High Durability JINJIA XLR-04P-3 XLR Jack Connector Rated 50V AC 6A with No Surface Scratches or Rust
XLR Jack Specification
This specification applies to XLR jacks used in electronic products. The product is designed for a practical temperature range of -30 to +80 and a humidity range of 85% RH MAX. For preservation, the temperature range is -10 to +40 with 85% RH MAX, and the storage period should not exceed 180 days in an environment free of corrosive gases. The maximum rated voltage and current are 50V AC and 6A, respectively. The appearance should be free of scratches, soil, rust, or discoloration.
Product Attributes
- Brand: Shenzhen jinjiarun Electronic Technology Co., Ltd
- Origin: China
- Document Number: JJR-WI-47
- Issue Date: 2008-09-10
- Version: A1
Technical Specifications
| Item | Property | Test Condition | Performance |
| 2. Rated / | Practical temperature range | -30to +80 | - |
| Humidity range | 85% RH.MAX. | - | |
| 2. Rated / | Preservation temperature range | -10to +40 | - |
| Humidity range | 85% RH.MAX. | - | |
| 2. Rated / | Rated voltage and current(MAX.) | - | 50V AC , 6A |
| 2. Rated / | Appearance | - | No scratchessoilrust or discoloration on the surface. |
| 3. Construction / | Outline And Dimension | - | Should match the attachment drawing. |
| 3. Construction / | Part And Material | - | Should be consistent with the material list specifications. |
| 4. Electrical efficiency / | Withstand Voltage | Withstand AC 1500V (50/60Hz RMS) between two non-contact terminals for 1 minute | No dielectric breakd own shall occur. |
| Insulation Resistance | Apply 500V DC between any contactless terminal and the other terminal, with an insulation gauge and last for 1 minute 5 seconds. | 10000 M Min. | |
| 4. Electrical efficiency / | Contact Resistance | Take a pair of matched terminals and measure the tail end of each terminal (voltage maximum 20mV, current maximum 100mA) | 30 m MAX. |
| 5. Mechanical Performance | Insertion and withdrawal forces | Rate of insertion/withdrawal: 2 mm/s Mating of complete connectors without the effect of any latching or retaining device | Insertion: 35 N max. Withdrawal: 2 N min. |
| Terminal Strength | Every terminal should be capable of withstand a force of 0.5 kgf for 10 seconds. | There is no looseness, damage, etc., but the terminal deformation is acceptable. | |
| 6. Durability / | Life test | Under the condition of no load, rotate and then plug in , rotate and then pull out with a matching plug for 1000 times in total, at a frequency of 5 times per minute. | No obvious change in appearance, destruction. Contact resistance: less than 50 m. |
| Resistance to soldering heat | The jack terminal should be dipped in solder. Temperature of solder: 2603. Dip time: 51 seconds. | After the test, the plastic base should not be deformed and the terminals should not fall off the plastic base. | |
| 7. Solderability / | Solderability | Temperature of solder: 2453C. Time of dip: 30.5 seconds. | Coating of solder area should be more than 95% |
| 8. Environment test / | Cold test | Place the housing for 96 hours at a low temperature of -30 3 C. Then ,place it under standard atmospheric conditions for 1 hour and test. | No obvious change in appearance. Contact resistance:50 mmax Insulation resistance500 M min Withstand voltage:AC 1000V |
| Heat test | The housing should be stored at a temperature of 802for 96 hours. Then it should be subjected to standard atmospheric conditions for 1 hour and test. | - | |
| Humidity test | The housing should be stored at a temperature of 403with relative humidity of 90% ~ 95% for 96 h. Then it should be subjected to standard atmospheric conditions for 1 hour and test. | No obvious change in appearance. Contact resistance:50mmax Insulation resistance500 M minWithstand voltage:AC 1000V | |
| 8. Environment test / | Temperature Cycling | Place the Jack under the conditions shown below and then place it in the stand at room temperature for 30 minutes. | - |
| 8. Environment test / | Salt spray test | Temperature: 35 2 Solution: 5 1% Spray time: 24hours Wash and dry it at room temperature after the experiment. | No obvious rust in the appearance. |
| 9. Test condition / | Standard test conditions | Temperature: 15C~35C, Relative humidity: 25%~85%, Atmospheric pressure: 86kPa~106kPa. For doubtful judgments: 201C, 63%~67% RH, 86kPa~106kPa. | - |
| 10. Amendment / | Specification Amendment | Negotiated and agreed by the manufacturer and the customer. | - |
2411220203_JINJIA-XLR-04P-3_C558738.pdf