power connection solutions with Anderson Power 115233P13 integrated in SBS X-75A Sealed Connector Series
SBS X-75A Sealed Connector Series
Product Overview
The SBS X-75A Sealed Connector Series offers robust, environmentally sealed power solutions designed for demanding industrial and commercial applications. These connectors provide reliable connections in harsh conditions, protecting against dust, water, and shock with an IP68 weatherproof rating. Key features include positive metal latches to prevent accidental disconnects, integrated cable clamps for strain relief, and a compact, high-power design suitable for outdoor use. With up to 140A power capacity and 5,000 mating cycles, they are ideal for power equipment, material handling, automation, agricultural, construction, and marine environments.
Product Attributes
- Brand: SBS
- Series: X-75A
- Environmental Protection: Dust, Water, Shock
- Ingress Protection: IP68 (up to 30 minutes at 6 feet in mated condition)
- Certifications: UL 1977, UL 60950-1, UL 62368-1, IEC 60529, UL 50E4
- Materials: Housing (PC/PBT), Latches/Screws (Stainless Steel), O-Rings/Grommets (Silicone), Panel Mount Gasket (NBR), Power Contacts (Silver Plated Copper Alloy), Auxiliary Contacts (Gold Plated Copper Alloy)
- Housing Flammability Rating: UL94 V0
- Glow Wire Test: 960C per 60695-2-12
Technical Specifications
| Specification | Details | 4 Pole | 6 Pole |
|---|---|---|---|
| Electrical Current Rating (Amperes) | Power Only | 10A (20 AWG, Signals Energized) | 10A (20 AWG, Signals Energized) |
| Signals Energized Using PPMX Contacts (20 AWG) | 3A | 3A | |
| Voltage Rating (AC/DC) | UL 1977 | 600V | 600V |
| Dielectric Withstanding Voltage (Volts AC) | 2,200 | 2,200 | |
| Average Mated Contact Resistance (Milliohms) | Power (1/4 in. of 4 AWG) | 0.16m | 0.16m |
| Ground (1/4 in. of 6 AWG) | 0.22m | N/A | |
| Auxiliary (14 AWG) | 2.50m | 2.50m | |
| UL Hot Plug Current Rating (Amperes) | 250 cycles at 120V DC | 50A (4 AWG) | 50A (4 AWG) |
| Short Time Current Test | 1530 Amps (6 AWG / 16mm) Wire, 6 Seconds | N/A | N/A |
| Operating Temperature | -20C to 105C / -4 F to 221F | -20C to 105C / -4 F to 221F | |
| Mating Cycles (No Load by Plating) | 5,000 | 5,000 | |
| Maximum Power Contacts Wire Size | AWG / mm | 10 to 4 / 2.5 to 25.0 | 10 to 4 / 2.5 to 25.0 |
| Maximum Auxiliary Contacts Wire Size | AWG / mm | 14 to 24 / 1.5 to 0.50 | 24 to 20 / 0.50 to 0.75 |
| Maximum Ground Contacts Wire Size | AWG / mm | 12 to 6 / 2.5 to 16 | 12 to 6 / 2.5 to 16 |
| Maximum Wire Insulation Diameter | Power/Ground | 0.44 in. (11.18 mm) | 0.44 in. (11.18 mm) |
| Auxiliary | 0.44 in. (11.18 mm) | 0.44 in. (11.18 mm) | |
| Average Mating / Unmating Force | 4 AWG (25 mm) Wire | 6.5 Lbs (2.95 Kg) | 6.5 Lbs (2.95 Kg) |
| 6 AWG Ground Wire | 12 Lbs (5.44 Kg) | N/A | |
| Pull Out Force with Cable Clamp | Power/Signal | 60 lb. [267N] | 60 lb. [267N] |
| Ground Only | 60 lb. [267N] | 60 lb. [267N] | |
| Push Out Retention Force | Auxiliary | 35 lb. [156N] | 35 lb. [156N] |
| Drop Test | Per IEC 60512-5 | Yes | Yes |
| IP Rating | Per UL50E4 | IP68 | IP68 |
| Maximum Power Rating | 600 Volts / 140A | 600 Volts / 140A |
2411081329_Anderson-Power-115233P13_C21338068.pdf