Home > Products > Plugs and Receptacles >Power Entry Modules (PEM) > Safe Anderson Power 2005V3-BK connector featuring first mate last break ground contact and integral latch

Safe Anderson Power 2005V3-BK connector featuring first mate last break ground contact and integral latch

Manufacturer:
Anderson Power
Description:
Power Entry Modules (PEM) RoHS
Category:
Plugs and Receptacles/Power Entry Modules (PEM)
Specifications
Mfr. Part #:
2005V3-BK
Model Number:
2005V3-BK
Introduction

Anderson Power Saf-D-Grid Connectors

Product Overview

The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for DC power connections in higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors provide a safe and efficient power connection for both AC and DC currents, enabling greater power density within the footprint of an IEC 620 C13/C14. Key safety features include a first-mate, last-break ground contact, integral latch for preventing accidental unmating, hot-plug rating for current interruption, touch-safe design with shock protection, and arc containment within the housings. These connectors are ideal for applications where reliable power is critical, including renewable and alternative energy systems.

Product Attributes

  • Brand: Anderson Power
  • Product Line: Saf-D-Grid
  • Technology Basis: Builds on SB and Powerpole contact technology
  • Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984 (specific models)
  • Safety Features: First Mate, Last Break Ground Contact, Integral Latch, Hot Plug Rated, Touch Safe/Shock Protection, Arcing Protection
  • Materials: High Temp Nylon 30% Glass (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief
  • Compliance: RoHS compliant

Technical Specifications

Specification Saf-D-Grid 400V Saf-D-Grid 300V AC
Contact Retention 20 lb (89N) 20 lb (89N)
Plug Latch Retention 20 lb (89N) 20 lb (89N)
Panel Latch Retention 60 lb (267N) 60 lb (267N)
Durability 5,000 Cycles (no load) 5,000 Cycles (no load)
Receptacle Max Wire Size 10 AWG (4.0 mm) N/A
Creep and Clearance 7.0 mm min 7.0 mm min
Max PCB Thickness 0.093" (2.4 mm) N/A
Mechanical Shock (IEC 60512-4-6C) 50g 50g
Vibration (IEC 60512-4-6d) 20g 20g
Voltage AC Disconnect (UL) 600V N/A
Voltage AC Disconnect (IEC) 400V N/A
Voltage DC Disconnect (UL) 600V N/A
Voltage DC Disconnect (IEC) 400V N/A
Voltage AC Current Interrupt (UL) 600V N/A
Voltage AC Current Interrupt (IEC) 400V N/A
Voltage DC Current Interrupt (UL) 600V N/A
Voltage DC Current Interrupt (IEC) 400V N/A
Wire Range 10 AWG to 18 AWG (0.75 mm to 5.5 mm) 10 AWG to 18 AWG (0.75 mm to 5.5 mm)
Dielectric Withstanding Voltage 3300V 3300V
Operating Temperature -4 to 176F (-20 to 105C) -4 to 284F (-20 to 105C)
Fault Current Withstand (UL 467) 14 AWG, 300V, 4s (10 AWG, 750V, 4s) 14 AWG, 300V, 4s

Receptacle Ratings and Approvals (Sample Data)

Series Wire Size UL 1977 CNR IEC 61984 UL 1977 CNR IEC 61984
Current Rating (Amps) Disconnect (600V) Current Interrupt (300V/400V)
SDG 300 Receptacle Key "A" 14 AWG 35 25 N/A 20 20 N/A
SDG 400V Flush Mount 18 AWG 18 12 N/A 12 12 N/A
SDG 400V Ultra Short 14 AWG 21 13 25 20 20 20

Cable Configurations (Sample Data)

Part Number Connector 1 Cable Connector 2 Cordset Length Voltage Rating Disconnect (AC/DC) Voltage Rating Current Interrupt (AC/DC) Current Rating Temperature Rating
2031KZ1-BK Saf-D-Grid 400V 14 AWG ST None 1m 600V 400V 16A 105C
2035KK2-BK Saf-D-Grid 400V 12 AWG ST Saf-D-Grid 400V 2m 600V 400V 25A 105C
2041KZ3-BK Saf-D-Grid 400V 1.5mm H05VV-F None 3m 300V 300V 16A 70C
2050KK6-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm H05VV-F Saf-D-Grid 400V 6m 300V 300V 16A / 16A 75C UL / 70C IEC
2059KN2-RED-BK Saf-D-Grid 400V 14 AWG SJT / 1.5mm2 H05VV-F (RED) IEC 320 C14 (RED) 2m 250V 250V 15A / 10A 70C
2058KH3-BLUE-BK Saf-D-Grid 400V 12 AWG SJT / 2.5mm2 H05VV-F (BLUE) IEC 320 C20 (BLUE) 3m 250V 250V 20A / 16A 70C
2352-1100-10 Saf-D-Grid 300V KEY A 14 AWG SJT None 1m 300V 300V 16A 90C
2351-1200-20 Saf-D-Grid 300V KEY B 12 AWG SJT None 2m 300V 300V 20A 90C

2411220411_Anderson-Power-2005V3-BK_C3095613.pdf

Send RFQ
Stock:
MOQ: