AWG to 18 AWG (0.75 mm to 5.5 mm) 10 AWG to 18 AWG (0.75 mm to 5.5 mm)
Dielectric Withstanding Voltage: 3300V 3300V
Operating Temperature: -4 to 176F (-20 to 105C) -4 to 284F (-20 to 105C)
Contact Retention: 20 lb (89N) 20 lb (89N)
Plug Latch Retention: 20 lb (89N) 20 lb (89N)
Panel Latch Retention: 60 lb (267N) 60 lb (267N)
Durability: 5,000 Cycles (no load) 5,000 Cycles (no load)
Receptacle Max Wire Size: 10 AWG (4.0 mm) N/A
Creep and Clearance: 7.0 mm min 7.0 mm min
Max PCB Thickness (PCB contacts only): 0.093" (2.4 mm) N/A
Mechanical Shock (IEC 60512-4-6C): 50g 50g
Vibration (IEC 60512-4-6d): 20g 20g

Connector Ratings and Approvals (Example: SDG 300 Receptacle Key "A")

Series Wire Size UL 1977 CNR IEC 61984 Current Interrupt (300V/400V) UL 1977 Current Interrupt (300V/400V) CNR Current Interrupt (300V/400V) IEC 61984
SDG 300 Receptacle Key "A" 14 AWG 35A 25A N/A 20A 20A N/A
SDG 300 Receptacle Key "A" 12 AWG 35A 25A N/A 20A 20A N/A

Cable Configurations (Examples)

Part Number Connector 1 Cable Connector 2 Cordset Length Voltage Rating (Disconnect) Current Rating (UL,CSA / IEC) Temperature Rating
2035KZ1-BK Saf-D-Grid 400V 12 AWG ST None 1m 600V 25A 105C
2047KK2-BK Saf-D-Grid 400V 2.5mm H05VV-F Saf-D-Grid 400V 2m 300V 25A 70C
2058KH3-BLUE-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F (BLUE) IEC 320 C20 (BLUE) 3m 250V 20A / 16A 70C
2352-1100-10 Saf-D-Grid 300V KEY A 14 AWG SJT None 1m 300V 16A 90C

2411220411_Anderson-Power-2006G4_C3095836.pdf
Send RFQ
Stock:
MOQ: