Durable Fiber Glass Reinforced OMRON XC5F 5022 2 Twin Contact Connectors for Industrial Applications
Product Overview
The XC5 DIN Twin-contact Connectors offer a wide variety of connector options that conform to UL/CSA standards. These connectors preserve the characteristics of normal DIN connectors while increasing terminal availability. They are designed to fit almost any application, meeting world market needs with a range from one-piece to two-piece connectors. The twin-contact system ensures high reliability, and FEM analysis techniques contribute to lower insertion force.
Product Attributes
- Brand: OMRON
- Certifications: UL/CSA Standards, RoHS Compliant
- Materials: Fiber-glass reinforced PBT resin (UL94 V-0) for housings, Brass/nickel base and Phosphor bronze/nickel base for contacts.
- Color: Gray (housings)
Technical Specifications
| Series | Type | No. of Contacts | Rated Current | Rated Voltage | Contact Resistance | Insulation Resistance | Dielectric Strength | Total Insertion Force | Removal Force | Insertion Durability | Ambient Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
| XC5A (Double-row Plugs, DIN B-type) | Right-angle DIP terminals | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5A | Right-angle DIP terminals | 32 | |||||||||
| XC5A | Right-angle DIP terminals | 44* | |||||||||
| XC5A | Right-angle DIP terminals | 50* | |||||||||
| XC5A | Right-angle DIP terminals | 64 | |||||||||
| XC5A | Right-angle DIP terminals | 100* | |||||||||
| XC5B (Double-row Sockets, DIN B-type) | Straight DIP terminals | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5B | Straight DIP terminals | 32 | |||||||||
| XC5B | Straight DIP terminals | 44* | |||||||||
| XC5B | Straight DIP terminals | 50* | |||||||||
| XC5B | Straight DIP terminals | 64 | |||||||||
| XC5B | Straight DIP terminals | 100* | |||||||||
| XC5B | Straight wrap terminals | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5B | Straight wrap terminals | 32 | |||||||||
| XC5B | Straight wrap terminals | 44* | |||||||||
| XC5B | Straight wrap terminals | 50* | |||||||||
| XC5B | Straight wrap terminals | 64 | |||||||||
| XC5B | Straight wrap terminals | 100* | |||||||||
| XC5E (Double-row Plugs, DIN Q-type) | Straight DIP terminals | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5E | Straight DIP terminals | 32 | |||||||||
| XC5E | Straight DIP terminals | 44* | |||||||||
| XC5E | Straight DIP terminals | 50* | |||||||||
| XC5E | Straight DIP terminals | 64 | |||||||||
| XC5E | Straight DIP terminals | 100* | |||||||||
| XC5E | Straight wrap terminals | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5E | Straight wrap terminals | 32 | |||||||||
| XC5E | Straight wrap terminals | 44* | |||||||||
| XC5E | Straight wrap terminals | 50* | |||||||||
| XC5E | Straight wrap terminals | 64 | |||||||||
| XC5E | Straight wrap terminals | 100* | |||||||||
| XC5F (Double-row Sockets, DIN Q-type) | Right-angle DIP terminals | 20* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5F | Right-angle DIP terminals | 32 | |||||||||
| XC5F | Right-angle DIP terminals | 44* | |||||||||
| XC5F | Right-angle DIP terminals | 50* | |||||||||
| XC5F | Right-angle DIP terminals | 64 | |||||||||
| XC5F | Right-angle DIP terminals | 100* | |||||||||
| XC5C (Triple-row Plugs, DIN C-type) | Right-angle DIP terminals | 32* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5C | Right-angle DIP terminals | 48 | |||||||||
| XC5C | Right-angle DIP terminals | 64* | |||||||||
| XC5C | Right-angle DIP terminals | 96 | |||||||||
| XC5D (Triple-row Sockets, DIN C-type) | Straight DIP terminals | 32* | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5D | Straight DIP terminals | 48 | |||||||||
| XC5D | Straight DIP terminals | 64* | |||||||||
| XC5D | Straight DIP terminals | 96 | |||||||||
| XC5D | Straight wrap terminals | 48 | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5D | Straight wrap terminals | 64* | |||||||||
| XC5D | Straight wrap terminals | 96 | |||||||||
| XC5G (Triple-row Plugs, DIN R-type) | Straight DIP terminals | 48 | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5G | Straight DIP terminals | 64* | |||||||||
| XC5G | Straight DIP terminals | 96 | |||||||||
| XC5G | Straight wrap terminals | 48 | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5G | Straight wrap terminals | 64* | |||||||||
| XC5G | Straight wrap terminals | 96 | |||||||||
| XC5H (Triple-row Sockets, DIN R-type) | Right-angle DIP terminals | 48 | 2 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 106 M min. (at 100 VDC) | 1,000 VAC for 1 min (leakage current: 1 mA max.) | 0.59 N max. per contact | 0.15 N min. (with test gauge, t = 0.56 mm) | 200 times | 55 to 125C |
| XC5H | Right-angle DIP terminals | 64* | |||||||||
| XC5H | Right-angle DIP terminals | 96 |
Tools and Accessories
Dust Cover:
XC5T-962 (For DIN41612 C- or R-type Triple-row Plugs with 64 or 96 contacts)
XC5T-963 (For DIN41612 C- or R-type Triple-row Sockets with 64 or 96 contacts)
Note: This is a dust-proof cover, not for flux protection during automatic soldering.
Coding Cutter:
XY2D-0001
Used to cut Coding Keys in the plug housing slot. May not be compatible with all DIN-style connector combinations.
2411041600_OMRON-XC5F-5022-2_C6030350.pdf