Specifications
Mfr. Part #:
2002V2-BK
Model Number:
2002V2-BK
Introduction

Anderson Power Saf-D-Grid Connectors

Product Overview

The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for DC power connections in higher voltage or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide a safe and efficient power connection for both AC and DC currents, enabling greater power density within the footprint of an IEC 620 C13/C14. Key safety features include First Mate, Last Break ground contact, an integral latch to prevent accidental unmating, hot plug rating for various loads, touch-safe design, and arc containment within the housings. These connectors are ideal for applications where renewable and alternative energy sources are critical for system uptime, ensuring reliable power delivery.

Product Attributes

  • Brand: Anderson Power
  • Product Line: Saf-D-Grid
  • Legacy: Builds on SB and Powerpole contact technology
  • Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984
  • Materials: High Temp Nylon 30% Glass (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief
  • Keying: Single keying for 400V series (DC/AC); Multiple mechanical keys for 300V series (AC/DC)

Technical Specifications

Specification Saf-D-Grid 400V Saf-D-Grid 300V
AC Voltage Rating 600V (UL) / 400V (IEC) 600V (UL) / 400V (IEC)
DC Voltage Rating 600V (UL) / 400V (IEC) 600V (UL) / 400V (IEC)
Current Rating (UL 1977) See Table on Page 5 See Table on Page 5
Wire Range 10 AWG to 18 AWG (0.75 mm to 5.5 mm) 10 AWG to 18 AWG (0.75 mm to 5.5 mm)
Dielectric Withstanding Voltage 3300V 3300V
Operating Temperature -20 to 105C (-4 to 284F) -20 to 105C (-4 to 176F)
Contact Retention 20 lb (89N) 20 lb (89N)
Plug Latch Retention 20 lb (89N) 20 lb (89N)
Panel Latch Retention 60 lb (267N) 60 lb (267N)
Durability 5,000 Cycles (no load) 5,000 Cycles (no load)
Max Wire Size (Receptacle) 10 AWG (4.0 mm) 10 AWG (4.0 mm)
Creep and Clearance 7.0 mm min 7.0 mm min
Max PCB Thickness (PCB contacts) 0.093" (2.4 mm) N/A
Mechanical Shock (IEC 60512-4-6C) 50g 50g
Vibration (IEC 60512-4-6d) 20g 20g
Fault Current Withstand (UL 467) 14 AWG, 300V, 4s (10 AWG, 750V, 4s) 14 AWG, 300V, 4s (10 AWG, 750V, 4s)

Receptacle Connector Ratings and Approvals

Series Wire Size UL 1977 Current (Amps) Disconnect (600V) Current Interrupt (300V/400V) IEC 61984 Current (Amps)
SDG 300 Receptacle Key "A" 14 AWG 35 25 20 N/A
SDG 300 Receptacle Key "A" 12 AWG 35 25 20 N/A
SDG 300 Receptacle Key "B" 14 AWG 35 25 20 N/A
SDG 300 Receptacle Key "B" 12 AWG 35 25 20 N/A
SDG 300 Receptacle Key "C" 10 AWG 55 38 32 N/A
SDG 400V Flush Mount 18 AWG 18 12 12 N/A
SDG 400V Flush Mount 16 AWG 18 18 14 N/A
SDG 400V Flush Mount 14 AWG 20 20 20 N/A
SDG 400V Flush Mount 12 AWG 25 25 25 N/A
SDG 400V Flush Mount 1.5mm H05VV-F N/A N/A 16 16
SDG 400V Flush Mount 2.5mm H05VV-F N/A N/A 25 25
SDG 400V Short 18 AWG 18 12 12 N/A
SDG 400V Short 16 AWG 18 18 14 N/A
SDG 400V Short 14 AWG 20 20 20 N/A
SDG 400V Short 12 AWG 25 25 25 N/A
SDG 400V Short 1.5mm H05VV-F N/A N/A 16 16
SDG 400V Short 2.5mm H05VV-F N/A N/A 25 25
SDG 400V Ultra Short 18 AWG 35 25 12 12
SDG 400V Ultra Short 16 AWG TBD TBD TBD N/A
SDG 400V Ultra Short 14 AWG 21 13 20 20
SDG 400V Ultra Short 12 AWG 25 25 25 N/A
SDG 400V Ultra Short 10 AWG 30 30 30 N/A
SDG 400V Ultra Short 1.5mm H05VV-F N/A N/A 16 16
SDG 400V Ultra Short 2.5mm H05VV-F N/A N/A 25 25
SDG 400V Ultra Short 4.0mm H05VV-F N/A N/A 30 32

Cable Configurations

North American 600V Cable Configurations

Part Number Connector 1 Cable Connector 2 Cordset Length Voltage Rating Disconnect (AC) Voltage Rating Current Interrupt (AC) Current Rating Maximum Temperature
2031KZ1-BK Saf-D-Grid 400V 14 AWG ST None 1m 600V 400V 16A 105C
2035KZ1-BK Saf-D-Grid 400V 12 AWG ST None 1m 600V 400V 25A 105C
2036KZ1-BK Saf-D-Grid 400V 16 AWG ST None 1m 600V 400V 13A 105C
2038KZ1-BK Saf-D-Grid 400V 10 AWG ST None 1m 600V 400V 30A 105C
2031KK1-BK Saf-D-Grid 400V 14 AWG ST Saf-D-Grid 400V 1m 600V 400V 16A 105C
2035KK1-BK Saf-D-Grid 400V 12 AWG ST Saf-D-Grid 400V 1m 600V 400V 25A 105C
2036KK1-BK Saf-D-Grid 400V 16 AWG ST Saf-D-Grid 400V 1m 600V 400V 13A 105C
2038KK1-BK Saf-D-Grid 400V 10 AWG ST Saf-D-Grid 400V 1m 600V 400V 30A 105C

Metric 400V Cable Configurations

Part Number Connector 1 Cable Connector 2 Cordset Length Voltage Rating Disconnect (AC/DC) Voltage Rating Current Interrupt (AC/DC) Current Rating Maximum Temperature
2041KZ1-BK Saf-D-Grid 400V 1.5mm H05VV-F None 1m 300V 300V 16A 70C
2047KZ1-BK Saf-D-Grid 400V 2.5mm H05VV-F None 1m 300V 300V 25A 70C
2049KZ2-BK Saf-D-Grid 400V 4.0mm H05V2V2-F None 2m 300V 30A (Current Interrupt) 32A (Disconnect) 90C
2041KK1-BK Saf-D-Grid 400V 1.5mm H05VV-F Saf-D-Grid 400V 1m 300V 300V 16A 70C
2047KK1-BK Saf-D-Grid 400V 2.5mm H05VV-F Saf-D-Grid 400V 1m 300V 300V 25A 70C
2049KK2-BK Saf-D-Grid 400V 4.0mm H05V2V2-F Saf-D-Grid 400V 2m 300V 30A (Current Interrupt) 32A (Disconnect) 90C

Universal Cable Configurations

Part Number Connector 1 Cable Connector 2 Cordset Length Voltage Rating Disconnect (AC/DC) Voltage Rating Current Interrupt (AC/DC) Current Rating (UL,CSA / IEC) Temperature Rating
2050KZ1-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F None 1m 300V 300V 16A / 16A 75C UL / 70C IEC
2058KZ1-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F None 1m 300V 300V 20A / 25A 75C UL / 70C IEC
2050KK1-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F Saf-D-Grid 400V 1m 300V 300V 16A / 16A 75C UL / 70C IEC
2058KK1-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F Saf-D-Grid 400V 1m 300V 300V 20A / 25A 75C UL / 70C IEC

Saf-D-Grid 400V to C14 Cable Configurations

Part Number Connector 1 Cable Connector 2 Cordset Length Voltage Rating Disconnect (AC) Voltage Rating Current Interrupt (AC) Current Rating (UL,CSA / IEC) Temperature Rating
2059KN1-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F IEC 320 C14 1m 250V 250V 15A / 10A 70C
2059KN1-RED-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F (RED) IEC 320 C14 (RED) 1m 250V 250V 15A / 10A 70C
2059KN1-BLUE-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F (BLUE) IEC 320 C14 (BLUE) 1m 250V 250V 15A / 10A 70C

Saf-D-Grid 400V to C20 Cable Configurations (14 AWG SJT/1.5MM H05VV-F)

Part Number Connector 1 Cable Connector 2 Cordset Length Voltage Rating Disconnect (AC) Voltage Rating Current Interrupt (AC) Current Rating (UL,CSA / IEC) Temperature Rating
2050KH1-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F IEC 320 C20 1m 250V 250V 16A / 16A 70C
2050KH1-RED-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F (RED) IEC 320 C20 (RED) 1m 250V 250V 16A / 16A 70C
2050KH1-BLUE-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F (BLUE) IEC 320 C20 (BLUE) 1m 250V 250V 16A / 16A 70C

Saf-D-Grid 400V to C20 Cable Configurations (12 AWG SJT/2.5MM H05VV-F)

Part Number Connector 1 Cable Connector 2 Cordset Length Voltage Rating Disconnect (AC) Voltage Rating Current Interrupt (AC) Current Rating (UL,CSA / IEC) Temperature Rating
2058KH1-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F IEC 320 C20 1m 250V 250V 16A / 16A 70C
2058KH2-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F IEC 320 C20 2m 250V 250V 20A / 16A 70C
2058KH1-RED-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F (RED) IEC 320 C20 (RED) 1m 250V 250V 16A / 16A 70C
2058KH2-RED-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F (RED) IEC 320 C20 (RED) 2m 250V 250V 20A / 16A 70C
2058KH1-BLUE-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F (BLUE) IEC 320 C20 (BLUE) 1m 250V 250V 16A / 16A 70C
2058KH2-BLUE-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm H05VV-F (BLUE) IEC 320 C20 (BLUE) 2m 250V 250V 20A / 16A 70C

North American 300V Configurations with Keys for AC Usage

Part Number Connector 1 Cable Connector 2 Cordset Length Voltage Rating Disconnect (AC/DC) Voltage Rating Current Interrupt (AC/DC) Current Rating (UL,CSA / IEC) Temperature Rating
2352-1100-10 Saf-D-Grid 300V KEY A 14 AWG SJT None 1m 300V 300V 16A / 16A 90C
2352-1100-20 Saf-D-Grid 300V KEY A 14 AWG SJT None 2m 300V 300V 16A / 16A 90C
2352-1200-20 Saf-D-Grid 300V KEY B 14 AWG SJT None 2m 300V 300V 16A / 16A 90C
2352-1112-20 Saf-D-Grid 300V KEY A 14 AWG SJT Saf-D-Grid 300V KEY B 2m 300V 300V 16A / 20A 90C
2351-1111-20 Saf-D-Grid 300V KEY A 12 AWG SJT Saf-D-Grid 300V KEY A 2m 300V 300V 20A / 20A 90C
2351-1200-20 Saf-D-Grid 300V KEY B 12 AWG SJT None 2m 300V 300V 20A / 20A 90C
2351-1112-20 Saf-D-Grid 300V KEY A 12 AWG SJT Saf-D-Grid 300V KEY B 2m 300V 300V 20A / 20A 90C
2350-1300-20 Saf-D-Grid 300V KEY C 10 AWG SJT None 2m 300V 300V 30A / 30A 90C

2411220411_Anderson-Power-2002V2-BK_C3095392.pdf

Send RFQ
Stock:
MOQ: