High Reliability OMRON XC5A3222A Connector with 0.4 Micron Gold Plated Contacts and UL CSA Certification
Product Overview
The XC5 DIN Twin-contact Connectors offer a wide variety of DIN connectors that conform to UL/CSA standards. They fully preserve the characteristics of normal DIN connectors while increasing terminal availability, catering to almost any application with a product range from one-piece to two-piece connectors. Featuring a twin-contact system for high reliability and lower insertion force due to FEM analysis, these connectors meet world market needs.
Product Attributes
- Brand: OMRON
- Certifications: UL/CSA Standards, RoHS Compliant
- Material (Housings): Fiber-glass reinforced PBT resin (UL94 V-0)/gray
- Material (Contacts - Mating end): Brass/nickel base, 0.4-m gold plating
- Material (Contacts - Terminal): Phosphor bronze/nickel base, 0.4-m gold plating
- Material (Terminal): Brass/nickel base, 2.0-m tin plating
- Material (Terminal - Wrap): Phosphor bronze/nickel base, 2.0-m tin plating
- Color (Housings): Gray
Technical Specifications
| Product Series | Type | No. of Contacts | Rated Current | Rated Voltage | Contact Resistance | Insulation Resistance | Dielectric Strength | Total Insertion Force | Removal Force | Insertion Durability | Ambient Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
| XC5A (Double-row Plugs) | DIN B-type (Standard) | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C (with no icing at low temperature) |
| XC5A (Double-row Plugs) | DIN B-type (Standard) | 32 | |||||||||
| XC5A (Double-row Plugs) | DIN B-type (Standard) | 44* | |||||||||
| XC5A (Double-row Plugs) | DIN B-type (Standard) | 50* | |||||||||
| XC5A (Double-row Plugs) | DIN B-type (Standard) | 64 | |||||||||
| XC5A (Double-row Plugs) | DIN B-type (Standard) | 100* | |||||||||
| XC5B (Double-row Sockets) | DIN B-type (Standard) | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C (with no icing at low temperature) |
| XC5B (Double-row Sockets) | DIN B-type (Standard) | 32 | |||||||||
| XC5B (Double-row Sockets) | DIN B-type (Standard) | 44* | |||||||||
| XC5B (Double-row Sockets) | DIN B-type (Standard) | 50* | |||||||||
| XC5B (Double-row Sockets) | DIN B-type (Standard) | 64 | |||||||||
| XC5B (Double-row Sockets) | DIN B-type (Standard) | 100* | |||||||||
| XC5E (Double-row Plugs) | DIN Q-type (Reverse) | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C (with no icing at low temperature) |
| XC5E (Double-row Plugs) | DIN Q-type (Reverse) | 32 | |||||||||
| XC5E (Double-row Plugs) | DIN Q-type (Reverse) | 44* | |||||||||
| XC5E (Double-row Plugs) | DIN Q-type (Reverse) | 50* | |||||||||
| XC5E (Double-row Plugs) | DIN Q-type (Reverse) | 64 | |||||||||
| XC5E (Double-row Plugs) | DIN Q-type (Reverse) | 100* | |||||||||
| XC5F (Double-row Sockets) | DIN Q-type (Reverse) | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C (with no icing at low temperature) |
| XC5F (Double-row Sockets) | DIN Q-type (Reverse) | 32 | |||||||||
| XC5F (Double-row Sockets) | DIN Q-type (Reverse) | 44* | |||||||||
| XC5F (Double-row Sockets) | DIN Q-type (Reverse) | 50* | |||||||||
| XC5F (Double-row Sockets) | DIN Q-type (Reverse) | 64 | |||||||||
| XC5F (Double-row Sockets) | DIN Q-type (Reverse) | 100* | |||||||||
| XC5C (Triple-row Plugs) | DIN C-type (Standard) | 32* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C (with no icing at low temperature) |
| XC5C (Triple-row Plugs) | DIN C-type (Standard) | 48 | |||||||||
| XC5C (Triple-row Plugs) | DIN C-type (Standard) | 64* | |||||||||
| XC5C (Triple-row Plugs) | DIN C-type (Standard) | 96 | |||||||||
| XC5D (Triple-row Sockets) | DIN C-type (Standard) | 32* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C (with no icing at low temperature) |
| XC5D (Triple-row Sockets) | DIN C-type (Standard) | 48 | |||||||||
| XC5D (Triple-row Sockets) | DIN C-type (Standard) | 64* | |||||||||
| XC5D (Triple-row Sockets) | DIN C-type (Standard) | 96 | |||||||||
| XC5G (Triple-row Plugs) | DIN R-type (Reverse) | 48 | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C (with no icing at low temperature) |
| XC5G (Triple-row Plugs) | DIN R-type (Reverse) | 64* | |||||||||
| XC5G (Triple-row Plugs) | DIN R-type (Reverse) | 96 | |||||||||
| XC5H (Triple-row Sockets) | DIN R-type (Reverse) | 48 | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C (with no icing at low temperature) |
| XC5H (Triple-row Sockets) | DIN R-type (Reverse) | 64* | |||||||||
| XC5H (Triple-row Sockets) | DIN R-type (Reverse) | 96 |
2411041600_OMRON-XC5A3222A_C6334090.pdf