Durable OMRON XC5C-6422 DIN twin contact connectors meeting UL CSA standards for industrial applications
Product Overview
The XC5 DIN Twin-contact Connectors offer a wide variety of DIN connectors that conform to UL/CSA standards. They fully preserve the characteristics of normal DIN connectors while increasing the number of terminals available, providing a wide product range to fit almost any application. These connectors meet world market needs with products ranging from one-piece connectors (card edge) to two-piece connectors, utilizing a twin-contact system for high reliability and lower insertion force achieved through FEM analysis techniques. Refer to the "Standards certification / conformity list" for information on conformity to certification standards.
Product Attributes
- Brand: OMRON
- Certifications: UL/CSA Standards, RoHS Compliant
- Materials: Housings: Fiber-glass reinforced PBT resin (UL94 V-0)/gray; Contacts: Mating end - Brass/nickel base, 0.4-m gold plating; Terminal - Brass/nickel base, 2.0-m tin plating; Wrap terminal contacts - Phosphor bronze.
- Color: Gray (Housings)
Technical Specifications
| Model Series | Type | No. of Contacts | Rated Current | Rated Voltage | Contact Resistance | Insulation Resistance | Dielectric Strength | Total Insertion Force | Removal Force | Insertion Durability | Ambient Operating Temperature | Dimensions (A x B x C x D x E x F) | Coding Key Positions |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XC5A | Double-row Plugs, DIN B-type (Standard) | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C | 37.9 x 32.1 x 22.86 x 33.02 x 28.1 x 29.3 mm | 3, 8 |
| XC5A | Double-row Plugs, DIN B-type (Standard) | 32 | 53.2 x 47.4 x 38.10 x 48.26 x 43.3 x 44.6 mm | 5, 12 | |||||||||
| XC5A | Double-row Plugs, DIN B-type (Standard) | 44* | 68.4 x 62.6 x 53.34 x 63.50 x 58.5 x 59.8 mm | 4, 9, 14, 19 | |||||||||
| XC5A | Double-row Plugs, DIN B-type (Standard) | 50* | 76.0 x 70.2 x 60.96 x 71.12 x 66.2 x 67.4 mm | 5, 10, 16, 21 | |||||||||
| XC5A | Double-row Plugs, DIN B-type (Standard) | 64 | 93.8 x 88.0 x 78.74 x 88.90 x 83.9 x 85.2 mm | 6, 13, 20, 27 | |||||||||
| XC5A | Double-row Plugs, DIN B-type (Standard) | 100* | 139.5 x 133.7 x 124.46 x 134.62 x 129.7 x 130.9 mm | 10, 20, 31, 41 | |||||||||
| XC5B | Double-row Sockets, DIN B-type (Standard) | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C | 38.9 x 29.1 x 22.86 x 34.12 x 27.1 mm | 3, 8 |
| XC5B | Double-row Sockets, DIN B-type (Standard) | 32 | 54.2 x 44.4 x 38.10 x 49.36 x 42.3 mm | 5, 12 | |||||||||
| XC5B | Double-row Sockets, DIN B-type (Standard) | 44* | 69.4 x 59.6 x 53.34 x 64.60 x 57.5 mm | 4, 9, 14, 19 | |||||||||
| XC5B | Double-row Sockets, DIN B-type (Standard) | 50* | 77.0 x 67.2 x 60.96 x 72.22 x 65.2 mm | 5, 10, 16, 21 | |||||||||
| XC5B | Double-row Sockets, DIN B-type (Standard) | 64 | 94.8 x 85.0 x 78.74 x 90.00 x 82.9 mm | 6, 13, 20, 27 | |||||||||
| XC5B | Double-row Sockets, DIN B-type (Standard) | 100* | 140.5 x 130.7 x 124.46 x 135.72 x 128.7 mm | 10, 20, 31, 41 | |||||||||
| XC5E | Double-row Plugs, DIN Q-type (Reverse) | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C | 38.9 x 32.1 x 22.86 x 34.12 x 28.1 x 29.3 mm | 3, 8 |
| XC5E | Double-row Plugs, DIN Q-type (Reverse) | 32 | 54.2 x 47.4 x 38.10 x 49.36 x 43.3 x 44.6 mm | 5, 12 | |||||||||
| XC5E | Double-row Plugs, DIN Q-type (Reverse) | 44* | 69.4 x 62.6 x 53.34 x 64.60 x 58.5 x 59.8 mm | 4, 9, 14, 19 | |||||||||
| XC5E | Double-row Plugs, DIN Q-type (Reverse) | 50* | 77.0 x 70.2 x 60.96 x 72.22 x 66.2 x 67.4 mm | 5, 10, 16, 21 | |||||||||
| XC5E | Double-row Plugs, DIN Q-type (Reverse) | 64 | 94.8 x 88.0 x 78.74 x 90.00 x 83.9 x 85.2 mm | 6, 13, 20, 27 | |||||||||
| XC5E | Double-row Plugs, DIN Q-type (Reverse) | 100* | 140.5 x 133.7 x 124.46 x 135.72 x 129.7 x 130.9 mm | 10, 20, 31, 41 | |||||||||
| XC5F | Double-row Sockets, DIN Q-type (Reverse) | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C | 37.9 x 29.1 x 22.86 x 33.02 x 27.1 mm | 3, 8 |
| XC5F | Double-row Sockets, DIN Q-type (Reverse) | 32 | 53.2 x 44.4 x 38.10 x 48.26 x 42.3 mm | 5, 12 | |||||||||
| XC5F | Double-row Sockets, DIN Q-type (Reverse) | 44* | 68.4 x 59.6 x 53.34 x 63.50 x 57.5 mm | 4, 9, 14, 19 | |||||||||
| XC5F | Double-row Sockets, DIN Q-type (Reverse) | 50* | 76.0 x 67.2 x 60.96 x 71.12 x 65.2 mm | 5, 10, 16, 21 | |||||||||
| XC5F | Double-row Sockets, DIN Q-type (Reverse) | 64 | 93.8 x 85.0 x 78.74 x 88.90 x 82.9 mm | 6, 13, 20, 27 | |||||||||
| XC5F | Double-row Sockets, DIN Q-type (Reverse) | 100* | 139.5 x 130.7 x 124.46 x 134.62 x 128.7 mm | 10, 20, 31, 41 | |||||||||
| XC5C | Triple-row Plugs, DIN C-type (Standard) | 32* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C | 53.2 x 47.4 x 38.10 x 48.26 x 43.3 x 44.6 mm | 5, 12 |
| XC5C | Triple-row Plugs, DIN C-type (Standard) | 48 | 53.2 x 47.4 x 38.10 x 48.26 x 43.3 x 44.6 mm | 5, 12 | |||||||||
| XC5C | Triple-row Plugs, DIN C-type (Standard) | 64* | 93.8 x 88.0 x 78.74 x 88.90 x 83.9 x 85.2 mm | 6, 13, 20, 27 | |||||||||
| XC5C | Triple-row Plugs, DIN C-type (Standard) | 96 | 93.8 x 88.0 x 78.74 x 88.90 x 83.9 x 85.2 mm | 6, 13, 20, 27 | |||||||||
| XC5D | Triple-row Sockets, DIN C-type (Standard) | 32* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C | 54.2 x 44.4 x 38.10 x 49.36 x 42.3 mm | 5, 12 |
| XC5D | Triple-row Sockets, DIN C-type (Standard) | 48 | 54.2 x 44.4 x 38.10 x 49.36 x 42.3 mm | 5, 12 | |||||||||
| XC5D | Triple-row Sockets, DIN C-type (Standard) | 64* | 94.8 x 85.0 x 78.74 x 90.00 x 82.9 mm | 6, 13, 20, 27 | |||||||||
| XC5D | Triple-row Sockets, DIN C-type (Standard) | 96 | 94.8 x 85.0 x 78.74 x 90.00 x 82.9 mm | 6, 13, 20, 27 | |||||||||
| XC5G | Triple-row Plugs, DIN R-type (Reverse) | 48 | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C | 54.2 x 47.4 x 38.10 x 49.36 x 43.3 x 44.6 mm | 5, 12 |
| XC5G | Triple-row Plugs, DIN R-type (Reverse) | 64* | 94.8 x 88.0 x 78.74 x 90.00 x 83.9 x 85.2 mm | 6, 13, 20, 27 | |||||||||
| XC5G | Triple-row Plugs, DIN R-type (Reverse) | 96 | 94.8 x 88.0 x 78.74 x 90.00 x 83.9 x 85.2 mm | 6, 13, 20, 27 | |||||||||
| XC5H | Triple-row Sockets, DIN R-type (Reverse) | 48 | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C | 53.2 x 44.4 x 38.10 x 48.26 x 42.3 mm | 5, 12 |
| XC5H | Triple-row Sockets, DIN R-type (Reverse) | 64* | 93.8 x 85.0 x 78.74 x 88.90 x 82.9 mm | 6, 13, 20, 27 | |||||||||
| XC5H | Triple-row Sockets, DIN R-type (Reverse) | 96 | 93.8 x 85.0 x 78.74 x 88.90 x 82.9 mm | 6, 13, 20, 27 |
Tools and Accessories (Sold Separately)
Dust Cover:
XC5T-962 (For DIN41612 C- or R-type Triple-row Plugs with 64 or 96 contacts)
XC5T-963 (For DIN41612 C- or R-type Triple-row Sockets with 64 or 96 contacts)
Note: This is a dust-proof cover that is not used at the moment and not the one that protects against flux in automatic soldering.
Coding Cutter:
XY2D-0001
1. Cut the Coding Key(s) in the slot in the plug housing wall with the special cutting tool (XY2D-0001). Note: Coding Cutters may not work with some DIN-style connector combinations. In that case...
2501101205_OMRON-XC5C-6422_C2896778.pdf