Safe Power Solutions Anderson Power 2006G3-NC-BK Connector with Touch Safe Design and Integral Latch
Anderson Power Saf-D-Grid Connectors
Product Overview
The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for high-voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide a safe and efficient power connection for both AC and DC currents, enabling greater power density within the compact footprint of an IEC 620 C13/C14. Key features include a first-mate, last-break ground contact for enhanced safety, an integral latch to prevent accidental unmating, hot-plug rating for current interruption, touch-safe design, and arc containment within the housing. These connectors are ideal for applications where renewable and alternative energy sources are critical for system uptime.
Product Attributes
- Brand: Anderson Power
- Product Line: Saf-D-Grid
- Legacy: Builds on SB and Powerpole contact technology
- Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984
- Material (Housings): High Temp Nylon 30% Glass, UL94 V-0, Halogen Free; Polycarbonate UL94 V-0
- Material (Springs): Stainless Steel
- Material (Contacts): Copper/Silver Plate
- Material (Shield): Copper/Tin Plate
- Material (Cable/Strain Relief): Thermoplastic UL94 V-2
- RoHS Compliant: Yes
Technical Specifications
| Specification | Saf-D-Grid 400V | Saf-D-Grid 300V |
|---|---|---|
| Contact Retention | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention | 60 lb (267N) | 60 lb (267N) |
| Durability | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Receptacle Max Wire Size | 10 AWG (4.0 mm) | N/A |
| Creep and Clearance | 7.0 mm min | 7.0 mm min |
| Max PCB Thickness | 0.093" (2.4 mm) | N/A |
| Mechanical Shock (IEC 60512-4-6C) | 50g | 50g |
| Vibration (IEC 60512-4-6d) | 20g | 20g |
| Voltage AC Disconnect (UL/CSA) | 600V | N/A |
| Voltage AC Disconnect (IEC) | 400V | 400V |
| Voltage DC Disconnect (UL/CSA) | 600V | 600V |
| Voltage DC Disconnect (IEC) | 400V | 400V |
| Wire Range | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Dielectric Withstanding Voltage | 3300V | 3300V |
| Operating Temperature | -4 to 176F (-20 to 105C) | -4 to 284F (-20 to 105C) |
| Fault Current Withstand (UL 467) | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) | 14 AWG, 300V, 4s |
Receptacle Connector Ratings and Approvals
| Series | Wire Size | UL 1977 Current (Amps) | Disconnect (600V) | Current Interrupt (300V/400V) |
|---|---|---|---|---|
| SDG 400V Flush Mount | 18 AWG | 18 | 12 A | 12 A |
| SDG 400V Flush Mount | 14 AWG | 20 | 20 A | 20 A |
| SDG 400V Flush Mount | 12 AWG | 25 | 25 A | 25 A |
| SDG 400V Ultra Short | 14 AWG | 21 | 13 A | 20 A |
| SDG 400V Ultra Short | 12 AWG | 25 | 25 A | 25 A |
| SDG 400V Ultra Short | 10 AWG | 30 | 30 A | 30 A |
Cable Configurations
North American 600V Cable Configurations:
| Part Number | Cable | Length | Voltage Rating Disconnect (AC) | Current Rating |
|---|---|---|---|---|
| 2031KZ1-BK | 14 AWG ST | 1m | 600V | 16A |
| 2035KZ1-BK | 12 AWG ST | 1m | 600V | 25A |
| 2038KZ1-BK | 10 AWG ST | 1m | 600V | 30A |
Metric Cable Configurations:
| Part Number | Cable | Length | Voltage Rating Disconnect (AC/DC) | Current Rating |
|---|---|---|---|---|
| 2041KZ1-BK | 1.5mm H05VV-F | 1m | 300V | 16A |
| 2047KZ1-BK | 2.5mm H05VV-F | 1m | 300V | 25A |
| 2049KZ2-BK | 4.0mm H05V2V2-F | 2m | 300V | 32A (Disconnect) / 30A (Interrupt) |
Universal Cable Configurations:
| Part Number | Cable | Length | Voltage Rating Disconnect (AC/DC) | Current Rating (UL,CSA / IEC) |
|---|---|---|---|---|
| 2050KZ1-BK | 14 AWG SJT / 1.5mm H05VV-F | 1m | 300V | 16A / 16A |
| 2058KZ1-BK | 12 AWG SJT / 2.5mm H05VV-F | 1m | 300V | 20A / 25A |
Saf-D-Grid 400 to C14 Cable Configurations:
| Part Number | Cable | Connector 2 | Length | Current Rating (UL,CSA / IEC) |
|---|---|---|---|---|
| 2059KN1-BK | 14 AWG SJT / 1.5mm H05VV-F | IEC 320 C14 | 1m | 15A / 10A |
Saf-D-Grid 400 to C20 Cable Configurations:
| Part Number | Cable | Connector 2 | Length | Current Rating (UL,CSA / IEC) |
|---|---|---|---|---|
| 2050KH1-BK | 14 AWG SJT / 1.5mm H05VV-F | IEC 320 C20 | 1m | 16A / 16A |
| 2058KH1-BK | 12 AWG SJT / 2.5mm H05VV-F | IEC 320 C20 | 1m | 16A / 16A |
North American 300V Cable Configurations (with Keys for AC Usage):
| Part Number | Key Configuration | Cable | Length | Current Rating |
|---|---|---|---|---|
| 2352-1100-10 | KEY A | 14 AWG SJT | 1m | 16A |
| 2352-1200-10 | KEY B | 14 AWG SJT | 1m | 16A |
| 2351-1111-20 | KEY A | 12 AWG SJT | 2m | 20A |
| 2351-1200-10 | KEY B | 12 AWG SJT | 1m | 20A |
| 2350-1300-10 | KEY C | 10 AWG SJT | 1m | 30A |
Tooling Note: Anderson recommended tooling is required for UL, CSA & other safety agency compliance. Use of unapproved tooling will void connector warranty.
2411220411_Anderson-Power-2006G3-NC-BK_C3095711.pdf