Robust Anderson Power 160-13 Battery Connector with Zinc Chromate Plated Hardware and Polymer Housing
Product Overview
The Anderson A Series Battery Connectors are engineered for user-friendly assembly and robust performance in demanding industrial environments. Featuring an innovative contact carrier, these connectors simplify the assembly process. They are constructed with advanced polymer housings for superior resistance to impact, acid, and temperature extremes, and utilize silver-plated copper contacts for excellent conductivity and durability. The A Series connectors are RoHS compliant and designed for years of reliability. They are ideal for a wide range of industrial applications including Material Handling, Battery Charging, Utility Vehicles, Motive Power, and Sweepers/Scrubbers.
Product Attributes
- Brand: Anderson
- Series: A Series
- Materials: Advanced Polymer Housings (PA6 glass filled), Silver Plated Copper Contacts, Steel (zinc chromate plate hardware)
- Compliance: RoHS compliant
- Safety Agency Approvals: UL and CSA
- Voltage Keying Options: Dry-Cell, Wet-Cell, Universal
Technical Specifications
| Specification | A80 | A160 | A320 |
|---|---|---|---|
| Avg. Mating Force (N/lb) | 68 (15.3) | 170 (38.2) | 71 (16.0) |
| Contact Retention (min N/lb) | 134 (30) | 445 (100) | 445 (100) |
| Degree of Protection | IP23 | IP23 | IP23 |
| Flammability | UL94 HB, Horizontal Burn | UL94 HB, Horizontal Burn | UL94 HB, Horizontal Burn |
| Voltage Ratings (AC/DC) | 600V (CSA/UL) | 600V (CSA/UL) | 600V (CSA/UL) |
| DWV (AC) | 2200 | 2200 | 2200 |
| Operating Temperature (C) | -25 to 75C | ||
| Avg. Contact Resistance - Power (micro-ohms) | 65 | 55 | 30 |
| Avg. Contact Resistance - Aux. (micro-ohms) | 1100 | 920 | 1000 |
| Wire Range - Power Min. (mm/AWG) | 10 mm (#8) | 16 mm (#6) | 50 mm (1/0) |
| Wire Range - Power Max. (mm/AWG) | 35 mm (#2) | 50 mm (1/0) | 120 mm (4/0) |
| Wire Range - Upper Aux. Min. (mm/AWG) | 1.5 mm (#18) | 4 mm (#12) | 4 mm (#12) |
| Wire Range - Upper Aux. Max. (mm/AWG) | 2.5 mm (#14) | 4 mm (#12) | 4 mm (#12) |
| Wire Range - Lower Pilot Aux. Min. (mm/AWG) | 1.5 mm (#18) | 6 mm (#10) | 6 mm (#10) |
| Wire Range - Lower Pilot Aux. Max. (mm/AWG) | 2.5 mm (#14) | 6 mm (#10) | 6 mm (#10) |
| Current Ratings (Amperes) - CSA* | 70-120A (10-35 mm) | 90-180A (16-35 mm) | 165-425A (50-120 mm) |
| Current Ratings (Amperes) - UL** | 90-160A (16-35 mm) | 120-220A (16-50 mm) | 220-425A (50-120 mm) |
| Housing Dimensions (mm/in) - Male A | 68.0 / 2.68 | 83.5 / 3.29 | 89.5 / 3.52 |
| Housing Dimensions (mm/in) - Male B | 74.4 / 2.93 | 103.8 / 4.09 | 123.5 / 4.86 |
| Housing Dimensions (mm/in) - Male C | 26.1 / 1.03 | 33.4 / 1.31 | 40.8 / 1.61 |
| Housing Dimensions (mm/in) - Female A | 68.0 / 2.68 | 83.5 / 3.29 | 89.5 / 3.52 |
| Housing Dimensions (mm/in) - Female B | 73.8 / 2.91 | 104.0 / 4.09 | 117.0 / 4.61 |
| Housing Dimensions (mm/in) - Female C | 26.1 / 1.03 | 32.6 / 1.28 | 37.6 / 1.48 |
2411041644_Anderson-Power-160-13_C5873000.pdf