wiring terminals 3M MV10-8FLX-BOTTLE designed for easy insulation entry and wire twisting prevention
3M Scotchlok Terminals
3M Scotchlok terminals are a premier line designed for a variety of insulation types, including heat shrink, nylon, vinyl, and non-insulated options. They feature various barrel styles such as butted, brazed, seamless, or interlocking barrels, and are available in bottle or bulk packaging. These terminals are known for their effective and reliable performance, with design features that ensure easy installation, including positive and easy wire insertion, elimination of strand hang-ups and wire twisting, and easy insulation entry, making the installer's job easier.
Product Attributes
- Brand: 3M Scotchlok
- Product Families: 3M Scotchlok Terminals, 3M Highland Terminals
- Insulation Materials: Heat Shrink, Nylon, Vinyl, Non-Insulated
- Barrel Styles: Butted, Brazed, Seamless, Interlocking
- Packaging Options: Bottle, Bulk, Bag
- RoHS Compliant: 2011/65/EU
Technical Specifications
| Product Name | Conductor Size | Stud Size | Barrel Style | Insulation Material | Order No. | Terminals per Carton | Terminals per Case |
|---|---|---|---|---|---|---|---|
| 3M Scotchlok Ring Tongues (Heat Shrink Brazed Seam) | 22 - 18 AWG | 6 | Brazed | Heat Shrink | MH18-6R/LK | - | 250 |
| 3M Scotchlok Ring Tongues (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | 4 | Butted | Nylon with Insulation Grip | MNG18-4R/SK | - | 1000 |
| 3M Scotchlok Ring Tongues (Nylon Insulated Brazed Seam) | 4 AWG | 10 | Brazed | Nylon | MN4-10RK | - | 200 |
| 3M Scotchlok Ring Tongues (Vinyl Insulated Brazed Seam) | 22 - 18 AWG | 4 | Brazed | Vinyl | MV18-4R/SX | 100 | 500 |
| 3M Scotchlok Ring Tongues (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted | Vinyl | MVU18-6R/SK | - | 1000 |
| 3M Scotchlok Ring Tongues (Non-Insulated Brazed Seam) | 22 - 18 AWG | 6 | Brazed | Non-Insulated | M18-6R/SK | - | 1000 |
| 3M Scotchlok Ring Tongues (Non-Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted | Non-Insulated | MU18-6R/SK | - | 1000 |
| 3M Scotchlok Multi-Stud Ring Tongues (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | 6 - 10 | Butted | Nylon with Insulation Grip | MNG18-610RX | 100 | 500 |
| 3M Scotchlok Compression Lug Ring Tongues (Non-Insulated Copper Seamless) | 2 AWG | 1/4" | Seamless | Non-Insulated | MC2-14RX | 10 | 100 |
| 3M Scotchlok Standard Forks (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | 6 | Butted | Nylon with Insulation Grip | MNG18-6FX | 100 | 500 |
| 3M Scotchlok Standard Forks (Vinyl Insulated Brazed Seam) | 22 - 18 AWG | 6 | Brazed | Vinyl | MV18-6FX | 100 | 500 |
| 3M Scotchlok Standard Forks (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted | Vinyl | MVU18-6FX | 100 | 500 |
| 3M Scotchlok Standard Forks (Non-Insulated Brazed Seam) | 22 - 18 AWG | 6 | Brazed | Non-Insulated | M18-6FX | 100 | 500 |
| 3M Scotchlok Standard Forks (Non-Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted | Non-Insulated | MU18-6FK | - | 1000 |
| 3M Scotchlok Block Forks (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | 6 | Butted | Nylon with Insulation Grip | MNG18-6FB/SX | 100 | 500 |
| 3M Scotchlok Block Forks (Vinyl Insulated Brazed Seam) | 22 - 18 AWG | 6 | Brazed | Vinyl | MV18-6FB/SX | 100 | 500 |
| 3M Scotchlok Block Forks (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted | Vinyl | MVU18-6FB/SX | 100 | 500 |
| 3M Scotchlok Block Forks (Non-Insulated Brazed Seam) | 22 - 18 AWG | 6 | Brazed | Non-Insulated | M18-6FB/SX | 100 | 500 |
| 3M Scotchlok Block Forks (Non-Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted | Non-Insulated | MU18-6FB/SK | - | 1000 |
| 3M Scotchlok Flanged Block Forks (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | 6 | Butted | Nylon with Insulation Grip | MNG18-6FFB/SX | 100 | 500 |
| 3M Scotchlok Flanged Block Forks (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted | Vinyl | MVU18-6FFBK | - | 1000 |
| 3M Scotchlok Flanged Block Forks (Non-Insulated Brazed Seam) | 16 - 14 AWG | 10 | Brazed | Non-Insulated | M14-10FFBK | - | 1000 |
| 3M Scotchlok Flanged Block Forks (Non-Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted | Non-Insulated | MU18-6FFBK | - | 1000 |
| 3M Scotchlok Locking Forks (Heat Shrink Brazed Seam) | 22 - 18 AWG | 6 | Brazed | Heat Shrink | MH18-6FLK | - | 250 |
| 3M Scotchlok Locking Forks (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | 4 | Butted | Nylon with Insulation Grip | MNG18-4FLK | - | 1000 |
| 3M Scotchlok Locking Forks (Vinyl Insulated Brazed Seam) | 22 - 18 AWG | 4 | Brazed | Vinyl | MV18-4FLK | - | 1000 |
| 3M Scotchlok Locking Forks (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 4 | Butted | Vinyl | MVU18-4FLK | - | 1000 |
| 3M Scotchlok Locking Forks (Non-Insulated Brazed Seam) | 22 - 18 AWG | 6 | Brazed | Non-Insulated | M18-6FLK | - | 1000 |
| 3M Scotchlok Locking Forks (Non-Insulated Butted Seam) | 22 - 18 AWG | 4 | Butted | Non-Insulated | MU18-4FLK | - | 1000 |
| 3M Scotchlok Butt Connectors (Heat Shrink Seamless) | 22 - 18 AWG | N/A | Seamless | Heat Shrink | MH18BCK | - | 250 |
| 3M Scotchlok Butt Connectors (Nylon Fully Insulated with Insulation Grip) | 22 - 18 AWG | N/A | Butted | Nylon with Insulation Grip | MNG18BCK | - | 1000 |
| 3M Scotchlok Butt Connectors (Nylon Insulated with Insulation Grip Grease Filled) | 22 - 18 AWG | N/A | Butted | Nylon with Insulation Grip | MNG18BCMK-A | - | 1000 |
| 3M Scotchlok Butt Connectors (Vinyl Insulated Seamless) | 22 - 18 AWG | N/A | Seamless | Vinyl | MV18BCK | - | 1000 |
| 3M Scotchlok Butt Connectors (Vinyl Insulated Brazed Seam) | 8 AWG | N/A | Brazed | Vinyl | MV8BCK | - | 200 |
| 3M Scotchlok Butt Connectors (Vinyl Insulated Butted Seam) | 22 - 18 AWG | N/A | Butted | Vinyl | MVU18BCK | - | 1000 |
| 3M Scotchlok Butt Connectors (Non-Insulated Seamless) | 22 - 18 AWG | N/A | Seamless | Non-Insulated | M18BCK | - | 1000 |
| 3M Scotchlok Butt Connectors (Non-Insulated Seamless Compression) | 2 AWG | N/A | Seamless | Non-Insulated | MC2BCX | 10 | 100 |
| 3M Scotchlok Butt Connectors (Non-Insulated Brazed Seam) | 8 AWG | N/A | Brazed | Non-Insulated | M8BCK | - | 200 |
| 3M Scotchlok Butt Connectors (Non-Insulated Butted Seam) | 22 - 18 AWG | N/A | Butted | Non-Insulated | MU18BCX | 100 | 500 |
| 3M Scotchlok Female Disconnects (Heat Shrink Nylon Fully Insulated) | 22 - 18 AWG | 0.250" | Butted | Heat Shrink | MNHU18-250DFIX | 25 | 125 |
| 3M Scotchlok Female Disconnects (Nylon Fully Insulated with Insulation Grip Interlock Barrel) | 22 - 18 AWG | 0.250" | Interlock Barrel | Nylon with Insulation Grip | MNGI18-250DFIX | 100 | 500 |
| 3M Scotchlok Female Disconnects (Nylon Fully Insulated with Insulation Grip) | 22 - 18 AWG | 0.187" | Butted | Nylon with Insulation Grip | MNG18-187DFIX | 100 | 500 |
| 3M Scotchlok Female Disconnects (Nylon Fully Insulated Butted Seam) | 22 - 18 AWG | 0.250" | Butted | Nylon | MNU18-250DFIX | 100 | 500 |
| 3M Scotchlok Female Disconnects (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | 0.250" | Butted | Nylon | MNG18-250DFX | 100 | 500 |
| 3M Scotchlok Female Disconnects (Nylon Insulated with Insulation Grip Bullet Style) | 22 - 18 AWG | 0.156" | Butted | Nylon | MNG18-156DFIK-A | - | 1000 |
| 3M Scotchlok Female Disconnects (Vinyl Insulated Interlock Barrel) | 22 - 18 AWG | 0.250" | Interlock Barrel | Vinyl | MVI18-250DFX | 100 | 500 |
| 3M Scotchlok Female Disconnects (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 0.187" | Butted | Vinyl | MVU18-187DFX | 100 | 500 |
| 3M Scotchlok Female Disconnects (Non-Insulated Interlock Barrel) | 12 - 10 AWG | 0.250" | Interlock Barrel | Non-Insulated | MI10-250DFX | 50 | 500 |
| 3M Scotchlok Female Disconnects (Non-Insulated Butted Seam) | 26 - 20 AWG | 0.110" | Butted | Non-Insulated | MU20-110/32DFK-A | - | 1000 |
| 3M Scotchlok Female Disconnects (Non-Insulated Butted Seam Flag) | 22 - 18 AWG | 0.187" | Butted | Non-Insulated | MU18-187DF/FLAGX | 100 | 500 |
| 3M Scotchlok Male Disconnects (Heat Shrink Nylon Fully Insulated) | 22 - 18 AWG | 0.250" | Butted | Heat Shrink | MNHU18-250DMIX | 25 | 125 |
| 3M Scotchlok Male Disconnects (Nylon Fully Insulated with Insulation Grip) | 22 - 18 AWG | 0.187" | Butted | Nylon with Insulation Grip | MNG18-187DMIX | 100 | 500 |
| 3M Scotchlok Male Disconnects (Nylon Fully Insulated Butted Seam) | 22 - 18 AWG | 0.187" | Butted | Nylon | MNU18-187DMIX | 100 | 500 |
| 3M Scotchlok Male Disconnects (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | 0.187" | Butted | Nylon | MNG18-187DMK | - | 1000 |
| 3M Scotchlok Male Disconnects (Nylon Insulated with Insulation Grip Bullet Style) | 22 - 18 AWG | 0.156" | Butted | Nylon | MNG18-156DMK-A | - | 1000 |
| 3M Scotchlok Male Disconnects (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 0.187" | Butted | Vinyl | MVU18-187DMX | 100 | 500 |
| 3M Scotchlok Male Disconnects (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 0.187" | Butted | Vinyl | MVU18-187DMK | - | 1000 |
| 3M Scotchlok Male Disconnects (Non-Insulated Butted Seam) | 22 - 18 AWG | 0.187" | Butted | Non-Insulated | MU18-187DMX | 100 | 500 |
| 3M Scotchlok Piggy-Back Disconnects (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | 0.250" | Insulation Grip | Nylon | MNG18-250DMFX-A | 50 | 500 |
| 3M Scotchlok Piggy-Back Disconnects (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 0.250" | Butted Seam | Vinyl | MVU18-250DMFX-A | 100 | 500 |
| 3M Scotchlok Adapters (Non-Insulated Double Male-Female) | N/A | 0.250" | Butted | Non-Insulated | MA250DMFMK-A | - | 500 |
| 3M Scotchlok High Temperature Terminals (Butted Seam 900F Ring Tongues) | 22 - 18 AWG | 6 | Butted | Non-Insulated | MU18-6RHT/SX | 100 | 500 |
| 3M Scotchlok High Temperature Terminals (Butted Seam 900F Standard Forks) | 22 - 18 AWG | 10 | Butted | Non-Insulated | MU18-10FHTK | - | 1000 |
| 3M Scotchlok High Temperature Terminals (Butted Seam 900F Butt Connectors) | 22 - 18 AWG | N/A | Butted | Non-Insulated | MU18BCHTX | 100 | 500 |
| 3M Scotchlok High Temperature Terminals (Butted Seam 900F Female Disconnects) | 16 - 14 AWG | 0.187" | Butted | Non-Insulated | MU14-187DFHTK | - | 1000 |
| 3M Scotchlok High Temperature Terminals (Butted Seam 900F Flag Female Disconnects) | 16 - 14 AWG | 0.250" | Butted | Non-Insulated | MU14-250DFHT/FLAGK | - | 1000 |
| 3M Scotchlok High Temperature Terminals (Butted Seam 900F Male Disconnects) | 16 - 14 AWG | 0.250" | Butted | Non-Insulated | MU14-250DMHTX | 100 | 500 |
| 3M Scotchlok Pin Terminals (Nylon Insulated with Insulation Grip) | 22 - 18 AWG | N/A | Insulation Grip | Nylon | MNG18-47PX-A | 100 | 500 |
| 3M Scotchlok Pin Terminals (Vinyl Insulated Butted Seam) | 22 - 18 AWG | N/A | Butted Seam | Vinyl | MVU18-47PX-A | 100 | 500 |
| 3M Scotchlok Pin Terminals (Non-Insulated Butted Seam) | 22 - 18 AWG | N/A | Butted Seam | Non-Insulated | MU18-47PX-A | 100 | 500 |
| 3M Scotchlok Closed End Connectors | 22 - 16 AWG | N/A | Nylon Insulated | Nylon | S-11-A (BULK) | - | 10000 |
| 3M Scotchlok Parallel Connectors (Vinyl Insulated Butted Seam) | 22 - 18 AWG | N/A | Butted Seam | Vinyl | MVU18PCK | 1000 | - |
| 3M Highland Ring Tongues (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted Seam | Vinyl | RV18-6Q | 25 | N/A |
| 3M Highland Standard Forks (Vinyl Insulated Butted Seam) | 16 - 14 AWG | 6 | Butted Seam | Vinyl | FV14-6Q | 25 | N/A |
| 3M Highland Block Forks (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted Seam | Vinyl | BFV18-6Q | 25 | N/A |
| 3M Highland Locking Forks (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 6 | Butted Seam | Vinyl | LFV18-6Q | 25 | N/A |
| 3M Highland Butt Splices (Vinyl Insulated Butted Seam) | 22 - 18 AWG | N/A | Butted Seam | Vinyl | BSV18Q | 25 | N/A |
| 3M Highland Female Disconnects (Nylon Fully Insulated Butted Seam) | 22 - 18 AWG | 0.187" | Butted Seam | Nylon | FDI18-187Q | 25 | N/A |
| 3M Highland Female Disconnects (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 0.187" | Butted Seam | Vinyl | FDV18-187Q | 25 | N/A |
| 3M Highland Male Disconnects (Nylon Fully Insulated Butted Seam) | 22 - 18 AWG | 0.187" | Butted Seam | Nylon | MTI18-187Q | 25 | N/A |
| 3M Highland Male Disconnects (Vinyl Insulated Butted Seam) | 22 - 18 AWG | 0.187" | Butted Seam | Vinyl | MTV18-187Q | 25 | N/A |
2411201516_3M-MV10-8FLX-BOTTLE_C6121940.pdf