Durable Anderson Power 269G2 Multi Axial Rotational Connector with Genderless Design and 8 Powerpole Contacts
Product Overview
The MARC Multi Axial Rotational Connector (MARC) is a robust blindmate connector featuring 8 Powerpole contacts within a blindmate housing. Designed for straight-on or blindmating from two rotating axes with .100 of error correction, it utilizes industry-leading flat wiping contacts in a two-row, horizontally oriented configuration. The MARC is rated to 29 amps per circuit and offers flexibility with configurations of 8 standard length contacts or 6 standard length and 2 pre-mate, multi-purpose contacts for ground, power, or signal. Its durable construction is UL listed and rated for up to 10,000 mating cycles, with a chemically resistant PBT plastic dielectric. The genderless design simplifies assembly and reduces inventory. Typical applications benefit from its rotational blindmate error correction and sequential mating capabilities.
Product Attributes
- Brand: Anderson Power Products (APP)
- Contact Type: Powerpole
- Housing Material: Chemically resistant PBT plastic
- Flammability Rating: UL94 V-0
- Certifications: UL listed
- Genderless Design
- Contact Technology: Flat wiping contacts
Technical Specifications
| Feature | Specification |
|---|---|
| Model Name | MARC Multi Axial Rotational Connector |
| Contact Capacity | 8 Powerpole contacts |
| Mating Type | Blindmate (2 rotating axes or straight on) |
| Error Correction | .100 rotational blindmate |
| Contact Configuration Options | 8 standard contacts OR 6 standard + 2 pre-mate contacts |
| Current Rating per Circuit | 29 amps |
| Mating Cycles | Up to 10,000 |
| Dielectric Material | PBT plastic |
| Voltage Rating | 600V AC/DC per UL1977; 150V DC per EN1175-1 |
| Contact Barrel Wire Size (AWG) | 10 to 20 |
| Contact Barrel Wire Size (mm) | 4 to 0.5 |
| Maximum Wire Insulation Diameter | 0.175 inches (4.45 mm) |
| Contact Retention Force (lbf) | 25 (111 N) |
| Average Disconnect Force (lbf) | 18 (80 N) |
| Operating Temperature Range | -40 to 125C (-40 to 257F) |
Ordering Information - Housings
| Description | Part Number | Minimum Quantity |
|---|---|---|
| Housing with springs | 602G00 | 25 |
| Housing with float mount kit | 602G01 | 25 |
| Housing with fixed mount kit | 602G02 | 25 |
Ordering Information - Contacts
PP15-45 Tin Plated Power Contacts
| Contact Type | AWG | mm | Mating Force | Loose Piece Part Number | Reeled Part Number | Minimum Quantity (Loose Piece) | Minimum Quantity (Reeled) |
|---|---|---|---|---|---|---|---|
| Open | 14 to 10 | 2.1 to 5.3 | K* High | 269G3-LPBK | 269G3 | 200 | 5,000 |
| Open | 14 to 10 | 2.1 to 5.3 | K* Low | 261G2-LPBK | 261G2 | 200 | 5,000 |
| Open | 14 to 10 | 2.1 to 6.0 | SF* High | 201G1H-LPBK | 201G1H | 200 | 5,000 |
| Open | 14 to 10 | 2.1 to 6.0 | SF* Low | 200G1L-LPBK | 200G1L | 200 | 5,000 |
| Open | 16 to 12 | 1.3 to 3.3 | High | 269G1-LPBK | 269G1 | 200 | 5,000 |
| Open | 16 to 12 | 1.3 to 3.3 | Low | 261G1-LPBK | 261G1 | 200 | 5,000 |
| Open | 20 to 16 | 0.52 to 1.3 | High | 269G2-LPBK | 269G2 | 200 | 5,000 |
| Open | 20 to 16 | 0.52 to 1.3 | Low | 262G1-LPBK | 262G1 | 200 | 5,000 |
| Open | 20 to 16 | 0.52 to 1.5 | SF* Low | 200G2L-LPBK | 200G2L | 200 | 5,000 |
K* - For #10 AWG class K stranded wire or smaller. For larger wires use superflex contacts. SF*- Indicates wires with high stranding such as Super Flex.
45A Premate Ground Wire Contacts (Tin or Silver Plated)
| Contact Type | AWG | mm | Mating Force | Loose Piece Part Number | Reeled Part Number | Minimum Quantity (Loose Piece) | Minimum Quantity (Reeled) |
|---|---|---|---|---|---|---|---|
| Open, Tin | 14 to 10 | 2.1 to 6.0 | Low | 1830G1-LPBK | 1830G1 | 200 | 5,000 |
| Open, Silver | 14 to 10 | 2.1 to 6.0 | Low | 1830G2-LPBK | 1830G2 | 200 | 5,000 |
Tin contacts rated for up to 1,500 mating cycles. Silver contacts rated up to 10,000 mating cycles.
PP15-45 Silver Plated Power Contacts
| Contact Type | AWG | mm | Mating Force | Loose Piece Part Number | Reeled Part Number | Minimum Quantity (Loose Piece) | Minimum Quantity (Reeled) |
|---|---|---|---|---|---|---|---|
| Open | 14 to 10 | 2.1 to 5.3 | Low | 261G3-LPBK | 261G3 | 200 | 5,000 |
| Open | 14 to 10 | 2.1 to 6.0 | SF* High | - | 201G3H | 200 | 5,000 |
| Open | 14 to 10 | 2.1 to 6.0 | SF* Low | 200G3L-LPBK | 200G3L | 200 | 5,000 |
| Open | 16 to 12 | 1.3 to 3.3 | Low | 261G4-LPBK | 261G4 | 200 | 5,000 |
| Open | 20 to 16 | 0.52 to 1.3 | Low | 262G2-LPBK | 262G2 | 200 | 5,000 |
| Open | 20 to 16 | 0.52 to 1.5 | SF* Low | - | 200G4L | 200 | 5,000 |
| Closed | 16 to 12 | 1.3 to 3.3 | Low | 1331-BK | 1331 | 200 | 5,000 |
| Closed | 20 to 16 | 0.52 to 1.3 | Low | 1332-BK | 1332 | 200 | 5,000 |
Silver plated contacts rated for up to 10,000 mating cycles.
Ordering Information - Accessories
| Description | Part Number | Minimum Quantity |
|---|---|---|
| Float Mount Kit | 110G69 | 25 |
| Fixed Mount Kit | 103G40 | 25 |
Tooling Information
| Wire Size (AWG) | Wire Size (mm) | Contact Type | Hand Tool Die Locator | Number of Crimps | Loose Piece Contact Crimp Tool | Reeled Contact Crimp Tools | ATS Applicator | ATS Press Air Feed Kit* or Pneumatic Bench Tool |
|---|---|---|---|---|---|---|---|---|
| 16 / 20 | 1.3 / 0.52 | Closed | - | - | - | - | 1332 | N/A |
| 12 / 16 | 3.3 / 1.3 | Closed | - | - | - | - | 1331 | N/A |
| 16 / 20 | 1.3 / 0.52 | Open | 262G1-LPBK | 1 | 262G1 | 262G2 | 1385519-1 | Single |
| 12 / 16 | 3.3 / 1.3 | Open | 261G1-LPBK | 1 | 261G1 | 261G4 | 1385520-1 | Single |
| 10 / 14 | 5.3 / 2.1 | Open | 261G2-LPBK | 1 | 261G2 | 261G3 | 1385458-1 | Single |
| 12 / 16 | 3.3 / 1.3 | Open | 269G1-LPBK | 1 | 269G1 | N/A | 1385520-1 | Single |
| 10 / 14 | 5.3 / 2.1 | Open | 269G3-LPBK | 1 | 269G3 | N/A | 1385458-1 | Single |
| 10 / 14 | 6.0 / 2.1 | Open | 200G1L-LPBK | 1 | 200G1L | 200G3L | 1385460-1 | Single |
| 10 / 14 | 6.0 / 2.1 | Open | 201G1H-LPBK | 1 | 201G1H | 201G3H | 1385460-1 | Single |
| 10 / 14 | 6.0 / 2.1 | Premate Ground | 1830G1-LPBK | 1 | 1830G1 | 1830G2 | 1385460-1 | Single |
* All ATS applicators for APP contacts are air feed style and require the press to have an air feed kit installed.
Dimensions
| Mount Type | A (mm) | A (in) | B (mm) | B (in) | C (mm) | C (in) | D (mm) | D (in) |
|---|---|---|---|---|---|---|---|---|
| Float | 12.89 | 0.508 | 25.78 | 1.015 | 22.29 | 0.878 | 44.58 | 1.755 |
| Fixed | 11.11 | 0.438 | 22.23 | 0.875 | 20.51 | 0.808 | 41.02 | 1.615 |
Dimensions are for panel cut-outs.
2411220422_Anderson-Power-269G2_C17207434.pdf