Compact Anderson Power 2005V4-BK connector designed to meet IEC and UL standards for DC power systems
Product Overview
The Anderson Power Saf-D-Grid connector system builds upon the established contact technology of SB and Powerpole connectors, offering enhanced features for DC power connections in higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid provides a safe and efficient power connection for both AC and DC currents, offering greater power density and voltage/current capacity within the footprint of an IEC 620 C13/C14 connector. It is ideal for applications requiring reliable power in renewable and alternative energy sources, ensuring system uptime.
Product Attributes
- Brand: Anderson Power
- Product Line: Saf-D-Grid
- Legacy Technology: Built on SB and Powerpole contact technology
- Certifications: UL rated for disconnect up to 400V and 30A, Meets UL 950 and IEC 60950
- Material (Housings): High Temp Nylon 30% Glass, UL94 V-0, Halogen Free; Polycarbonate UL94 V-0
- Material (Springs): Stainless Steel
- Material (Contacts): Copper/Silver Plate
- Material (Shield): Copper/Tin Plate
- Material (Cable/Strain Relief): Thermoplastic UL94 V-2
- Keying Configurations: Single keying for 400V series (DC focus, AC rated); Multiple mechanical keys for 300V series (AC focus, DC rated)
- Features: First Mate, Last Break Ground Contact; Integral Latch; Hot Plug Rated; Touch Safe / Shock Protection; Arcing Protection
- RoHS Compliant: Yes
Technical Specifications
| Specification | Saf-D-Grid 400V | Saf-D-Grid 300VAC |
|---|---|---|
| Mechanical | ||
| Contact Retention | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention | 60 lb (267N) | 60 lb (267N) |
| Durability | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Receptacle Max Wire Size | 10 AWG (4.0 mm) | |
| Creep and Clearance (min) | 7.0 mm | 7.0 mm |
| Max PCB Thickness (PCB contacts) | 0.093" (2.4 mm) | N/A |
| Mechanical Shock (IEC 60512-4-6C) | 50g | 50g |
| Vibration (IEC 60512-4-6d) | 20g | 20g |
| Electrical | ||
| Voltage AC Disconnect (UL/CSA) | 600V | |
| Voltage AC Disconnect (IEC) | 400V | |
| Voltage AC Current Interrupt (UL/CSA) | 600V | |
| Voltage AC Current Interrupt (IEC) | 400V | |
| Voltage DC Disconnect/Interrupt (UL/CSA) | 600V | 600V |
| Voltage DC Disconnect/Interrupt (IEC) | 400V | 400V |
| Current Rating (UL 1977) | See Table on Page 5 | See Table on Page 5 |
| Wire Range | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Dielectric Withstanding Voltage | 3300V | 3300V |
| Operating Temperature | -4 to 176F (-20 to 105C) | -4 to 284F (-20 to 105C) |
| Fault Current Withstand (UL 467) | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) | 14 AWG, 300V, 4s |
| Specific Model Ratings (Examples) | ||
| SDG 300 Receptacle Key "C" 10 AWG | N/A | UL 1977: 55A, CNR: 38A, IEC 61984: N/A, Current Interrupt UL/CNR: 32A, IEC: N/A |
| SDG 400V Ultra Short 10 AWG | UL 1977: 30A, CNR: 30A, IEC 61984: N/A, Current Interrupt UL/CNR: 30A, IEC: N/A | N/A |
| SDG 400V Ultra Short 1.5mm H05VV-F | N/A | UL 1977: N/A, CNR: N/A, IEC 61984: 16A, Current Interrupt UL/CNR: N/A, IEC: 16A |
| Cable Configurations (Examples) | ||
| 2038KZ1-BK (10 AWG ST, None) | 600V Disconnect, 400V Interrupt, 30A Current, 105C | N/A |
| 2047KZ1-BK (2.5mm H05VV-F, None) | 300V Disconnect, 300V Interrupt, 25A Current, 70C | N/A |
| 2058KH2-BK (12 AWG SJT/2.5mm H05VV-F to IEC 320 C20) | 250V Disconnect, 250V Interrupt, 20A/16A Current, 70C | N/A |
| 2350-1300-10 (300V KEY C, 10 AWG SJT) | 300V Disconnect, 300V Interrupt, 30A Current, 90C | N/A |
2411220411_Anderson-Power-2005V4-BK_C3095867.pdf