Home > Products > FFC, FPC (Flat Flexible) Connector Assemblies >FFC, FPC (Flat Flexible) Connector Assemblies > connector HRS FH52-32S-0.5SH suitable for electrical connections in varied temperature environments

connector HRS FH52-32S-0.5SH suitable for electrical connections in varied temperature environments

Manufacturer:
HRS
Description:
FFC/FPC Connector 32 Position 0.5mm Pitch Bottom Contact Surface Mount, Right Angle -40℃~+105℃
Category:
FFC, FPC (Flat Flexible) Connector Assemblies/FFC, FPC (Flat Flexible) Connector Assemblies
Specifications
Operating Temperature:
-40℃~+105℃
Locking Feature:
翻盖式
Number Of Contacts:
32P
Pitch:
0.5mm
Contact Type:
下接
Mounting Type:
卧贴
FFC, FCB Thickness:
0.3mm
Contact Plating:
Contact Material:
磷青铜
Mfr. Part #:
FH52-32S-0.5SH
Package:
SMD,P=0.5mm,Surface Mount,Right Angle
Model Number:
FH52-32S-0.5SH
Introduction

Product Overview

This product is a connector designed for reliable electrical connections. It operates within a wide temperature range and is suitable for applications requiring specific humidity and current ratings. The connector undergoes rigorous testing to ensure its performance and durability under various environmental and mechanical stresses.

Product Attributes

  • Brand: HIROSE ELECTRIC CO., LTD.
  • Part Number: FH52-**S-0.5SH
  • Code Number: CL580
  • Drawing Number: ELC4-328248-00
  • Revision Date: 15.07.25
  • Copyright: Sep.1.2023 HIROSE ELECTRIC CO., LTD.

Technical Specifications

ITEMTEST METHODREQUIREMENTSQTAT
APPLICABLE STANDARD OPERATING TEMPERATURE RANGE-40 C TO 105 C
STORAGE TEMPERATURE RANGE-10 C TO 50 C (PACKED CONDITION)
RATING VOLTAGE50 V AC / DC
OPERATING OR STORAGE HUMIDITY RANGERELATIVE HUMIDITY90 % MAX (NOT DEWED)
CURRENT0.5 A (note 1)
APPLICABLE CABLEt=0.30.05mm, GOLD PLATING
GENERAL EXAMINATIONVISUALLY AND BY MEASURING INSTRUMENT. ACCORDING TO DRAWING.
MARKINGCONFIRMED VISUALLY.
CONTACT RESISTANCE1mA(DC OR 1000Hz). BULK RESISTANCE (L=8mm)50 m MAX. INCLUDING FPC,FFC
INSULATION RESISTANCE100 V DC.500 M MIN.
VOLTAGE PROOF150 V AC FOR 1 min.NO FLASHOVER OR BREAKDOWN.
MECHANICAL OPERATION20 TIMES INSERTIONS AND EXTRACTIONS. CONTACT RESISTANCE: 50 m MAX. NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
VIBRATIONFREQUENCY 10 TO 55 Hz, HALF AMPLITUDE 0.75 mm, FOR 10 CYCLES IN 3 DIRECTIONS. NO ELECTRICAL DISCONTINUITY OF 1 s. CONTACT RESISTANCE: 50 m MAX. NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
SHOCK981 m/s2 , DURATION OF PULSE 6 ms AT 3 TIMES IN 3 DIRECTIONS.
FPC RETENSION FORCEMEASURED BY APPLICABLE FPC. (CONNECTOR,FPC AT INITIAL CONDITION. THICKNESS OF FPC SHALL BE t=0.30mm ) DIRECTION OF INSERTION:0.4n N MIN ( n : NUMBER OF CONTACTS).
RAPID CHANGE OF TEMPERATURETEMPERATURE-40+15TO+35+105+15TO+35C TIME 30 2 TO 3 30 2 TO 3 min. UNDER 5 CYCLES. CONTACT RESISTANCE: 50 m MAX. INSULATION RESISTANCE: 50 M MIN. NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
DAMP HEAT (STEADY STATE)EXPOSED AT 402 C, RELATIVE HUMIDITY 90 TO 95 %, 96 h.
DAMP HEAT,CYCLICEXPOSED AT -10 TO +65 C, RELATIVE HUMIDITY 90 TO 96 %, 10 CYCLES,TOTAL 240 h. CONTACT RESISTANCE: 50 m MAX. INSULATION RESISTANCE: 1 M MIN. (AT HIGH HUMIDITY) INSULATION RESISTANCE: 50 M MIN. (AT DRY) NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
DRY HEATEXPOSED AT 1052 C, 96 h. CONTACT RESISTANCE: 50 m MAX. NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
COLDEXPOSED AT -403C, 96 h.
CORROSION SALT MISTEXPOSED AT 352 C 5% SALT WATER SPRAY FOR 96 h. CONTACT RESISTANCE: 50 m MAX. NO EVIDENCE OF CORROSION WHICH AFFECTS TO OPERATION OF CONNECTOR.
SURPHUR DIOXIDE [JIS C 60068-2-42]EXPOSED AT 402 C , RELATIVE HUMIDITY 805% , 255 PPM FOR 96 h.
HYDROGEN SULPHIDE [JIS C 60068-2-43]EXPOSED AT 402 C , RELATIVE HUMIDITY 805% , 10 TO 15 PPM FOR 96 h.
RESISTANCE TO SOLDERING HEAT1) REFLOW SOLDERING (TO BE 2 TIMES MAX.) PEAK TMP. 250 C MAX REFLOW TMP. 230 C MIN FOR 30 sec. PRE-HEATING. 150 TO 200C 90 TO 120 sec. SOLDERING IRONS : 350 10 C, FOR 5 1 sec .NO DEFORMATION OF CASE OF EXCESSIVE LOOSENESS OF THE TERMINALS.
SOLDERABILITYSOLDERED AT SOLDER TEMPERATURE, 2355 C FOR IMMERSION DURATION, 20.5 sec.A NEW UNIFORM COATING OF SOLDER SHALL COVER A MINIMUM OF 95 % OF THE SURFACE BEING IMMERSED.

Note: Unless otherwise specified, refer to IEC 60512. (note 1) WHEN THE SAME VALUE OF CURRENT ARE APPLID TO ALL CONTACTS AT THE SAME TIME IN ONCE, SET THE CURRENT TO THE 70 % OF THE RATED CURRENT VALUE.


2411220641_HRS-FH52-32S-0-5SH_C6619632.pdf

Send RFQ
Stock:
MOQ: