Electrical connection solution hanxia HX DC005C-1.3 QT DC power jack rated 30V 1.0A for power supply
Specifications
Mounting Type:
弯插
Connector Type:
DC电源插座
Rated Current:
1A
Working Temperature:
-25℃~+70℃
Rated Voltage:
30V
Inside Contact Diameter:
1.3mm
Outside Contact Diameter:
3.9mm
Mfr. Part #:
HX DC005C-1.3 QT
Package:
Through Hole
Model Number:
HX DC005C-1.3 QT
Introduction
DC Power Jack - HX DC005C-1.3 QT
The HX DC005C-1.3 QT is a DC power jack designed for reliable electrical connections. It is suitable for various applications requiring a 30V DC, 1.0A rating. The product is manufactured by Shenzhen Hanxia Electronic Co., Ltd.
Product Attributes
- Brand: Hanxia
- Origin: Shenzhen, China
- Model: HX DC005C-1.3 QT
Technical Specifications
| Item | Specification | Test Condition |
| Electrical Characteristics | Rated Voltage: 30V DC | |
| Rated Current: 1.0A | ||
| Contact Resistance: 30m MAX | Measured at 1KHz small current | |
| Insulation Resistance: 100M Min | DC 500V potential across terminals and frame for 1 minute | |
| Withstand Voltage: 500V AC | AC 500V (50/60Hz) across terminals and frame for 1 minute, no breakdown | |
| Mechanical Performance | Mate Force: 3-20N | Measured with force gauge between plug and spring piece |
| Unmate Force: 3-20N | Measured with force gauge between plug and spring piece | |
| Durability: 5000 Cycles | 20-30 cycles/minute, no load | |
| Temperature Range | -25 ~ +70 | Normal operating environment |
| Environmental Conditions | Operating Temperature: 5~35 | Humidity: 45~85% RH |
| Storage Temperature: -25~70 | ||
| Soldering Test | Terminal dipping in solder bath at 2305 for 3sec (2mm depth) | |
| Life Test | Contact Resistance: 40m max | After 5000 cycles |
| Drive Force: within 30% of initial value | After 5000 cycles | |
| Heat Test | Contact Resistance: 50m max | After 48 hours at 802, then 30 min in normal condition |
| Insulation Resistance: 100M min | After 48 hours at 802, then 30 min in normal condition | |
| Mechanical/Electrical Integrity | After 48 hours at 802, then 30 min in normal condition | |
| Humidity Test | Mechanical/Electrical Integrity | After 48 hours at 402 and 90-95% RH, then 30 min in normal condition |
| Cold Test | Mechanical/Electrical Integrity | After 48 hours at -302, then 30 min in normal condition |