Multiway quick mating connectors with strain relief hoods and positive polarization featuring EATON SMS9H1
SMS Series Quick Mating Connectors
The versatile and easy to use SMS Quick Mating panel and cable connectors offer a highly cost-effective system approach for interconnection solutions. These connectors provide rapid assembly/installation without additional mounting hardware. Panel receptacle connectors snap and lock into panel cut-outs, while cable plugs connect and disconnect with positive retention locks via a push-to-mate and press-and-release-to-unmate mechanism. Cable plug connectors feature pin-protection skirts, positive polarization, and optional integrated strain relief hoods. Cable receptacle connectors are available for cable-to-cable solutions. These multi-way connectors accept TRIM TRIO size 16 (1.6mm) diameter contacts and are available in 10 contact arrangements from 2 to 36 positions. Typical applications include machinery, railway (closed from electrical operating areas, interior & cabin, signaling), and robotics.
Product Attributes
- Brand: SOURIAU
- Registered Trademark: SOURIAU
- Origin: Not specified
- Material: Connector: Polyamide 6.6
- Flammability Rating: Black versions: UL94 V2; White versions: UL 94 V0 & HL3/R22 - HL3/R23 following EN 45 545-2
- Certifications: UL recognized File Nr.: E238675; CSA certified File Nr.: LR44961-21
Technical Specifications
| Part Number | Nbr. of Contact* | Body Variation | Flammability | Wire Acceptance (max. mm) | Environmental Operating Temperature (C) | Insulation Resistance (M min.) | Test Potential (VAC) | Durability (matings) | Sealing Performances | Electrical Performances (UL/CSA) | Dimensions (mm) |
| SMS2R1/SMS2R3 | 2 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 11.0, B: 5.8, C max.: 15.2, J: 11.4, K: 11.6 |
| SMS3R1/SMS3R3 | 3 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 16.2, B: 16.5, C max.: 17.8 |
| SMS4R1/SMS4R3 | 4 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 21.1, B: 21.7, C max.: 23.7 |
| SMS6R1/SMS6R3 | 6 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 16.2, B: 10.9, C max.: 20.3, J: 16.5, K: 16.7 |
| SMS9R1/SMS9R3 | 9 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 16.0, B: 25.4, C max.: 26.7, J: 21.6 |
| SMS12R1/SMS12R3 | 12 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 21.1, B: 30.5, C max.: 31.8, J: 26.7 |
| SMS15R1/SMS15R3 | 15 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 26.2, B: 35.6, C max.: 36.9 |
| SMS18R1/SMS18R3 | 18 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 31.2, B: 40.6, C max.: 41.8 |
| SMS24R1/SMS24R3 | 24 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 21.2, B: 21.7, C max.: 25.0, J: 30.5 |
| SMS36R1/SMS36R3 | 36 | Panel mount receptacle | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 46.6, B: 21.1, C max.: 33.0, J: 26.7 |
| SMS2P1/SMS2PD3 | 2 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 15.0, C max.: 17.8, J: 13.2 |
| SMS3P1/SMS3PD3 | 3 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 18.6, C max.: 18.6 |
| SMS4P1/SMS4PD3 | 4 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 23.7, C max.: 23.7 |
| SMS6P1/SMS6PD3 | 6 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 18.6, C max.: 22.9, J: 21.5 |
| SMS9P1/SMS9PD3 | 9 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 27.9, C max.: 27.9 |
| SMS12P1/SMS12PD3 | 12 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 33.0, C max.: 33.0 |
| SMS15P1/SMS15PD3 | 15 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 38.1, C max.: 38.1 |
| SMS18P1/SMS18PD3 | 18 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 43.2, C max.: 43.2 |
| SMS24P1/SMS24PD3 | 24 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 23.7, C max.: 25.0 |
| SMS36P1/SMS36PD3 | 36 | Cable plug without strain relief hood | UL94 V2 / UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 49.1, C max.: 33.0 |
| SMS2RD3 | 2 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 9.9, C: 8.4, D: 11.1, E: 14.1 |
| SMS3RD3 | 3 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 16.2, C: 18.6 |
| SMS4RD3 | 4 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 21.2, C: 23.7 |
| SMS6RD3 | 6 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 15.0, C: 16.2, D: 18.6, E: 13.4 |
| SMS9RD3 | 9 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 20.0, C: 25.1, D: 18.5 |
| SMS12RD3 | 12 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 25.1, C: 30.2, D: 23.6 |
| SMS15RD3 | 15 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 30.2, C: 35.3, D: 28.7 |
| SMS18RD3 | 18 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 35.3, C: 40.4, D: 33.8 |
| SMS24RD3 | 24 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 21.2, C: 23.7, D: 46.6 |
| SMS36RD3 | 36 | Cable receptacle without strain relief hood | UL 94 V0 | 4.19 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | B max.: 25.1, C: 31.7, D: 49.1 |
| SMS2RDH1/SMS2RDH3 | 2 | Cable receptacle with integrated strain relief hood | UL94 V2 / UL 94 V0 | 0.5-8.4 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 31.6, B: 9.9, C: 11.1, D: 0.5, H: 49.2 |
| SMS3RDH1/SMS3RDH3 | 3 | Cable receptacle with integrated strain relief hood | UL94 V2 / UL 94 V0 | 0.8-7.3 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 35.1, B: 16.2, C: 69.0, D: 0.8, H: 74.4 |
| SMS4RDH1/SMS4RDH3 | 4 | Cable receptacle with integrated strain relief hood | UL94 V2 / UL 94 V0 | 1.5-10 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 38.2, B: 21.2, C: 74.4, D: 1.5, H: 79.6 |
| SMS6RDH1/SMS6RDH3 | 6 | Cable receptacle with integrated strain relief hood | UL94 V2 / UL 94 V0 | 1.7-9.2 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 34.6, B: 15.0, C: 16.2, D: 1.7, H: 50.9 |
| SMS9RDH1/SMS9RDH3 | 9 | Cable receptacle with integrated strain relief hood | UL94 V2 / UL 94 V0 | 3.9-14.2 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 35.8, B: 20.0, C: 75.3, D: 3.9, H: 52.2 |
| SMS12RDH1/SMS12RDH3 | 12 | Cable receptacle with integrated strain relief hood | UL94 V2 / UL 94 V0 | 4.0-15.0 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 38.1, B: 25.1, C: 72.0, D: 4.0, H: 52.7 |
| SMS15RDH1/SMS15RDH3 | 15 | Cable receptacle with integrated strain relief hood | UL94 V2 / UL 94 V0 | 5.0-16.2 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 35.9, B: 30.2, C: 81.3, D: 5.0, H: 55.2 |
| SMS18RDH1/SMS18RDH3 | 18 | Cable receptacle with integrated strain relief hood | UL94 V2 / UL 94 V0 | 5.0-16.2 | -55 to +105 | 5000 | 2000 | 500 | IP40 | 250V - 10A / 250V - 15A | A: 38.1, B: 35.3, C: 81.3, D: 5.0, H: 55.2 |
2411061630_EATON-SMS9H1_C22351627.pdf
quick mating connectors EATON SMS6H1 designed for snap lock panel cut outs and positive polarization
High density quick mating connector system EATON SMS2H1 designed for rapid assembly and installation
Quick Mating Panel and Cable Connectors Featuring EATON SMS24H1 with Integrated Strain Relief Hoods
Durable versatile panel and cable connectors featuring EATON SMS3H1 for interconnection solutions
Flame retardant EATON SMSPKE3 connector providing 36 contacts and tested durability for railway indoor
| Image | Part # | Description | |
|---|---|---|---|
|
|
quick mating connectors EATON SMS6H1 designed for snap lock panel cut outs and positive polarization |
Rectangular Connector Accessories RoHS
|
|
|
|
High density quick mating connector system EATON SMS2H1 designed for rapid assembly and installation |
Rectangular Connector Accessories RoHS
|
|
|
|
Quick Mating Panel and Cable Connectors Featuring EATON SMS24H1 with Integrated Strain Relief Hoods |
Rectangular Connector Accessories RoHS
|
|
|
|
Durable versatile panel and cable connectors featuring EATON SMS3H1 for interconnection solutions |
Rectangular Connector Accessories RoHS
|
|
|
|
Flame retardant EATON SMSPKE3 connector providing 36 contacts and tested durability for railway indoor |
Rectangular Connector Accessories RoHS
|