power connector Anderson Power ASMFP30-1X2-RK with compact design and UL1977 IP20 safety certifications
Product Overview
The Anderson Powerpole PP15-45 series offers the smallest Powerpole housings, designed for versatile wire-to-wire or wire-to-board applications. These connectors accommodate wire sizes from #20 AWG (0.75 mm) to #10 (6 mm), providing power capabilities up to 55 amps per pole. Key features include finger-proof housings for enhanced safety against accidental contact with live circuits and the option for first-mate last-break ground connectors. The series boasts high power density within a compact footprint and allows for the use of both wire and PCB contacts within the same housings.
Product Attributes
- Brand: Powerpole
- Certifications: UL1977 section 10.2, IP20 rated (Finger Proof Housings)
- Material: Housing Plastic Resin Polycarbonate, Contact Retention Spring Stainless Steel, Contact Base Copper Alloy
- Flammability Rating: UL94 V-0
Technical Specifications
| Feature | Description | Part Numbers (Examples) | Minimum Quantity |
|---|---|---|---|
| PP15-45 Finger Proof Housings | Improved design with ribs to protect against accidental contact with live circuits. Meets UL1977 section 10.2 and is rated IP20. Will not mate with standard housings. | 1327FP-BK, 1327FP (Red) 1327G5FP-BK, 1327G5FP (Green) 1327G6FP-BK, 1327G6FP (Black) 1327G7FP-BK, 1327G7FP (White) 1327G8FP-BK, 1327G8FP (Blue) 1327G16FP-BK, 1327G16FP (Yellow) | 2,500 / 200 |
| Green housings are keyed to prevent accidental mating with standard or finger proof Powerpole housings. | 1827G1-BK, 1827G1 | 2,500 / 200 | |
| PP15-45 Standard Housings | Original housing design with an open interface, available in various colors. Will not mate with finger proof housings. | 1327-BK, 1327 (Red) 1327G5-BK, 1327G5 (Green) 1327G6-BK, 1327G6 (Black) 1327G7-BK, 1327G7 (White) 1327G8-BK, 1327G8 (Blue) 1327G16-BK, 1327G16 (Yellow) 1327G17-BK, 1327G17 (Orange) 1327G18-BK, 1327G18 (Gray) 1327G21-BK, 1327G21 (Brown) 1327G22-BK, 1327G22 (Pink) 1327G23-BK, 1327G23 (Purple) | 2,500 / 200 |
| Premate Ground Housings | Green housings | 1827G1-BK, 1827G1 | 2,500 / 200 |
| Tin Plated Power Contacts | Cost-effective performance up to 1,500 mating cycles. | Open Barrel Contacts: 269G3-LPBK, 269G3 (#14-10 AWG) 261G2-LPBK, 261G2 (#14-10 AWG) 201G1H-LPBK, 201G1H (#14-10 AWG) 200G1L-LPBK, 200G1L (#14-10 AWG) 269G1-LPBK, 269G1 (#16-12 AWG) 261G1-LPBK, 261G1 (#16-12 AWG) 269G2-LPBK, 269G2 (#20-16 AWG) 262G1-LPBK, 262G1 (#20-16 AWG) 200G2L-LPBK, 200G2L (#20-16 AWG) | 200 / 5,000 |
| K* - For #10 AWG class K stranded wire or smaller. For larger wires use superflex contacts. SF*- Indicates wires with high stranding such as Super Flex. | |||
| Closed Barrel Contacts: 1331-BK, 1331 (#16-12 AWG) 1332-BK, 1332 (#20-16 AWG) | 200 / 5,000 | ||
| Silver Plated Power Contacts | Maximize performance with up to 10,000 mating cycles. Recommended for circuit interrupt or hot plug applications. Only closed barrel contacts are suitable for soldering. | Open Barrel Contacts: 261G3-LPBK, 261G3 (#14-10 AWG) 201G3H (#14-10 AWG) 200G3L-LPBK, 200G3L (#14-10 AWG) 261G4-LPBK, 261G4 (#16-12 AWG) 262G2-LPBK, 262G2 (#20-16 AWG) 200G4L (#20-16 AWG) | 5,000 / 200 |
| Closed Barrel Contacts: 1331-BK, 1331 (#16-12 AWG) 1332-BK, 1332 (#20-16 AWG) | 5,000 / 200 | ||
| 45A Premate Ground Wire Contacts | Tin or silver plated contacts rated for ground or power. Tin contacts rated for up to 1,500 mating cycles. Silver contacts rated up to 10,000 mating cycles. | Open, Tin: 1830G1-LPBK, 1830G1 (#14-10 AWG) Open, Silver: 1830G2-LPBK, 1830G2 (#14-10 AWG) | 200 / 5,000 |
| Reeled contacts can be used with high volume press and applicator tooling. | |||
| 25A Right Angle PCB Contacts (Tin Plated) | Suitable for right angle applications up to 25A per pole. Tin plating enhances solderability. Cannot be mixed with 45A PCB contacts. For mating with wire contacts only. | Top Row: 1377G1-BK, 1377G1 (Low); 1317G1-BK, 1317G1 (High) Bottom Row: 1377G2-BK, 1377G2 (Low); 1317G2-BK, 1317G2 (High) Top Row: 1377G11-BK, 1377G11 (Low); 1317G11-BK, 1317G11 (High) Bottom Row: 1377G12-BK, 1377G12 (Low); 1317G12-BK, 1317G12 (High) | 1,000 / 100 |
| Dimensions: A (inches/mm), B (inches/mm) | |||
| 25A Vertical PCB Contacts (Tin Plated) | Suitable for vertical applications up to 25A per pole, tin plating enhances solderability. For mating with wire contacts only. | 1377G3-BK, 1377G3 (Low); 1317G3-BK, 1317G3 (High) 1377G4-BK, 1377G4 (Low); 1317G4-BK, 1317G4 (High) 1377G13-BK, 1377G13 (Low); 1317G13-BK, 1317G13 (High) | 1,000 / 100 |
| Dimensions: A (inches/mm) | |||
| 45A Right Angle and Vertical PCB Contacts (Tin Plated) | Suitable for right angle or vertical applications up to 45A per pole. Tin plating enhances solderability. Right angle contacts cannot be mixed with 25A PCB contacts. For mating with wire contacts only. | Vertical: 3-5911P1, 1335G1 Right Angle Bottom Row: 3-5912P1, 1336G1 Right Angle Top Row: 3-5913P1, 1337G1 | 1,000 / 100 |
| 45A Premate Ground PCB Contacts | Right angle contacts suitable for power or ground. Use to mate with 45A ground wire contacts. Tin plated contacts rated up to 1,500 mating cycles. Can be used with other 45A PCB connectors in the bottom row. | PCB, Bottom Row Low: 3-5952P1, 1836G1 | 1000 / 100 |
| Ultrasonically Welded Assemblies | Feature housings ultrasonically welded into a one-piece connector unit. Allows Powerpole 15-45 connectors to be used as a durable one-piece connector header. | Single Row 1x2 Assemblies: ASMPP30-1X2-RK, ASMPV45-1X2-RK, ASMPR45-1X2-RK, ASMFP30-1X2-RK, ASMFV45-1X2-RK, ASMFR45-1X2-RK Single Row 1x3 Assemblies: ASMFP30-1X3-KER, ASMFR45-1X3-KER, ASMFP30-1X3-KEW, ASMFV45-1X3-KEW, ASMFR45-1X3-KEW Two Row 2x1 Assemblies: ASMFP30-2X1-KR, ASMFV45-2X1-KR, ASMFR45-2X1-KR, ASMFP30-2X1-RK, ASMFV45-2X1-RK, ASMFR45-2X1-RK Two Row 2x2 Assemblies: ASMFP30-2X2-KRWE, ASMFR45-2X2-WEKR | 500 |
| Type: STD = Standard Housing, FP = Finger Proof Housing, GND = Ground Housing | |||
| Assembly Configurations: Single Row 1x2, 1x3; Two Row 2x1, 2x2 | |||
| Contact customer service for configurations not shown. | |||
| Powerpole Pak Connector Shells | Enclose stacked groupings of PP15-45 sized housings in a durable black shell. Available in inline, panel mount, and blindmate configurations. Plug shells offer optional integral latches and strain relief. | Plug Shell without Latch: 1461G1-BK, 1461G1 (2-4 Poles); 1461G2-BK, 1461G2 (5-6 Poles); 1461G3-BK, 1461G3 (7-8 Poles) Plug Shell with Latch: 1460G1-BK, 1460G1 (2-4 Poles); 1460G2-BK, 1460G2 (5-6 Poles); 1460G3-BK, 1460G3 (7-8 Poles); 1460G4-BK, 1460G4 (9-10 Poles) Plug Shell with Latch & Non-Conductive Strain Relief: 1460G23-BK, 1460G23 (5-6 Poles) | 1,000 / 500 / 25 |
| Max wire O.D. for 2-4 pole plug shells is 0.60 inches [15.2mm]. For all other plug shells is 0.63 inches [16.0 mm]. Max wire O.D. for 1460G23 is 0.80 inches [20.3 mm]. | |||
| Snap-in Receptacle Shell: 1470G1-BK, 1470G1 (2-4 Poles); 1470G2-BK, 1470G2 (5-6 Poles); 1470G3-BK, 1470G3 (7-8 Poles); 1470G4-BK, 1470G4 (9-10 Poles) | 1,000 / 500 / 25 | ||
| Blindmate Pak Connector | Ideal for panel to panel, bulkhead to bulkhead, or rack mount applications compensating for misalignment. Holds up to 8 positions of PP15-45 connectors. Receptacle side can use wire or PCB contacts. Hardware bag includes retaining pins. | 2x4 Blindmate Plug Shell, Hardware & Pins: BMPP10-45P 2x4 Blindmate Receptacle Shell, Hardware & Pins: BMPP10-45R 2x4 Blindmate Plug Shell: BMHSG-P 2x4 Blindmate Receptacle Shell: BMHSG-R Hardware Bag Plug Side: 110G50 Hardware Bag Receptacle Side: 110G51 | 50 / 25 |
| T Pak 2 Way Splitter | Splits electrical current from one incoming circuit into two outgoing circuits. Standard configuration pre-wired for AC 3 phase, 3 wire plus ground. Can be used for AC single phase or DC 2 wire applications. UL recognition up to 20 amps and 600 volts when mating Powerpole Pak plugs are used with #12 AWG wire. | Assembled T Pak: 20-01 Mating Plug Shell with Latch 2x2: 26-01 Mating Plug Shell without Latch 2x2: 27-01 | 80 |
| Accessories: Mounting Wings | Secure dovetailed Powerpole 15-45 series housings. | Red: 1399G9-BK, 1399G9 Blue: 1399G8-BK, 1399G8 | 2,500 / 100 |
| Accessories: Spacers | Separate housings under high power to minimize derating. Recommended for squaring off blocks for connector shells and mounting clamps. | Red, Short w/ Hole: 1399G1-BK, 1399G1 Red, Long: 1399G2-BK, 1399G2 Red, Short: 1399G6-BK, 1399G6 Black, Long: 1399G10-BK, 1399G10 Blue, Short: 1399G13-BK, 1399G13 White, Short w/ Hole: 1399G14-BK, 1399G14 White, Long: 1399G17-BK, 1399G17 | 2,500 / 100 |
| Accessories: Retaining Pins | Keep stacked Powerpole 15-45 series housings from separating. | 1 Block High: H1507P38, 110G16 2 Block High: 111812P5, 110G17 | 1,000 / 100 |
| Accessories: Mounting Clamp | Fasten a block of Powerpole 15-45 series housings to a panel. | 2 or 4 Pole: 1462G1 3 or 6 Pole: 1462G2 4 or 8 Pole: 1462G3 | 100 sets of 2 |
| Accessories: PCB Mounting Staples | Soldered into place to secure Powerpole 15-45 series housings horizontally to the board. Reduce strain on soldering joints. | 114555P1 (1x1 Short) to 114555P10 (2x2 Long) | 100 |
| Accessories: Retention Clip | Prevent Powerpole 15-45 blocks from unintended disconnects. | 1 Block High: 110G68 | 100 |
| Accessories: Block Lok | Secure mated Powerpole 15-45 series housings together for high vibration or shock applications. | 2 Pole, Black: 110G21 4 Pole, Black: 110G12 | 100 |
| Accessories: Splash Boot | Protect a 2x2 block of Powerpole 15-45 series housings. Designed for through panel or inline applications. Not a hermetic seal. | Female, Black: 1441G1 Male, Black: 1442G1 | 25 |
| Tooling: Reeled Contact Crimp Tool | For PP15/45 Flat Wiping Power & Ground contacts. | APP Applicator (Air Feed): TD0101 (115V), TE0101 (230V) ATS Applicator (Air Feed): TE0102 APP Applicator (Mechanical Feed): 1385519-1, 1385520-1, 1385458-1, 1385460-1 | N/A |
| Tooling: Loose Piece Contact Crimp Tool | For PP15/45 Flat Wiping Power & Ground contacts. | Hand Tool Die: 1387G1, 1388G4, 1389G3, 1387G1, 1388G6, 1309G2 or 1309G8, 1309G3 or 1309G8, 1309G4, 1368 Series, 1387G1, 1387G2, 1388G4, 1389G4, 1388G3, 1304G32, 1388G7, 1383, 1384 | N/A |
| Tooling: APP Press | Pneumatic Bench Tool for PP15/45 contacts. | 1725900-2 or [354500-1], 1424266-1 or [354578-1] | N/A |
| Tooling: Insertion/Extraction Tool | For PP15/45 contacts. | 111038G2 | N/A |
| Specifications: Electrical Current Rating | UL 1977 / CSA/TUV | Singlepole Wire to Wire (10 AWG): 55A / 40A Singlepole Ground Wire to Wire or PCB (10 AWG): 45A / 35A 3x3 Block Wire to Wire (10 AWG): 40A / 27A Singlepole 25A PCB to Wire (12 AWG): 25A / - 2x3 Block 25A PCB to Wire (12 AWG): 25A / 22A* Singlepole 45A PCB to Wire (10 AWG): 45A / 40A* 2x3 Block 45A PCB to Wire (10 AWG): 45A / 25A* | N/A |
| Specifications: Voltage Rating | AC/DC UL 1977: 600V | N/A | |
| Specifications: Dielectric Withstanding Voltage | Volts AC: 2,200 | N/A | |
| Specifications: Avg. Mated Contact Resistance | Milliohms | 15A Wire Contact with 5/8 of #16 AWG: 0.875 30A Wire Contact with 5/8 of #12 AWG: 0.600 45A Wire Contact with 5/8 of #10 AWG: 0.525 45A PCB Contact to Contact: 0.500 25A PCB Contact to Contact: 0.600 | N/A |
| Specifications: UL Hot Plug Current Rating | Amperes | 250 cycles at 72V DC: 45A 250 cycles at 120V DC: 30A | N/A |
| Specifications: UL Ground Short Time Current Test | 45A Premate Ground | #10 AWG Wire (4 Seconds): 750 Amps #12 AWG Wire (4 Seconds): 470 Amps | N/A |
| Specifications: Wire Size Range | AWG: 20 to 10 mm: 0.75 to 6.0 | N/A | |
| Specifications: Max. Wire Insulation Diameter | in.: 0.175 mm: 4.450 | N/A | |
| Specifications: Operating Temperature | F: -4 to 221 C: -20 to 105 (Limited by thermal properties of housing) | Powerpole Housings & Powerpole Pak Shells | N/A |
| Specifications: Mating Cycles | No Load by Plating | Silver (Ag): 10,000 (Wire to Wire) Tin (Sn): 1,500 (Wire to Wire) PCB to Wire: 1,500 | N/A |
| Specifications: Avg. Mating / Unmating Force | Lbf. / N | Low Force Wire, High Force PCB, & Ground: 3 Lbf. / 13 N High Force Wire: 5 Lbf. / 22 N Low Force PCB: 2 Lbf. / 9 N | N/A |
| Specifications: Min. Contact / Spring Retention Force | Lbf. / N | 20 Lbf. / 90 N | N/A |
| Specifications: Powerpole Pak Latch Avg. Defeat Force | Lbf. / N | 150 Lbf. / 667 N | N/A |
| Specifications: PCB Mounting Style | Plated Through Hole | PCB Thickness: 0.090 - 0.150 in. (2.3-3.8 mm) | N/A |
| Specifications: Min. Creepage / Clearance Distance PCB | in. / mm | 25A Creepage & Clearance Adjacent Poles: 0.201 in. / 5.1 mm 45A Creepage & Clearance Adjacent Poles: 0.067 in. / 1.7 mm | N/A |
| Specifications: Mechanical Shock | MIL-STD-202 213 Condition A: 50gs | N/A | |
| Specifications: Vibration | High Frequency MIL-STD-202 204 Condition A: 10gs | N/A |