Home > Products > Headers, Male Pins >Headers, Male Pins > Quick mating connector system EATON SMS36GE4 for machinery railway and robotics applications

Quick mating connector system EATON SMS36GE4 for machinery railway and robotics applications

Manufacturer:
EATON
Description:
Headers, Male Pins RoHS
Category:
Headers, Male Pins/Headers, Male Pins
Specifications
Mfr. Part #:
SMS36GE4
Model Number:
SMS36GE4
Introduction

SMS Series Quick Mating Connectors

The SMS Series offers a versatile and cost-effective quick mating connector system for rapid assembly and installation. Designed for high-density applications in tight spaces, these connectors feature a push-to-mate and press-to-unmate mechanism for easy operation. They provide reliable connections with features like pin protection skirts, positive polarization keys, and retention locks. Integrated strain relief hoods are available for cable management, and the connectors accept TRIM TRIO size 16 contacts. Typical applications include machinery, railway, and robotics.

Product Attributes

  • Brand: SOURIAU
  • Registered Trademark: SOURIAU
  • Origin: 2018 SOURIAU
  • Material: Polyamide 6.6
  • Flammability Rating: UL94 V2 (Black), UL94 V0 & HL3/R22 - HL3/R23 following EN 45545-2 (White)
  • Certifications: UL recognized File Nr.: E238675, CSA certified File Nr.: LR44961-21

Technical Specifications

Part NumberNbr. of ContactsBody VariationFlammabilityWire Insulation Acceptance (max. mm)Operating Temperature (C)Insulation Resistance (M min.)Test Potential (VAC)DurabilitySealing PerformanceElectrical Performance (UL/CSA)
SMS2R1/SMS2R32Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS3R1/SMS3R33Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS4R1/SMS4R34Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS6R1/SMS6R36Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS9R1/SMS9R39Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS12R1/SMS12R312Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS15R1/SMS15R315Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS18R1/SMS18R318Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS24R1/SMS24R324Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS36R1/SMS36R336Panel mount receptacleUL94 V2 / UL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS2P12Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS3P13Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS4P14Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS6P16Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS9P19Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS12P112Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS15P115Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS18P118Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS24P124Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS36P136Cable plug without strain relief hoodUL94 V24.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS2PD32Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS3PD33Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS4PD34Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS6PD36Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS9PD39Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS12PD312Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS15PD315Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS18PD318Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS24PD324Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS36PD336Cable plug without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS2RD32Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS3RD33Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS4RD34Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS6RD36Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS9RD39Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS12RD312Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS15RD315Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS18RD318Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS24RD324Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS36RD336Cable receptacle without strain relief hoodUL94 V04.19-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS2RDH1/SMS2RDH32Cable receptacle with integrated strain relief hoodUL94 V2 / UL94 V00.5-8.4-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS3RDH1/SMS3RDH33Cable receptacle with integrated strain relief hoodUL94 V2 / UL94 V00.8-7.3-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS4RDH1/SMS4RDH34Cable receptacle with integrated strain relief hoodUL94 V2 / UL94 V01.5-10-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS6RDH1/SMS6RDH36Cable receptacle with integrated strain relief hoodUL94 V2 / UL94 V01.7-9.2-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS9RDH1/SMS9RDH39Cable receptacle with integrated strain relief hoodUL94 V2 / UL94 V03.9-14.2-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS12RDH1/SMS12RDH312Cable receptacle with integrated strain relief hoodUL94 V2 / UL94 V04.0-15.0-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS15RDH1/SMS15RDH315Cable receptacle with integrated strain relief hoodUL94 V2 / UL94 V05.0-16.2-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS18RDH1/SMS18RDH318Cable receptacle with integrated strain relief hoodUL94 V2 / UL94 V0N/A-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS2PDH1/SMS2PDH32Cable plug with integrated strain relief hoodUL94 V2 / UL94 V00.5-8.4-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS3PDH1/SMS3PDH33Cable plug with integrated strain relief hoodUL94 V2 / UL94 V00.8-7.3-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS4PDH1/SMS4PDH34Cable plug with integrated strain relief hoodUL94 V2 / UL94 V01.5-10-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS6PDH1/SMS6PDH36Cable plug with integrated strain relief hoodUL94 V2 / UL94 V01.7-9.2-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS9PDH1/SMS9PDH39Cable plug with integrated strain relief hoodUL94 V2 / UL94 V03.9-14.2-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS12PDH1/SMS12PDH312Cable plug with integrated strain relief hoodUL94 V2 / UL94 V04.0-15.0-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS15PDH1/SMS15PDH315Cable plug with integrated strain relief hoodUL94 V2 / UL94 V05.0-16.2-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A
SMS18PDH1/SMS18PDH318Cable plug with integrated strain relief hoodUL94 V2 / UL94 V0N/A-55 to +10550002000500 matingsIP40250V - 10A / 250V - 15A

2411061534_EATON-SMS36GE4_C22108718.pdf

Related Products
Send RFQ
Stock:
MOQ: