mains power connector Bulgin PX0695/10/63 IEC 60320 C14 inlet with flange fixing and screw terminals
IEC Connectors
A comprehensive range of quality mains-rated inlets, outlets, and connectors conforming to IEC and EN 60320 specifications. These connectors carry UL, CSA, VDE, and other approvals, offering solutions for most mains-powered equipment and cable applications with electrical ratings up to 20A, 250V (UL). Available in various mounting styles and terminations, including flange fixing, snap-to-panel, and PCB mounting, with options for solder tabs, fast-on tabs, screw terminals, and PC spills. The range is complemented by insulating boots, retaining clips, and safety covers. Most styles are available in standard black, white, or grey, with special colors to match OEM equipment also supplied (subject to product approval requirements).
Product Attributes
- Conforms to IEC and EN 60320 specifications
- Approvals: UL, CSA, VDE, ENEC
- Available Colors: Black, White, Grey, Special OEM colors
- Mouldings: Nylon, Flammability Rating UL94V-0
- Contacts: Brass, Clean (various plating options mentioned)
- RoHS Compliant
Technical Specifications
IEC 60320-1 Sheet No: C14
| Model | Mounting | Termination | Current Rating | Notes |
|---|---|---|---|---|
| PX0579 | Flange Fixing | Tabs/Screw Terminals | 10A, 250V AC | |
| PX0580 | Flange Fixing | Tabs/Screw Terminals | 10A, 250V AC | |
| PX0580/PC | PC Flange Rear Mount | PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | Supplied Rear Cover |
| PX0580/PC/7 | PC Flange Rear Mount | PC Spills, 4.8mm Top Tab (earth) | 10A, 250V AC (15A, 250V AC UL & CSA) | Supplied Rear Cover |
| PX0575 | Snap fit to Panel | Tabs/Screw Terminals | 10A, 250V AC (15A, 250V AC UL & CSA) | Fits Panel Thickness 1, 1.5, 2.0 or 3.0mm |
| PX0575/10/28 | Snap fit to Panel | 2.8mm Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | Fits Panel Thickness 1mm |
| PX0575/10/PC | Snap fit to Panel | PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | Fits Panel Thickness 1mm |
| PF0001 | Flanged Mount Fused Inlet | Tabs | 10A, 250V AC | Single Fuse 5 x 20mm, Spare Fuse Facility |
| PF0001/PC | PC Flanged Mount Fused Inlet | PC Spills - Horizontal | 10A, 250V AC | Single Fuse 5 x 20mm, Spare Fuse Facility |
| PF0002 | Flanged Mount Fused Inlet | Tabs | 10A, 250V AC | Single Fuse 5 x 20mm, Spare Fuse Facility, Fuse Contacts Isolated |
| PF0011 | Snap Fit to Panel Fused Inlet | Tabs | 10A, 250V AC | Single Fuse 5 x 20mm, Spare Fuse Facility |
| PF0011/PC | Snap Fit to Panel Fused Inlet | PC Spills | 10A, 250V AC | Single Fuse 5 x 20mm, Spare Fuse Facility |
| PF0030 | Flanged Mount Fused Inlet | Tabs | 10A, 250V AC | Twin Fused 5 x 20mm |
| PF0030/PC | PC Flanged Mount Fused Inlet | PC Spills | 10A, 250V AC | Twin Fused 5 x 20mm |
| PF0033 | Snap Fit to Panel Fused Inlet | Tabs | 10A, 250V AC | Twin Fused 5 x 20mm |
| PX0587 | Cable Mounting | Screw Terminals | 10A, 250V AC | Class I, Straight Female Connector |
| PX0587/SE | Cable Mounting | Screw Terminals | 10A, 250V AC | Class I, Side Entry Female Connector |
| PX0588 | Cable Mounting | Screw Terminals | 10A, 250V AC | Class I, Right Angle Female Connector |
| PX0597 | Cable Mounting | Screw Terminals | 10A, 250V AC | Class I, Hot Condition, Straight Female Connector |
| PX0590 | Flange Mount | Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | Class I, Hot Condition |
| PX0595 | Snap Fit to Panel | Tabs/Screw Terminals | 10A, 250V AC (15A, 250V AC UL & CSA) | Class I, Hot Condition, Fits Panel Thickness 1, 1.5, 2.0 or 3.0mm |
| PX0690 | Flanged Mount | Tabs/Screw Terminals | 10A, 250V AC (15A, 250V AC UL & CSA) | Class II, Cold Condition, Two Plug (No Earth Plug) |
| PX0691 | Snap Fit to Panel | Tabs/Screw Terminals | 10A, 250V AC (15A, 250V AC UL & CSA) | Class II, Cold Condition, Two Plug (No Earth Plug), Fits Panel Thickness 1, 1.5, 2.0 or 3.0mm |
| PX0691/PC | Snap Fit to Panel | PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | Class II, Cold Condition, Two Plug (No Earth Plug), Fits Panel Thickness 1, 1.5, 2.0 or 3.0mm |
| PF0006 | Flanged Mount Fused Inlet | Tabs | 10A, 250V AC | Single Fuse 5 x 20mm, Two Plug Class II (No Earth Plug) |
| PF0007 | Flanged Mount Fused Inlet | Tabs | 10A, 250V AC | Single Fuse 5 x 20mm (Fuse Contacts Isolated), Two Plug Class II (No Earth Plug) |
| PF0016 | Snap Fit to Panel Fused Inlet | Tabs | 10A, 250V AC | Single Fuse 5 x 20mm, Two Plug Class II (No Earth Plug) |
| PX0599 | Cable Connector | Screw Terminals | 16A, 250V AC | Class I, Cold Condition, C19 Straight Female |
| PX0596 | Flange Mount Inlet | Tabs | 16A, 250V AC (20A, 250V AC UL and cUL) | Class I, Cold Condition, C20 |
| PX0598 | Snap Fit to Panel Inlet | Tabs | 16A, 250V AC (20A, 250V AC UL and cUL) | Class I, Cold Condition, C20, Fits Panel Thickness 1, 1.5, 2.0 or 3.0mm |
| PX0686 | Cable Mounting | Screw Terminals | 10A, 250V AC | Class I, Rewirable, Male Connector |
| PX0686/SE | Cable Mounting | Screw Terminals | 10A, 250V AC | Class I, Rewirable, Side Entry Male Connector |
| PX0685 | Cable Mounting | Screw Terminals | 10A, 250V AC | Class I, Rewirable, Right Angle Male Connector |
| PX0716 | Snap Fit to Panel | Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | Class I, Inlet/Outlet combination, Fits Panel Thickness 1.2mm |
| PX0675 | Flange Mount Outlet | Tabs/PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | Class I, Rewirable |
| PX0675/PC | PC Flange Rear Mount Outlet | PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | Class I, Rewirable |
| PX0695 | Snap Fit to Panel Outlet | Tabs/PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | Class I, Rewirable |
| PX0783 | Snap Fit to Panel Outlet | Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | Class I, Shuttered |
| PX0793 | Flange Mount Outlet | Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | Class I, Shuttered |
| PX0793/1 | Flange Mount Outlet | Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | Class I, Shuttered, Rectangular Flange Mount |
| PX0705 | Flange Mount Outlet | Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | Class II, Two Plug (No Earth Plug) |
| PX0725 | Snap Fit to Panel Outlet | Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | Class II, Two Plug (No Earth Plug) |
Accessories
| Accessory | Part Number | Description | Compatibility |
|---|---|---|---|
| Retaining Clip | KT0006 | Prevents accidental removal of connector. | Fits flanged inlets (e.g., PX0580, PX0590, PX0690, PX0675, PX0793). |
| Retaining Clip | KT0009 | Prevents accidental removal of connector. | Fits fused flanged inlets (e.g., PF0001, PF0030). |
| Retaining Clip | KT0012 | Prevents accidental removal of connector. | For use with PX0596 flanged inlet and PX0599 connector. |
| Blanking Cover | PNo 14228 | Protects front of outlet connector, protects against accidental electric shock. | For PX0578, PX0675, PX0695, PX0783, PX0793, PX0716. |
| Insulation Boot | PNo 14340 | Protects rear of connector, protects against accidental electric shock. | For PS20, PS21, PS25, PS26. |
| Insulation Boot | PNo 14317 | Protects rear of connector, protects against accidental electric shock. | For PF0030, PF0033 (except /PC versions). |
| Insulation Boot | PNo 11328 | Protects rear of connector, protects against accidental electric shock. | For PX0575, PX0579, PX0580, PX0590, PX0595. |
| Insulation Boot | PNo 11987 | Protects rear of connector, protects against accidental electric shock. | For PF range (PF0001, PF0002, PF0006, PF0007, PF0011, PF0016) (Except /PC versions). |
| Insulation Boot | PNo 12075 | Protects rear of connector, protects against accidental electric shock. | For PX0675, PX0695, PX0705, PX0725, PX0783, PX0793, PX0793/1 (Except /PC versions). |
| Insulation Boot | PNo 14064 | Protects rear of connector, protects against accidental electric shock. | For PX0596, PX0598. |
2411220415_Bulgin-PX0695-10-63_C17666605.pdf
| Image | Part # | Description | |
|---|---|---|---|
|
|
Compact Panel Power Entry Modules Bulgin BZM42Z000053C IEC Connector with Single Contact Switch |
Power Entry Modules (PEM) RoHS
|