Safe Anderson Power 2005V3-BK connector featuring first mate last break ground contact and integral latch
Anderson Power Saf-D-Grid Connectors
Product Overview
The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for DC power connections in higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide a safe and efficient power connection for both AC and DC currents, enabling greater power density within the footprint of an IEC 620 C13/C14. Key safety features include a first-mate, last-break ground contact, integral latch for preventing accidental unmating, hot-plug rating for current interruption, touch-safe design with shock protection, and arc containment within the housings. These connectors are ideal for applications where reliable power is critical, including renewable and alternative energy systems.
Product Attributes
- Brand: Anderson Power
- Product Line: Saf-D-Grid
- Technology Basis: Builds on SB and Powerpole contact technology
- Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984 (specific models)
- Safety Features: First Mate, Last Break Ground Contact, Integral Latch, Hot Plug Rated, Touch Safe/Shock Protection, Arcing Protection
- Materials: High Temp Nylon 30% Glass (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief
- Compliance: RoHS compliant
Technical Specifications
| Specification | Saf-D-Grid 400V | Saf-D-Grid 300V AC |
|---|---|---|
| Contact Retention | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention | 60 lb (267N) | 60 lb (267N) |
| Durability | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Receptacle Max Wire Size | 10 AWG (4.0 mm) | N/A |
| Creep and Clearance | 7.0 mm min | 7.0 mm min |
| Max PCB Thickness | 0.093" (2.4 mm) | N/A |
| Mechanical Shock (IEC 60512-4-6C) | 50g | 50g |
| Vibration (IEC 60512-4-6d) | 20g | 20g |
| Voltage AC Disconnect (UL) | 600V | N/A |
| Voltage AC Disconnect (IEC) | 400V | N/A |
| Voltage DC Disconnect (UL) | 600V | N/A |
| Voltage DC Disconnect (IEC) | 400V | N/A |
| Voltage AC Current Interrupt (UL) | 600V | N/A |
| Voltage AC Current Interrupt (IEC) | 400V | N/A |
| Voltage DC Current Interrupt (UL) | 600V | N/A |
| Voltage DC Current Interrupt (IEC) | 400V | N/A |
| Wire Range | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Dielectric Withstanding Voltage | 3300V | 3300V |
| Operating Temperature | -4 to 176F (-20 to 105C) | -4 to 284F (-20 to 105C) |
| Fault Current Withstand (UL 467) | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) | 14 AWG, 300V, 4s |
Receptacle Ratings and Approvals (Sample Data)
| Series | Wire Size | UL 1977 | CNR | IEC 61984 | UL 1977 | CNR | IEC 61984 |
|---|---|---|---|---|---|---|---|
| Current Rating (Amps) | Disconnect (600V) | Current Interrupt (300V/400V) | |||||
| SDG 300 Receptacle Key "A" | 14 AWG | 35 | 25 | N/A | 20 | 20 | N/A |
| SDG 400V Flush Mount | 18 AWG | 18 | 12 | N/A | 12 | 12 | N/A |
| SDG 400V Ultra Short | 14 AWG | 21 | 13 | 25 | 20 | 20 | 20 |
Cable Configurations (Sample Data)
| Part Number | Connector 1 | Cable | Connector 2 | Cordset Length | Voltage Rating Disconnect (AC/DC) | Voltage Rating Current Interrupt (AC/DC) | Current Rating | Temperature Rating |
|---|---|---|---|---|---|---|---|---|
| 2031KZ1-BK | Saf-D-Grid 400V | 14 AWG ST | None | 1m | 600V | 400V | 16A | 105C |
| 2035KK2-BK | Saf-D-Grid 400V | 12 AWG ST | Saf-D-Grid 400V | 2m | 600V | 400V | 25A | 105C |
| 2041KZ3-BK | Saf-D-Grid 400V | 1.5mm H05VV-F | None | 3m | 300V | 300V | 16A | 70C |
| 2050KK6-BK | Saf-D-Grid 400V | 14 AWG SJT / 1.5mm H05VV-F | Saf-D-Grid 400V | 6m | 300V | 300V | 16A / 16A | 75C UL / 70C IEC |
| 2059KN2-RED-BK | Saf-D-Grid 400V | 14 AWG SJT / 1.5mm2 H05VV-F (RED) | IEC 320 C14 (RED) | 2m | 250V | 250V | 15A / 10A | 70C |
| 2058KH3-BLUE-BK | Saf-D-Grid 400V | 12 AWG SJT / 2.5mm2 H05VV-F (BLUE) | IEC 320 C20 (BLUE) | 3m | 250V | 250V | 20A / 16A | 70C |
| 2352-1100-10 | Saf-D-Grid 300V KEY A | 14 AWG SJT | None | 1m | 300V | 300V | 16A | 90C |
| 2351-1200-20 | Saf-D-Grid 300V KEY B | 12 AWG SJT | None | 2m | 300V | 300V | 20A | 90C |
2411220411_Anderson-Power-2005V3-BK_C3095613.pdf