automotive connector HRS DF50A-12S-1C with strong electrical current capacity and mechanical durability
Product Overview
This product is a connector designed for high reliability applications, particularly suitable for automotive equipment and devices. It offers robust electrical and mechanical characteristics, along with reliable performance under various environmental conditions.
Product Attributes
- Brand: Hirose Electric Co., Ltd.
- Origin: Japan (implied by copyright and company name)
Technical Specifications
| Item | Test Method | Requirements | QT | AT |
|---|---|---|---|---|
| Operating temperature range | -35C to +85C (Note 1) | X | X | |
| Storage temperature range | -10C to +60C (Note 3) | X | ||
| Operating humidity range | 20% to 80% (Note 2) | X | X | |
| Storage humidity range | 40% to 70% (Note 3) | X | ||
| Voltage | AC/DC | 100V | ||
| Applicable connector | DF50A-*P-1V(##) DF50A-*P-1H(##) | |||
| Current (Contact 1) | 3 to 16A | |||
| Applicable Contact | DF50-26SCFA(##) DF50-2830SCFA(##) DF50K-2830SCFA(##) DF50-3032SCFA(##) | |||
| Current (Contact 2) | AWG26 | 2.0A | X | X |
| Current (Contact 2) | AWG28 | 2.0A | X | X |
| Current (Contact 3) | AWG30 | 0.9A | X | X |
| Current (Contact 4) | AWG32 | 0.7A | X | X |
| Insulation resistance | 100V DC | 500M MIN. | X | |
| Voltage proof | 300V AC for 1 min | No flashover or breakdown. | X | |
| Mechanical operation | 30 times insertions and extractions | No damage, crack or looseness of parts. | X | |
| Vibration | Frequency 10 to 55 Hz, single amplitude 0.75 mm, at 10 cycles for each, for 3 directions. | X | ||
| Shock | 490 m/s duration of pulse 11 ms At 3 times for 3 directions. | X | ||
| Damp heat (Steady state) | Exposed at 40 2 C, 90 to 95 %, 96 h. | Insulation resistance: 100M MIN. No damage, crack or looseness of parts. | X | |
| Rapid change of temperature | Temperature -55+85 Time 30 30min. Under 5 cycles. (The transferring time of the tank is 2 to 3 min) | Insulation resistance: 500M MIN. No damage, crack or looseness of parts. | X |
Notes:
Note 1: Include the temperature rising by current.
Note 2: No condensing.
Note 3: Apply to the condition of long term storage for unused products before harness assembly. After harness assembly, operating temperature and humidity range is applied for interim storage during transportation.
2410121614_HRS-DF50A-12S-1C_C570425.pdf