Home > Products > Plugs and Receptacles >Plugs and Receptacles > Safe Power Solutions Anderson Power 2006G3-NC-BK Connector with Touch Safe Design and Integral Latch

Safe Power Solutions Anderson Power 2006G3-NC-BK Connector with Touch Safe Design and Integral Latch

Manufacturer:
Anderson Power
Description:
Plugs and Receptacles RoHS
Category:
Plugs and Receptacles/Plugs and Receptacles
Specifications
Mfr. Part #:
2006G3-NC-BK
Model Number:
2006G3-NC-BK
Introduction

Anderson Power Saf-D-Grid Connectors

Product Overview

The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for high-voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide a safe and efficient power connection for both AC and DC currents, enabling greater power density within the compact footprint of an IEC 620 C13/C14. Key features include a first-mate, last-break ground contact for enhanced safety, an integral latch to prevent accidental unmating, hot-plug rating for current interruption, touch-safe design, and arc containment within the housing. These connectors are ideal for applications where renewable and alternative energy sources are critical for system uptime.

Product Attributes

  • Brand: Anderson Power
  • Product Line: Saf-D-Grid
  • Legacy: Builds on SB and Powerpole contact technology
  • Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984
  • Material (Housings): High Temp Nylon 30% Glass, UL94 V-0, Halogen Free; Polycarbonate UL94 V-0
  • Material (Springs): Stainless Steel
  • Material (Contacts): Copper/Silver Plate
  • Material (Shield): Copper/Tin Plate
  • Material (Cable/Strain Relief): Thermoplastic UL94 V-2
  • RoHS Compliant: Yes

Technical Specifications

Specification Saf-D-Grid 400V Saf-D-Grid 300V
Contact Retention 20 lb (89N) 20 lb (89N)
Plug Latch Retention 20 lb (89N) 20 lb (89N)
Panel Latch Retention 60 lb (267N) 60 lb (267N)
Durability 5,000 Cycles (no load) 5,000 Cycles (no load)
Receptacle Max Wire Size 10 AWG (4.0 mm) N/A
Creep and Clearance 7.0 mm min 7.0 mm min
Max PCB Thickness 0.093" (2.4 mm) N/A
Mechanical Shock (IEC 60512-4-6C) 50g 50g
Vibration (IEC 60512-4-6d) 20g 20g
Voltage AC Disconnect (UL/CSA) 600V N/A
Voltage AC Disconnect (IEC) 400V 400V
Voltage DC Disconnect (UL/CSA) 600V 600V
Voltage DC Disconnect (IEC) 400V 400V
Wire Range 10 AWG to 18 AWG (0.75 mm to 5.5 mm) 10 AWG to 18 AWG (0.75 mm to 5.5 mm)
Dielectric Withstanding Voltage 3300V 3300V
Operating Temperature -4 to 176F (-20 to 105C) -4 to 284F (-20 to 105C)
Fault Current Withstand (UL 467) 14 AWG, 300V, 4s (10 AWG, 750V, 4s) 14 AWG, 300V, 4s

Receptacle Connector Ratings and Approvals

Series Wire Size UL 1977 Current (Amps) Disconnect (600V) Current Interrupt (300V/400V)
SDG 400V Flush Mount 18 AWG 18 12 A 12 A
SDG 400V Flush Mount 14 AWG 20 20 A 20 A
SDG 400V Flush Mount 12 AWG 25 25 A 25 A
SDG 400V Ultra Short 14 AWG 21 13 A 20 A
SDG 400V Ultra Short 12 AWG 25 25 A 25 A
SDG 400V Ultra Short 10 AWG 30 30 A 30 A

Cable Configurations

North American 600V Cable Configurations:

Part Number Cable Length Voltage Rating Disconnect (AC) Current Rating
2031KZ1-BK 14 AWG ST 1m 600V 16A
2035KZ1-BK 12 AWG ST 1m 600V 25A
2038KZ1-BK 10 AWG ST 1m 600V 30A

Metric Cable Configurations:

Part Number Cable Length Voltage Rating Disconnect (AC/DC) Current Rating
2041KZ1-BK 1.5mm H05VV-F 1m 300V 16A
2047KZ1-BK 2.5mm H05VV-F 1m 300V 25A
2049KZ2-BK 4.0mm H05V2V2-F 2m 300V 32A (Disconnect) / 30A (Interrupt)

Universal Cable Configurations:

Part Number Cable Length Voltage Rating Disconnect (AC/DC) Current Rating (UL,CSA / IEC)
2050KZ1-BK 14 AWG SJT / 1.5mm H05VV-F 1m 300V 16A / 16A
2058KZ1-BK 12 AWG SJT / 2.5mm H05VV-F 1m 300V 20A / 25A

Saf-D-Grid 400 to C14 Cable Configurations:

Part Number Cable Connector 2 Length Current Rating (UL,CSA / IEC)
2059KN1-BK 14 AWG SJT / 1.5mm H05VV-F IEC 320 C14 1m 15A / 10A

Saf-D-Grid 400 to C20 Cable Configurations:

Part Number Cable Connector 2 Length Current Rating (UL,CSA / IEC)
2050KH1-BK 14 AWG SJT / 1.5mm H05VV-F IEC 320 C20 1m 16A / 16A
2058KH1-BK 12 AWG SJT / 2.5mm H05VV-F IEC 320 C20 1m 16A / 16A

North American 300V Cable Configurations (with Keys for AC Usage):

Part Number Key Configuration Cable Length Current Rating
2352-1100-10 KEY A 14 AWG SJT 1m 16A
2352-1200-10 KEY B 14 AWG SJT 1m 16A
2351-1111-20 KEY A 12 AWG SJT 2m 20A
2351-1200-10 KEY B 12 AWG SJT 1m 20A
2350-1300-10 KEY C 10 AWG SJT 1m 30A

Tooling Note: Anderson recommended tooling is required for UL, CSA & other safety agency compliance. Use of unapproved tooling will void connector warranty.


2411220411_Anderson-Power-2006G3-NC-BK_C3095711.pdf

Send RFQ
Stock:
MOQ: