Rectangular 2mm Pitch Connectors Harwin M80-0130001 Male Female Cable Board Interconnection Solutions
Product Overview
A range of 2mm pitch male and female rectangular, fully shrouded unsealed connectors with replaceable contacts for interconnecting board to board, cable to board and cable to cable. The range covers 2 to 96 ways, in various application methods. Female connectors are available for crimp, vertical throughboard and surface mount termination. Male connectors are available for crimp, vertical or horizontal (90) throughboard and surface-mount termination. Pre-cabled contacts and cable assemblies are also available in various options. The connectors are provided with a range of contact terminations that are gold or tin plated. The connector is intended for use as a low voltage connector in high packing density electronic equipment. The connector is polarised to prevent mis-matching and can be produced with a latching feature (L-Tek) or in a jackscrew (J-Tek) format, with or without board mounting. L-Tek and J-Tek connectors are available with low-frequency (LF) contacts, while mixed technology (Mix-Tek) connectors are also available with jackscrews, with a choice of power or coax contacts. Some connector styles are available manufactured and tested to BS9525 F0033.
Product Attributes
- Brand: HARWIN
- Series: Datamate M80 & M83 Series
- Certifications: BS9525 F0033 (some styles)
Technical Specifications
| Specification | Details |
| Environmental Classification | 55/125/56 Days at 95% RH |
| Operating Temperature Range | -55C to +125C |
| Low Air Pressure Severity | 300 mbar (9,144m/30,000ft) up to 360V DC |
| Salt Spray (L-Tek) | BS2011 Part 2.1Kb Severity 2 (5% Solution, 6.5/7.2pH @ 40C, 93% Humidity for 66 hours) |
| Salt Spray (J-Tek & Mix-Tek) | EIA364 Test Procedure 26 condition A (5% Solution, 6.5/7.2pH @ 35C, 95% Humidity for 96 hours) |
| Vibration Severity (Standard Signal Contact, 10G test) | 10Hz to 2,000Hz, 0.75mm, 98m/s (10G), duration 6 hours |
| Vibration Severity (Standard Signal Contact, 20G test) | 10Hz to 81.73Hz, 1.5mm peak-to-peak; 57.55Hz to 2,000Hz, 196.2m/s (20G), duration 2 hours |
| Shock Severity (Standard Signal Contact) | 981m/s (100G), 18 shocks total |
| Bump Severity (Standard Signal Contact) | 390m/s (40G), 4,00010 bumps |
| Vibration Severity (T-Contact) | 10Hz to 13.6Hz, 35mm peak-to-peak, 13.6Hz to 41.6Hz, 1.5mm peak-to-peak, 41.6Hz to 2,000Hz, 392.4m/s (40G), duration 6 hours |
| Shock Severity (T-Contact) | 981m/s (100G) |
| Clip Retention in Body | 18N min (10N min from a sample of 10 sockets, providing the average of the samples is 22N) |
| High Temperature, Long Term | 1,000 hours at 85C (current as in 2.1.1.) |
| High Temperature, Short Term | 250 hours at 125C (no electrical load) |
| Contact Retention in Housing | 10N min |
| Contact Replacement in Housing (Male Crimp Jackscrew) | 2 operations at 10N |
| Durability (Standard Signal Contact) | 500 operations |
| Durability (T-Contact) | 1,000 operations |
| Contact holding force (Standard Signal Contact) | 0.2N min |
| Insertion Force (per contact, M80 Standard Signal Contact) | 2.0N max |
| Insertion Force (per contact, M83 Signal Contact) | 1.0N max |
| Insertion Force (per contact, T-Contact) | 4.0N max |
| Withdrawal Force (per contact, M80 Standard Signal Contact) | 0.2N min |
| Withdrawal Force (per contact, M83 Signal Contact) | 0.2N min |
| Withdrawal Force (per contact, T-Contact) | 0.5N min |
| Cable Contact Replacement in Housing | up to 2 times max |
| Contact Wipe (T-Contact) | 2.00mm min |
| Coax Impedance | 50 |
| Coax Frequency Range | 6GHz (dependent on cable type or board layout) |
| Coax VSWR (M80-310) | 1.19 + (0.04 x Frequency) GHz max |
| Coax VSWR (Others) | 1.05 + (0.04 x Frequency) GHz max |
| Coax Voltage Rating | 180V AC at 500mA |
| Coax Voltage Proof | (Data incomplete in source) |
| Low-Frequency Signal Contact Current Rating (Standard, 1 loaded, 25C) | 3.3A max |
| Low-Frequency Signal Contact Current Rating (Standard, 1 loaded, 85C) | 2.6A max |
| Low-Frequency Signal Contact Current Rating (Standard, all contacts, 25C) | 3.0A max |
| Low-Frequency Signal Contact Current Rating (Standard, all contacts, 85C) | 2.2A max |
| Low-Frequency Signal Contact Current Rating (T-Contact, 1 loaded, 25C) | 8.5A max |
| Low-Frequency Signal Contact Current Rating (T-Contact, 1 loaded, 85C) | 6.5A max |
| Low-Frequency Signal Contact Current Rating (T-Contact, all contacts, 25C) | 3.5A max |
| Low-Frequency Signal Contact Current Rating (T-Contact, all contacts, 85C) | 2.6A max |
| Low-Frequency Signal Contact Current Rating (Flex Circuit Assembly, individual track, 25C) | 1.0A max |
| Low-Frequency Signal Working Voltage (Pre-Cabled & Cable Assemblies) | 300V DC or AC peak |
| Low-Frequency Signal Working Voltage (Others) | 800V DC or AC peak |
| Low-Frequency Signal Voltage Proof | 1,200V DC or AC peak |
| Low-Frequency Signal Contact Resistance (Initial) | 20m max |
| Low-Frequency Signal Contact Resistance (After Conditioning) | 25m max |
| Low-Frequency Signal Insulation Resistance (Initial) | 1,000M min |
| Low-Frequency Signal Insulation Resistance (Hot After Conditioning) | 100M min |
| Low-Frequency Signal Creepage Path contact-to-contact | 0.35mm min |
| Low-Frequency Signal Air Gap contact-to-contact | 0.35mm min |
| Wire Termination Range (Recommended Wire Type) | See Component Specification C049XX (latest issue) |
| Wire Termination (Extra Small Bore, AWG 32) | 7/0.08, 4.0N pull-off, Crimp tool setting 4, Max. insulation diameter (Data incomplete in source) |
| Wire Termination (Extra Small Bore, AWG 30) | 1/0.25, 7.0N pull-off, Crimp tool setting 4, Max. insulation diameter (Data incomplete in source) |
| Wire Termination (Extra Small Bore, AWG 28) | 7/0.12, 12.5N pull-off, Crimp tool setting 5, Max. insulation diameter (Data incomplete in source) |
| Wire Termination (Small Bore, AWG 28) | 7/0.12, 12.5N pull-off, Crimp tool setting 6, Max. insulation diameter (Data incomplete in source) |
| Wire Termination (Small Bore, AWG 26) | 7/0.15, 25.0N pull-off, Crimp tool setting 6, Max. insulation diameter (Data incomplete in source) |
| Wire Termination (Small Bore, AWG 24) | 7/0.2, 44.0N pull-off, Crimp tool setting 6, Max. insulation diameter (Data incomplete in source) |
| Wire Termination (Large Bore, AWG 22) | 19/0.15, 50.0N pull-off, Crimp tool setting 6, Max. insulation diameter (Data incomplete in source) |
| Wire Termination (T-Contact, AWG 22) | 19/0.15, 50.0N pull-off, Crimp tool setting 6, Max. insulation diameter (Data incomplete in source) |
2411041650_Harwin-M80-0130001_C3264847.pdf