Trusted Anderson Power 2002V1 Connectors Providing Power Connections with Touch Safe Design Features
Anderson Power Saf-D-Grid Connectors
Product Overview
The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for higher voltage DC or hybrid AC/DC systems. Designed to meet International safety requirements, Saf-D-Grid connectors enable greater power density by providing higher voltage and current ratings within the footprint of an IEC 620 C13/C14. They are suitable for applications requiring safe and efficient AC or DC power connections, including renewable and alternative energy systems. Key safety features include First Mate, Last Break Ground Contact, integral latches to prevent accidental unmating, hot plug rating, touch-safe design, and arc containment.
Product Attributes
- Brand: Anderson Power Products
- Product Line: Saf-D-Grid
- Legacy: Builds on SB and Powerpole connector technology
- Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984
- Materials: High Temp Nylon (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief
- Compliance: RoHS compliant
Technical Specifications
| Specification | Saf-D-Grid 400V | Saf-D-Grid 300VAC |
|---|---|---|
| Voltage Rating (AC/DC) | 600V (UL) / 400V (IEC) | 600V (UL) / 400V (IEC) |
| Current Rating (UL 1977) | See Table on Page 5 | See Table on Page 5 |
| Wire Range | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Dielectric Withstanding Voltage | 3300V | 3300V |
| Operating Temperature | -4 to 176F (-20 to 105C) | -4 to 284F (-20 to 105C) |
| Contact Retention | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention | 60 lb (267N) | 60 lb (267N) |
| Durability | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Receptacle Max Wire Size | 10 AWG (4.0 mm) | N/A |
| Creep and Clearance | 7.0 mm min | 7.0 mm min |
| Max PCB Thickness | 0.093" (2.4 mm) (for PCB contacts only) | N/A |
| Mechanical Shock (IEC 60512-4-6C) | 50g | 50g |
| Vibration (IEC 60512-4-6d) | 20g | 20g |
Specific Model Ratings (Excerpt)
| Series | Wire Size | UL 1977 Current Rating (Amps) | Disconnect (600V) | Current Interrupt (300V/400V) | IEC 61984 Current Rating (Amps) |
|---|---|---|---|---|---|
| SDG 400V Flush Mount | 14 AWG | 20 | 20A UL, CSA | 20A UL, CSA | N/A |
| SDG 400V Ultra Short | 14 AWG | 21 | 20A UL, CSA | 20A UL, CSA | 25A IEC |
| SDG 300 Receptacle Key "A" | 14 AWG | 35 | N/A | 20A UL, CSA | N/A |
| SDG 300 Receptacle Key "C" | 10 AWG | 55 | N/A | 32A UL, CSA | N/A |
Cable Configurations (Excerpt)
| Part Number | Connector 1 | Cable | Connector 2 | Length | Voltage Rating Disconnect (AC/DC) | Current Rating (UL,CSA / IEC) |
|---|---|---|---|---|---|---|
| 2035KZ3-BK | Saf-D-Grid 400V | 12 AWG ST | None | 3m | 600V / 400V | 25A / 25A |
| 2047KK2-BK | Saf-D-Grid 400V | 2.5mm H05VV-F | Saf-D-Grid 400V | 2m | 300V / 300V | 25A / 25A |
| 2058KN3-BLUE-BK | Saf-D-Grid 400V | 12 AWG SJT / 2.5mm H05VV-F (BLUE) | IEC 320 C20 (BLUE) | 3m | 250V / 250V | 20A / 16A |
| 2351-1112-60 | Saf-D-Grid 300V KEY A | 12 AWG SJT | Saf-D-Grid 300V KEY B | 6m | 300V / 300V | 20A / 20A |
2411220411_Anderson-Power-2002V1_C3095943.pdf