Compact and JST 02CR-6H-P insulation displacement connector for UL1007 wire applications in electronic devices
Product Overview
The CR 2.0mm insulation displacement connector offers a low profile with a mounting height as low as 6.9mm and a thickness of 4.8mm (for top entry type). It is designed for the interconnection of UL1007 electric wires in a variety of electrical and electronic equipment such as VCRs and video cameras. Key features include automatic harness production capability, a folded beam double-leaf contact construction for enhanced strength and resistance to misinsertion, a twin U-slot insulation displacement section for high reliability, and a strain relief feature to protect the connection from external stress. The shrouded headers are interchangeable with KR, KRD insulation displacement, and PH crimp style connectors.
Product Attributes
- Brand: JST
- Certifications: UL Recognized E60389, CSA Certified LR20812
- Material: Post: Phosphor bronze, tin-plated (reflow treatment); Housing: Glass-filled PA 66, UL94V-0
- Color: Gray (Housing)
- RoHS Compliance: Yes
Technical Specifications
| Model No. | Circuits | Dimensions (mm) A | Dimensions (mm) B | Q'ty / box | Current Rating | Voltage Rating | Temperature Range | Contact Resistance (Initial) | Contact Resistance (After Env. Testing) | Insulation Resistance | Withstanding Voltage | Applicable Wire | Applicable PC Board Thickness |
| 02CR-6H-P | 2 | 2.0 | 6.0 | 2,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 03CR-6H-P | 3 | 4.0 | 8.0 | 2,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 04CR-6H-P | 4 | 6.0 | 10.0 | 2,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 05CR-6H-P | 5 | 8.0 | 12.0 | 2,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 06CR-6H-P | 6 | 10.0 | 14.0 | 2,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 07CR-6H-P | 7 | 12.0 | 16.0 | 2,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 08CR-6H-P | 8 | 14.0 | 18.0 | 1,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 09CR-6H-P | 9 | 16.0 | 20.0 | 1,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 10CR-6H-P | 10 | 18.0 | 22.0 | 1,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 11CR-6H-P | 11 | 20.0 | 24.0 | 1,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
| 12CR-6H-P | 12 | 22.0 | 26.0 | 1,000 | 1.0A AC, DC | 100V AC, DC | -25C to +85C | 10m max. | 20m max. | 1,000M min. | 800V AC/minute | UL1007 AWG #26 (7 strands, tin-coated), Insulation O.D./1.3mm max. | 0.8 to 1.6mm |
2411220211_JST-02CR-6H-P_C265029.pdf