Compact Anderson Power 2002V4-BK connector offering hot plug rating and arcing protection technology
Anderson Power Saf-D-Grid Connectors
Product Overview
The Anderson Power Saf-D-Grid connector system builds upon proven contact technology to provide robust DC power connection solutions for higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors offer enhanced power density in the footprint of an IEC 620 C13/C14, enabling up to 40A and 600V DC or AC where standard IEC connectors are limited. Key safety features include first-mate, last-break ground contact, integral latches to prevent accidental unmating, hot-plug rating for various loads, touch-safe/shock protection, and arcing protection. Ideal for renewable and alternative energy sources, Saf-D-Grid ensures safe and efficient power connections in demanding applications.
Product Attributes
- Brand: Anderson Power
- Product Line: Saf-D-Grid
- Legacy: Builds on SB and Powerpole connector technology
- Certifications: UL 950, IEC 60950, UL 1977, CSA 22.2, UL 817, IEC 61984 (specific models)
- Materials: High Temp Nylon 30% Glass (UL94 V-0, Halogen Free), Polycarbonate (UL94 V-0), Stainless Steel Springs, Copper/Silver Plate Contacts, Copper/Tin Plate Shield, Thermoplastic Cable/Strain Relief
- Keying: Single keying configuration for 400V series (DC/AC); Multiple mechanical keys for 300V series (AC/DC)
- Safety Features: First Mate/Last Break Ground, Integral Latch, Hot Plug Rated, Touch Safe/Shock Protection, Arcing Protection
Technical Specifications
| Specification | Saf-D-Grid 400V | Saf-D-Grid 300V |
|---|---|---|
| Voltage Rating (AC Disconnect) | 600V (UL 1977/CSA 22.2) / 400V (IEC) | 600V (UL 1977/CSA 22.2) / 400V (IEC) |
| Voltage Rating (DC Disconnect) | 600V (UL 1977/CSA 22.2) / 400V (IEC) | 600V (UL 1977/CSA 22.2) / 400V (IEC) |
| Voltage Rating (AC Current Interrupt) | 600V (UL 1977/CSA 22.2) / 400V (IEC) | 600V (UL 1977/CSA 22.2) / 400V (IEC) |
| Voltage Rating (DC Current Interrupt) | 600V (UL 1977/CSA 22.2) / 400V (IEC) | 600V (UL 1977/CSA 22.2) / 400V (IEC) |
| Current Rating (UL 1977) | See Table on Page 5 | See Table on Page 5 |
| Wire Range | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Dielectric Withstanding Voltage | 3300V | 3300V |
| Operating Temperature | -20 to 105C (-4 to 176F) | -20 to 105C (-4 to 284F) |
| Contact Retention | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention | 60 lb (267N) | 60 lb (267N) |
| Durability | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Receptacle Max Wire Size | 10 AWG (4.0 mm) | N/A |
| Creep and Clearance | 7.0 mm min | 7.0 mm min |
| Max PCB Thickness (for PCB contacts only) | 0.093" (2.4 mm) | N/A |
| Mechanical Shock (IEC 60512-4-6C) | 50g | 50g |
| Vibration (IEC 60512-4-6d) | 20g | 20g |
| Fault Current Withstand (UL 467) | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) |
Specific Model Ratings (Examples)
| Series | Wire Size | UL 1977 Rating (Amps) | IEC 61984 Rating (Amps) | Disconnect (AC/DC) | Current Interrupt (AC/DC) |
|---|---|---|---|---|---|
| SDG 300 Receptacle Key "A" | 14 AWG | 35 | N/A | 25 | 20 |
| SDG 400V Flush Mount | 14 AWG | 20 | N/A | 20 | 20 |
| SDG 400V Ultra Short | 14 AWG | 21 | 25 | 20 | 20 |
| SDG 400V Ultra Short | 10 AWG | 30 | N/A | 30 | 30 |
Cable Configurations (Examples)
| Part Number | Connector 1 | Cable | Connector 2 | Length | Voltage Rating Disconnect (AC/DC) | Current Rating (UL,CSA / IEC) |
|---|---|---|---|---|---|---|
| 2031KZ1-BK | Saf-D-Grid 400V | 14 AWG ST | None | 1m | 600V | 16A / N/A |
| 2035KK2-BK | Saf-D-Grid 400V | 12 AWG ST | Saf-D-Grid 400V | 2m | 600V | 25A / N/A |
| 2041KZ1-BK | Saf-D-Grid 400V | 1.5mm H05VV-F | None | 1m | 300V | 16A / 16A |
| 2047KK3-BK | Saf-D-Grid 400V | 2.5mm H05VV-F | Saf-D-Grid 400V | 3m | 300V | 25A / 25A |
| 2050KZ1-BK | Saf-D-Grid 400V | 14 AWG SJT / 1.5mm H05VV-F | None | 1m | 300V | 16A / 16A |
| 2058KK2-BK | Saf-D-Grid 400V | 12 AWG SJT / 2.5mm H05VV-F | Saf-D-Grid 400V | 2m | 300V | 20A / 25A |
| 2059KN1-BK | Saf-D-Grid 400V | 14 AWG SJT / 1.5mm2 H05VV-F | IEC 320 C14 | 1m | 250V | 15A / 10A |
| 2050KH2-BK | Saf-D-Grid 400V | 14 AWG SJT / 1.5mm2 H05VV-F | IEC 320 C20 | 2m | 250V | 16A / 16A |
| 2058KH3-BLUE-BK | Saf-D-Grid 400V | 12 AWG SJT / 2.5mm2 H05VV-F (BLUE) | IEC 320 C20 (BLUE) | 3m | 250V | 20A / 16A |
| 2352-1100-20 | Saf-D-Grid 300V KEY A | 14 AWG SJT | None | 2m | 300V | 16A / N/A |
| 2351-1112-30 | Saf-D-Grid 300V KEY A | 12 AWG SJT | Saf-D-Grid 300V KEY B | 3m | 300V | 20A / N/A |
| 2350-1300-60 | Saf-D-Grid 300V KEY C | 10 AWG SJT | None | 6m | 300V | 30A / N/A |
2411220411_Anderson-Power-2002V4-BK_C3094981.pdf