Durable Polyamide Upper Housing Phoenix Contact 2907169 Modular Design for DIN Rail Flame Retardant
Product Overview
This is the upper housing for connectors with sockets, designed for DIN rail mounting. It offers tool-free installation and modular expandability with various total widths from 12.5 mm to 90 mm. The housing features diverse connection technologies and is flame-retardant, meeting UL 94 V0 standards. It is suitable for DIN rail installation and can accommodate optional integrated or DIN rail-mounted bus connectors. The ME 22,5 OT-MSTBO GN is an upper housing for modular systems.
Product Attributes
- Brand: Phoenix Contact
- Product Type: Upper Housing
- Housing Type: DIN Rail Housing
- Housing Series: ME
- Product Series: ME 22,5..
- Color (Housing): Green (similar to RAL 6021)
- Flame Retardancy Rating (UL 94): V0
- CTI according to IEC 60112: 600
- Housing Material: Polyamide
- Surface Characteristic: Untreated
- Mounting Type: Locking with lower housing
- Mounting Position: Vertical (on horizontal DIN rail)
- Packaging Type: Cardboard packaging
- Outer Packaging Type: Cardboard box
Technical Specifications
| Specification | Details |
|---|---|
| Model | ME 22,5 OT-MSTBO GN |
| Part Number | 2907169 |
| Description | Upper housing for connectors with sockets |
| Width | 22.6 mm |
| Height | 99 mm |
| Depth | 45.85 mm |
| Depth from base support surface | 38.5 mm |
| PCB Thickness | 1.4 mm ... 1.8 mm |
| Number of rows | 2 |
| Ventilation | No |
| Maximum number of positions | 12 (pitch: 7.25 mm), 16 (pitch: 5 mm), 20 (pitch: 3.5 mm) |
| Kit Includes | 2907444 ME 22,5 OT-MSTBO SET |
| Vibration Test (IEC 60068-2-6:2007-12) | Frequency: 10 - 150 - 10 Hz, Sweep rate: 1 octave/min, Amplitude: 0.15 mm (10 Hz ... 58.1 Hz), Acceleration: 2g (58.1 Hz ... 150 Hz), Test duration per axis: 2.5 h, Test direction: X-, Y- and Z-axis |
| Glow Wire Test (IEC 60695-2-11:2014-02) | Temperature: 850 C, Exposure time: 30 s |
| Heat Stability/Ball Pressure Test (IEC 60695-10-2:2014-02) | Temperature: 125 C, Test duration: 1 h, Force: 20 N |
| Mechanical Strength/Drum Test (DIN EN 60998-1 (VDE 0613-1):2005-03) | Drop height: 50 cm, Frequency: 10 |
| Shock Test (IEC 60068-2-27:2008-02) | Pulse waveform: Half-sine, Acceleration: 15g, Shock duration: 11 ms, Number of shocks per direction: 3, Test direction: X-, Y- and Z-axis (positive and negative) |
| IP Code (IEC 60529:1989-11 + AMD 1:1999-11 + AMD 2:2013-08) | Maximum IP code: IP20 |
| Ambient Temperature (Operation) | -40 C ... 105 C (depending on power loss) |
| Ambient Temperature (Storage/Transport) | -40 C ... 55 C |
| Ambient Temperature (Assembly) | -5 C ... 100 C |
| Relative Humidity (Storage/Transport) | 80 % |
| PCB Mounting Type | Slot |
| Number of PCB supports | 1 |
2404291739_Phoenix-Contact-2907169_C7472179.pdf
feed through terminal block Phoenix Contact 2716716 with CSA EAC cULus recognized certifications
Feed through terminal block with screw connection rated 800 V 57 A Phoenix Contact 2716732 gray color
Feed through terminal block with nominal voltage 800 volt and 57 amp current Phoenix Contact 2716729
| Image | Part # | Description | |
|---|---|---|---|
|
|
feed through terminal block Phoenix Contact 2716716 with CSA EAC cULus recognized certifications |
2x6P 65A Gray 6~24 Barrier Blocks RoHS
|
|
|
|
Feed through terminal block with screw connection rated 800 V 57 A Phoenix Contact 2716732 gray color |
65A Gray 2 5 Barrier Blocks RoHS
|
|
|
|
Feed through terminal block with nominal voltage 800 volt and 57 amp current Phoenix Contact 2716729 |
65A Gray 2 4 Barrier Blocks RoHS
|