power branching component WEIDMULLER 1126840000 with IP20 protection and UL 94 V0 flammability rating
Product Overview
The PT6 DC is a power distribution solution designed for efficient power supply and branching. It utilizes uncut cables with cross-sections ranging from 1.5 to 6 mm for power distribution. Power supply and T-branching are facilitated through PUSH IN connections (0.5 to 10 mm) and/or plug-in connections (0.5 to 4 mm). Clear assignment of wires is ensured by colored markings, making it suitable for power supply, power distribution, and power branching applications.
Product Attributes
- Brand: Weidmller
- Model: PT6 DC
- Origin: Germany
- Insulating Material: PA
- Flammability Rating: UL 94 V-0
- Can be coded: Yes
- Silicone: No
- Protection Degree: IP20
- Certifications: ROHS Conform, cURus (File Number E60693)
Technical Specifications
| Specification | Value |
|---|---|
| Dimensions | |
| Depth | 54 mm (2.126 inch) |
| Height | 139.5 mm (5.492 inch) |
| Width | 61.5 mm (2.421 inch) |
| Net weight | 191.15 g |
| Temperatures | |
| Storage temperature | -40 C...85 C |
| Operating temperature | -40 C...55 C |
| Clamping capacity, IDC connection | |
| Blade size | 0.6 x 3.5 mm |
| Connection cross-section, finely stranded, min. | 2.5 mm |
| Connection cross-section, finely stranded, max. | 6 mm |
| Connection cross-section, stranded, min. | 2.5 mm |
| Connection cross-section, stranded, max. | 6 mm |
| Wire cross-section, solid, min. | 1.5 mm |
| Wire cross-section, solid, max. | 6 mm |
| Clamping capacity, PUSH IN connection | |
| Blade size | 0.6 x 3.5 mm |
| Stripping length | 14 mm |
| Cross-section for connected wire, solid, min. | 0.5 mm |
| Cross-section for connected wire, solid, max. | 6 mm |
| Cross-section for connected wire, flexible, min. | 0.5 mm |
| Cross-section for connected wire, flexible, max. | 10 mm |
| Cross-section for connected wire, flexible with wire-end ferrules (12mm, DIN 46228/1), min. | 0.5 mm |
| Cross-section for connected wire, flexible with wire-end ferrules (12mm, DIN 46228/1), max. | 6 mm |
| Cross-section for connected wire, flexible with wire-end ferrules (12mm, DIN 46228/4), min. | 0.5 mm |
| Cross-section for connected wire, flexible with wire-end ferrules (12mm, DIN 46228/4), max. | 6 mm |
| Cross-section for connected wire, flexible with wire-end ferrules (8mm, DIN 46228/1), min. | 0.5 mm |
| Cross-section for connected wire, flexible with wire-end ferrules (8mm, DIN 46228/1), max. | 6 mm |
| Cross-section for connected wire, flexible with wire-end ferrules (8mm, DIN 46228/4), min. | 0.5 mm |
| Cross-section for connected wire, flexible with wire-end ferrules (8mm, DIN 46228/4), max. | 6 mm |
| Wire connection cross section, stranded, PUSH IN connection, min. | 0.5 mm |
| Wire connection cross section, stranded, PUSH IN connection, max. | 6 mm |
| Finely-stranded flexible, min. PUSH IN connection | 0.5 mm |
| Finely-stranded flexible, max. PUSH IN connection | 6 mm |
| Rated data acc. to IEC | |
| Rated cross-section | 6 mm |
| Rated current | 41 A |
| Rated impulse withstand voltage | 8 kV |
| Rated voltage | 800 V |
| Standards | IEC |
| Rated data acc. to UL | |
| Note | For use with UL-listed TC- ER cables |
| Rated current (Use group D / UL 1059) | 30 A |
| Rated voltage (Use group D / UL 1059) | 600 V |
| Standards | UL 1059 |
| Wire connection cross section AWG, min. | AWG 10 |
| Wire connection cross section AWG, max. | AWG 14 |
| Classifications | |
| ETIM 6.0 | EC002498 |
| ETIM 7.0 | EC002498 |
| ETIM 8.0 | EC002498 |
| ECLASS 9.0 | 27-14-25-90 |
| ECLASS 9.1 | 27-14-25-90 |
| ECLASS 10.0 | 27-14-25-90 |
| ECLASS 11.0 | 27-14-25-90 |
| ECLASS 12.0 | 27-14-25-90 |
2412231652_WEIDMULLER-1126840000_C22045067.pdf