High Reliability Anderson Power 320-22 Battery Connector with Operating Temperature Range to 105C
Product Overview
The Anderson A Series Battery Connectors are expertly designed for ease of use and feature an innovative contact carrier for simplified assembly. Available in standard 80, 160, and 320 sizes, these connectors offer robust design and superior performance with materials chosen for years of reliability in adverse industrial environments. They are ideal for a wide range of industrial applications, including Material Handling, Battery Charging, Utility Vehicles, Motive Power, and Sweepers/Scrubbers. The A Series connectors meet or exceed EN1175:2020 standards and are cURus rated.
Product Attributes
- Brand: Anderson
- Compliance: RoHS Compliant, Meets or Exceeds EN1175:2020, cURus Rated
- Resistance: Acid & Impact Resistant
- Materials: Sturdy Advanced Polymer Housings (PA6, glass filled), Silver Plated Copper Contacts (Copper alloy silver plate), Hardware (Steel, zinc chromate plate)
- Contact Plating: Power (min. Silver Plating - 6 microns), Auxiliary (min. Silver Plating - 6 microns)
- Operating Temperature: -25 to 105C
Technical Specifications
| Specification | A80 | A160 | A320 |
|---|---|---|---|
| Current Ratings (Amperes) | Up to 400A (See table below) | Up to 400A (See table below) | Up to 400A (See table below) |
| Voltage Keying Options | Dry-Cell, Wet-Cell, Universal | Dry-Cell, Wet-Cell, Universal | Dry-Cell, Wet-Cell, Universal |
| Voltage Ratings (DC) | 24/36/48/72/80/96V | 24/36/48/72/80/96V | 24/36/48/72/80/96V |
| Voltage Rating (cUR/UR) | 600V | 600V | 600V |
| Voltage Rating (EN1175 AC/DC) | 150V | 150V | 150V |
| DWV (AC) | 2200 | 2200 | 2200 |
| Mechanical Life Cycle (Mating Cycles) | >5000 (No Load), 5 (Under Load at 400A, Hot Plug at 96V) | >5000 (No Load), 5 (Under Load at 400A, Hot Plug at 96V) | >5000 (No Load) |
| Avg. Mating Force (N / lb) | 68 / 15.3 | 170 / 38.2 | 71 / 16.0 |
| Contact Retention (N min / lb min) | 134 / 30 | 445 / 100 | 445 / 100 |
| Degree of Protection | IP23 | IP23 | IP23 |
| Flammability | UL94 HB, Horizontal Burn | UL94 HB, Horizontal Burn | UL94 HB, Horizontal Burn |
| Average Initial Contact Resistance - Power () | 65 | 55 | 30 |
| Average Initial Contact Resistance - Aux. () | 1100 | 920 | 1000 |
Electrical Current Ratings (Amperes)
| Wire Size (mm) | Wire Size (AWG) | A80 (EN1175) | A80 (CNR) | A80 (USR) | A160 (EN1175) | A160 (CNR) | A160 (USR) | A320 (EN1175) | A320 (CNR) | A320 (USR) |
|---|---|---|---|---|---|---|---|---|---|---|
| 10 | 8 | N/A | 70 | 90 | N/A | N/A | N/A | N/A | N/A | N/A |
| 16 | 6 | 80 | 120 | 120 | 80 | 90 | 120 | N/A | N/A | N/A |
| 25 | 4 | 120 | 140 | 140 | 120 | 120 | 160 | N/A | N/A | N/A |
| 35 | 2 | 160 | 160 | 160 | 160 | 140 | 180 | N/A | N/A | N/A |
| 50 | 1/0 | N/A | N/A | N/A | 250 | 160 | 220 | 250 | 165 | 220 |
| 70 | 2/0 to 3/0 | N/A | N/A | N/A | N/A | N/A | N/A | 200 | 260 | 260 |
| 95 | 3/0 to 4/0 | N/A | N/A | N/A | N/A | N/A | N/A | 400 | 245 | 425 |
| 120 | 4/0 | N/A | N/A | N/A | N/A | N/A | N/A | 260 | 450 | 450 |
Note: CNR allows for max temp rise = 30C (above 25C ambient). USR allows for total temp (based on min. 25C ambient) = 105C. EN1175:2020 allows for max temp rise = 65C (above 25C ambient). All auxiliary contacts rated to a min 20 amps when tested to EN1175:2020.
2411121053_Anderson-Power-320-22_C7178169.pdf