electrical connector CONNFLY Elec DS1011-16SBSiB7-B with 10 contacts gray housing and standard latch mounting
Specifications
Row Spacing:
2.54mm
Operating Temperature:
-40℃~+105℃
Color:
黑色
Contact Plating:
金
Number Of Positions Or Pins:
2x8P
Number Of PINs Per Row:
8
Number Of Rows:
2
Pitch:
2.54mm
Connector Type:
牛角扣
Mounting Type:
直插
Mfr. Part #:
DS1011-16SBSiB7-B
Package:
Through Hole,P=2.54mm
Model Number:
DS1011-16SBSiB7-B
Introduction
Product Overview
This product offers reliable electrical and environmental characteristics suitable for various applications. It features specific contact resistance, insulation resistance, and dielectric withstanding voltage, with an operating temperature range of -40C to +105C. Available in different configurations and plating levels, it is designed for PCB mounting.
Product Attributes
- Brand: CONNFLY ELECTRONIC CO. LTD ()
- Origin: Not specified
- Material: Not specified
- Color: Gray (Housing color)
- Certifications: Not specified
Technical Specifications
| No.of contacts | Mounting type | Housing type | Housing color | Contact plating | Lock | DIM. (mm) | Electrical characteristics | Environment characteristics |
| 10 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Standard latch | Straight type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Special latch | Straight type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Standard latch | R/A type | Gray | Level B | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Special latch | R/A type | Gray | Level B | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Big latch housing | Straight type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Big latch housing | R/A type | Black | Level B | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Big latch housing | Straight type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Big latch housing | R/A type | Black | Level 3A | Big latch housing | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Standard latch | Straight type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Standard latch | R/A type | Gray | Si: Full Gold flash | Standard latch | 7.90 (standard) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Special latch | Straight type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 10 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 14 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 16 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 20 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 24 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 26 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 30 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 34 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 40 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 50 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 60 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
| 64 | Special latch | R/A type | Gray | Si: Full Gold flash | Special latch | 4.50 (special) | Contact resistance: 20m Max. INITIAL. Dielectric withstanding voltage: 500V AC(rms) for 1 minute. Insulation resistance: 1000M Min. | Temperature: -40C~+105C. |
2501090933_CONNFLY-Elec-DS1011-16SBSiB7-B_C7431123.pdf
Related Products
Gray housing electrical connector CONNFLY Elec DS1011-60SBSiA7-B with big latch and level B plating
Connector IDC Header Through Hole 60 position 2.54mm
electrical connector CONNFLY Elec DS1015-10MN2A with copper alloy contacts and thermoplastic insulation
Connector 10 position 2.54mm
Thermoplastic Insulated Connector with Copper Alloy Contacts and High Electrical Performance CONNFLY Elec DS1017-10MA2B
Connector 10 position 2mm
connector CONNFLY Elec DS1017-20MA2B with copper alloy contacts and thermoplastic UL 94V-0 insulator material
Connector 20 position 2mm
Electrical connector CONNFLY Elec DS1011-34SBSiA7-B with 10 contacts gray housing and full gold flash plating
Connector IDC Header Through Hole 34 position 2.54mm
Industrial Grade Connector CONNFLY Elec DS1013-30RSiB-B-0 with R A V T SMT Elevator Mounting Options
Connector IDC Header Through Hole, Right Angle 30 position 2.54mm
connection solution CONNFLY Elec DS1014-14SF1B-B with multiple housing colors and plating levels
Connector Through Hole 14 position 2mm
CONNFLY Elec DS1015-01-08R6 electronic connector with current rating 1.5 amperes and plating options
1.5mm -40℃~+105℃ 1.5A Copper alloy 100V 2x4P 4 2 2.54mm P=1.27mm(Staggered Pins) Free Hanging, Panel Mount RoHS
connection solution CONNFLY Elec DS1017-14MA2B with thermoplastic insulator and copper alloy contacts
Connector 14 position 2mm
Gray housing CONNFLY Elec DS1011-14RBSiA7-B connector with V T type housing and special latch options
Connector IDC Header Through Hole, Right Angle 14 position 2.54mm
Send RFQ
Stock:
MOQ: