This document details the specifications for the TYPE-C 24P GTJB connector from Shenzhen Shouhan Technology Co., Ltd. Designed for reliable performance, it operates within a practical temperature range of -30C to 80C and adheres to standard atmospheric testing conditions. The connector is built to withstand mechanical stresses, including specific insertion and disconnection forces, and offers robust electrical characteristics such as low contact resistance and high insulation resistance. Durability is demonstrated through extensive testing, including solderability, resistance to soldering heat, humidity, heat, cold, and life cycle tests, ensuring consistent performance under various environmental and operational conditions.
Product Attributes
- Brand: SHENZHEN SHOUHAN TECHNOLOGY CO.,LTD ()
- Product Name: TYPE-C
- Model/Part No: TYPE-C 24P GTJB
- Material Code: TYPE-C 24P GTJB
- Origin: Shenzhen, China
Technical Specifications
| Category | Item | Test Conditions | Performance/Specification |
|---|---|---|---|
| RATING () | Rating | - | 20V 5A |
| Practical Temperature Range | - | -30C ~ 80C | |
| STANDARD ATMOSPHERIC CONDITIONS | Temperature | For Measurements and Tests | 5C to 35C |
| Humidity | For Measurements and Tests | 45% to 85% | |
| Pressure | For Measurements and Tests | 86Kpa to 106Kpa | |
| MECHANICAL () | Connection Force | After connecting and disconnecting using standard plug gauge 3 times | 5 ~ 20N |
| Disconnect Force | After connecting and disconnecting using standard plug gauge 3 times | 8 ~ 20N | |
| TERMINAL STRENGTH | Terminal Strength | Static load of 0.1N/m (1kgf/cm) applied to the tip for 1 min in any direction | No damage, looseness, or play; electrical and mechanical characteristics satisfied |
| ELECTRICAL () | Contact Resistance | Measured at small current (100mA or less), 1000Hz | 40m MAX |
| Insulation Resistance | Apply 100V DC for 1 min (between body and conductor; between conductors not to be contact; between conductors not to be when plug is inserted) | 100M MIN | |
| Dielectric Strength | Apply AC 100V (rms, 50~60Hz) for 1 min (trip current: 0.5mA) (between body and conductor; between conductors not to be contact; between conductors not to be when plug is inserted) | Without damage, arcing, or breakdown | |
| DURABILITY () | Solderability Test | Terminals dipped 1mm in solder bath at 2505 for 50.5 seconds | Solder wetting time 3 sec; Soldering area > 75% |
| Resistance to Soldering Heat Test (Reflow) | Preheat: 180 for 120s; Peak temperature: 2605 within 20 seconds | No deformation of case or excessive looseness of terminals; electrical characteristics satisfied | |
| Resistance to Soldering Heat Test (Soldering Iron) | Soldering Iron Method | Bit temperature 3305, application time 30.5 sec, no excessive pressure on terminal | No deformation of case or excessive looseness of terminals; electrical characteristics satisfied |
| Humidity Test | Humidity | Stored at 402 and 90% to 96% humidity for 96 Hr, then maintained at standard atmospheric condition for 1 Hr | No damage on appearance; mechanical and electrical characteristics satisfied |
| Heat Test | Heat | Stored at 702 for 96 hours, then subjected to controlled recovery for 1 Hr | No damage on appearance; mechanical and electrical characteristics satisfied |
| Cold Test | Cold | Stored at -253 for 96 hours, then subjected to controlled recovery for 1 Hr | No damage on appearance; mechanical and electrical characteristics satisfied |
| Life Test | Without Load | Connection and disconnection for 10000 cycles at a speed of 10 to 25 cycles/min | - |
| With Load (Rating Condition, Non-Inductive Load) | Connection and disconnection for 10000 cycles at a speed of 10 to 20 cycles/min | - | |
| Performance Criteria (With Load) | - | Contact Resistance 0.1; Disconnection Force 0.8 to 2.0N; Mechanical and electrical characteristics satisfied | |
| Temperature Cycling Test | Temperature Cycling | 5 cycles of specified conditions (e.g., 8 hours at 70, followed by 8 hours at -20), then 30 minutes in room ambient | No deformation or cracks in molded part; Insertion & Extraction Force: 3 to 20N; Contact Resistance: MAX.30m; Insulation Resistance: MIN.100 M; Dielectric Withstanding Voltage: 100VAC/min (between terminals) |
| Cold & Heat Shock Test | Cold & Heat Shock | 5 cycles of specified conditions (e.g., 1 hour at 70, followed by 1 hour at -20), then 30 minutes in room ambient | No deformation or cracks in molded part; Insertion & Extraction Force: 3 to 25N; Contact Resistance: MAX.30m; Insulation Resistance: MIN.100 M; Dielectric Withstanding Voltage: 500VAC/min (between terminals) |